Telemecanique Sensors XMLP060BD21V - Pressure sensor, XMLP, pressure range 60 bar, output 4-20 mA, G1/4A male, M12 connector, Viton seal
Telemecanique Sensors

Pressure sensor, XMLP, pressure range 60 bar, output 4-20 mA, G1/4A male, M12 connector, Viton seal

Nicht im Verkauf

Telemecanique Sensors XMLP060BD21V, Pressure sensor, XMLP, pressure range 60 bar, output 4-20 mA, G1/4A male, M12 connector, Viton seal. Kategorie: Ausgang 4...20mA. Nicht im Verkauf; für dieses Produkt gibt es keinen Preis und kein Angebot.

Wichtige Eigenschaften

Range Of Product
Telemecanique Pressure sensors XM
Product Or Component Type
Electronic pressure sensors
Pressure Sensor Type
Pressure transmitter
Pressure Sensor Name
XMLP

Produktbeschreibung

Basınç İleticisi - Xmlp - 60bar - G1/4a Erkek - 4..20ma - M12 - 1'li Set

Technische Daten

Haupteigenschaften14
Range Of ProductTelemecanique Pressure sensors XM
Product Or Component TypeElectronic pressure sensors
Pressure Sensor TypePressure transmitter
Pressure Sensor NameXMLP
Fluid Connection TypeG 1/4A (male) conforming to DIN 3852-E
Electrical Circuit TypeControl circuit
Electrical Connection1 male connector M12 4 pins
Type Of Output SignalAnalogue
[Us] Rated Supply Voltage12...24 V DC SELV (voltage limits: 8-30 V)
Analogue Output Function4...20 mA, 2-wire
Quantity Per SetSet of 1
Type Of PackingIndividual
Materials In Contact With FluidFluorocarbon FKM (Viton), stainless steel type 17-4PH, stainless steel type AISI 304
Scale TypeFixed differential
Ergänzende Eigenschaften11
Controlled FluidAir (-20-120 °C), fresh water (0-120 °C), hydraulic oil (-20-120 °C), gas (-20-120 °C), refrigeration fluid (-20-120 °C)
Local DisplayWithout
Current Consumption20 mA
Electromagnetic CompatibilitySusceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV
Protection TypeLoad short-circuit, reverse polarity
Response Time On Output< 5 ms 92 % of full scale
AccuracyInfinity
Drift Of The Sensitivity+/- 0,02 % of measuring range/°K
Drift Of The Zero Point+/- 0,02 % of measuring range/°K
Repeat Accuracy+/- 0,2 % de la plage de mesure
Measurement Accuracy+/- 0,5 % de la plage de mesure
Umgebungsbedingungen7
Operating PositionAny position
StandardsCE, EN/IEC 61326-1
Product CertificationscULus, RCM
Protective TreatmentTC
Vibration Resistance20 gn (f = 10-2000 Hz) conforming to EN/IEC 60068-2-64
Shock Resistance25 gn for 11 ms conforming to IEC 60068-2-27
IP Degree Of ProtectionIP65 conforming to IEC 60529, IP67 conforming to IEC 60529, IP69K conforming to DIN 40050
Verpackungseinheiten2
Unit Type Of Package 1piece
Number Of Units In Package 11
Nachhaltigkeit des Angebots1
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. Fo more information go to www.P65Warnings.ca.gov