Schneider LC1F150E7 - TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 150 A - coil 115 V AC
Schneider

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 150 A - coil 115 V AC

Nicht im Verkauf

Schneider LC1F150E7, TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 150 A - coil 115 V AC. Kategorie: TeSys F. Nicht im Verkauf; für dieses Produkt gibt es keinen Preis und kein Angebot.

Wichtige Eigenschaften

Range
TeSys
Range Of Product
TeSys F
Product Or Component Type
Schütz
Device Short Name
LC1F

Produktbeschreibung

Tesys F Schütz - 3P (3 Schließer) - AC-3 - <= 440 V 250 A - Spule 48 V AC

Technische Daten

Haupteigenschaften10
RangeTeSys
Range Of ProductTeSys F
Product Or Component TypeSchütz
Device Short NameLC1F
Contactor ApplicationMotor control; Resistive load
Utilisation CategoryAC-1; AC-4; AC-3
Poles Description3P
[Ue] Rated Operational Voltage<= 690 V AC 50/60 Hz; <= 460 V DC
[Uc] Control Circuit Voltage48 V AC 40...400 Hz
[Ie] Rated Operational Current250 A (at <40 °C) at <= 440 V AC-1; 150 A (at <55 °C) at <= 440 V AC-3
Ergänzende Eigenschaften25
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ith] Conventional Free Air Thermal Current250 A (at 40 °C)
Rated Breaking Capacity1200 A conforming to IEC 60947-4-1
[Icw] Rated Short-time Withstand Current1200 A 40 °C - 10 s; 700 A 40 °C - 30 s; 600 A 40 °C - 1 min; 450 A 40 °C - 3 min; 350 A 40 °C - 10 min
Associated Fuse Rating160 A aM at <= 440 V; 250 A gG at <= 440 V
Average Impedance0.35 mOhm - Ith 250 A 50 Hz
[Ui] Rated Insulation Voltage1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C
Power Dissipation Per Pole22 W AC-1; 8 W AC-3
Overvoltage CategoryIII
Power Pole Contact Composition3 NO
Motor Power KW75 kW at 380...400 V AC 50/60 Hz (AC-3); 80 kW at 415 V AC 50/60 Hz (AC-3); 80 kW at 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660...690 V AC 50/60 Hz (AC-3); 40 kW at 220...230 V AC 50/60 Hz (AC-3); 22 kW at 400 V AC 50/60 Hz (AC-4)
Control Circuit Voltage LimitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C); Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
Mechanical Durability10 Mcycles
Inrush Power In VA770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in Power Consumption In VA8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum Operating Rate2400 cyc/h 55 °C
Operating Time35 ms closing (at Uc); 130 ms opening (at Uc)
Connections - TerminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid w
Tightening TorqueControl circuit: 1.2 N.m; Power circuit: 18 N.m
Mounting SupportPlate
Heat Dissipation5.9…7.2 W
StandardsEN 60947-1; EN 60947-4-1; IEC 60947-1; IEC 60947-4-1; JIS C8201-4-1
Product CertificationsRMRoS; DNV; BV; CCC; CB; RINA; ABS; LROS (Lloyds register of shipping); UL; UKCA
Compatibility CodeLC1F
Control Circuit TypeAC at 40...400 Hz
Umgebungsbedingungen10
IP Degree Of ProtectionIP2X front face with shrouds conforming to IEC 60529; IP2X front face with shrouds conforming to VDE 0106
Protective TreatmentTH
Ambient Air Temperature For Operation-40…60 °C
Ambient Air Temperature For Storage-60…80 °C
Permissible Ambient Air Temperature Around The Device60…70 °C at Uc
Height170 mm
Width163.5 mm
Depth171 mm
Operating Altitude3000 m without derating
Net Weight3.43 kg
Verpackungseinheiten6
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height21.0 cm
Package 1 Width20.0 cm
Package 1 Length24.0 cm
Package 1 Weight4.147 kg
Logistical informations1
Country Of OriginCZ

Dokumente und Downloads

Die Dokumente werden vom Hersteller veröffentlicht und in einem neuen Tab geöffnet.

Weitere Dokumente2

Schlagwörter

Produkte mit demselben Schlagwort im Katalog ansehen.

Direkter WhatsApp-Support