Schneider
TeSys Deca - star delta starter - 3 x 3P (3 NO) - 9 A - 380 V AC coil

Nicht im Verkauf
Schneider LC3D09AQ7, TeSys Deca - star delta starter - 3 x 3P (3 NO) - 9 A - 380 V AC coil. Kategorie: Stern-Dreieck-Schütz. Nicht im Verkauf; für dieses Produkt gibt es keinen Preis und kein Angebot.
- Referenz:LC3D09AQ7
- Hersteller / Marke:Schneider
Wichtige Eigenschaften
- Range
- TeSys
- Produktname
- TeSys D
- Product Or Component Type
- Star delta starter
- Device Short Name
- LC3D
Produktbeschreibung
Stern-Dreieck-Kombination auf Montageplatte TeSys Lc3-d - Spule 380 V AC
Technische Daten
Haupteigenschaften24
| Range | TeSys |
|---|---|
| Produktname | TeSys D |
| Product Or Component Type | Star delta starter |
| Device Short Name | LC3D |
| Contactor Application | Motor control |
| Utilisation Category | AC-3 |
| Device Presentation | Pre-wired |
| Poles Description | 3 x 3P |
| Power Pole Contact Composition | 3 x 3 NO |
| [Ue] Rated Operational Voltage | Power circuit: <= 690 V AC 25...400 Hz |
| [Ie] Rated Operational Current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Motor Power KW | 4 kW at 220/230 V AC 50/60 Hz; 7.5 kW at 380/400 V AC 50/60 Hz; 7.5 kW at 415 V AC 50/60 Hz; 7.5 kW at 440 V AC 50/60 Hz |
| Control Circuit Type | AC at 50/60 Hz |
| [Uc] Control Circuit Voltage | 380 V AC 50/60 Hz |
| Auxiliary Contact Composition | 1 NC for KM1 star contactor |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Overvoltage Category | III |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Electrical Durability | 2 Mcycles 9 A AC-3 at Ue <= 440 V |
| Safety Cover | Protective cover |
| Interlocking Type | Mechanical |
| Mounting Support | Plate |
| Standards | EN 60947-5-1; IEC 60947-4-1; EN 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 508 |
| Product Certifications | LROS (Lloyds register of shipping); UL; GOST; DNV; CCC; GL; CSA; RINA; BV |
Ergänzende Eigenschaften19
| Connections - Terminals | Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Power circuit: screw clamp t |
|---|---|
| Tightening Torque | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Mechanical Durability | 15 Mcycles |
| Maximum Operating Rate | 30 cyc/h 60 °C |
| Starting Time | 30 s |
| Coil Technology | Without built-in suppressor module |
| Control Circuit Voltage Limits | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C); Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C); Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C) |
| Inrush Power In VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in Power Consumption In VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat Dissipation | 2…3 W at 50/60 Hz |
| Auxiliary Contacts Type | Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC; Mirror contact conforming to IEC 60947-4-1 3 x 1 NC |
| Signalling Circuit Frequency | 25...400 Hz |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Non-overlap Time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Width | 143 mm |
| Height | 124 mm |
| Depth | 143 mm |
| Net Weight | 1.53 kg |
Umgebungsbedingungen11
| Insulation Resistance | > 10 MOhm for signalling circuit |
|---|---|
| IP Degree Of Protection | IP20 front face conforming to IEC 60529 |
| Climatic Withstand | conforming to IACS E10; conforming to IEC 60947-1 Annex Q category D |
| Protective Treatment | TH conforming to IEC 60068-2-30 |
| Pollution Degree | 3 |
| Ambient Air Temperature For Storage | -60…80 °C |
| Ambient Air Temperature For Operation | -40…70 °C at Uc |
| Operating Altitude | 3000 m without derating |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations contactor open: 2 Gn, 5...300 Hz; Vibrations contactor closed: 4 Gn, 5...300 Hz; Shocks contactor open: 10 Gn for 11 ms; Shocks contactor closed: 15 Gn for 11 ms |
Verpackungseinheiten6
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 18 cm |
| Package 1 Width | 16 cm |
| Package 1 Length | 23.5 cm |