28928 - ComPacT, yellow-red, safety switch-disconnector, INS160
Schneider 28928, ComPacT, yellow-red, safety switch-disconnector, INS160. Category: Compact INS/INV. Request a quote for price and lead time.
- Reference:28928
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:173.00 EUR (Request a quote)
Key Specifications
- Range
- ComPact
- Product Name
- ComPacT INS
- Product Or Component Type
- Switch disconnector
- Poles Description
- 3P
Product Description
This Compact INS160 is a 3 poles non-automatic switch-disconnector with red rotary handle and yellow front. It is suitable for isolation with positive contact indication, as defined by IEC 60947-1 and IEC60947-3 standards. The operational current is 160A at 415VAC in categories AC22A and AC23A. The rated voltage is 690VAC 50/60Hz or 250VDC. It can be used as an emergency-off device. For easy identification, it uses special colours stipulated by the standards. The red rotary handle is designed to offer easy operation and high performance in interruption of currents. Compact INS160 is a class II insulation level front-face device as per IEC 60664 standard.
Key Features
- "Schneider Electric green signature style for the entire ComPacT range"
- "Estimated 40% reduction of wiring time for panel builders"
- "Experience easier installation thanks to a new ergonomic front-plate design"
- "Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating"
- "Ergonomic new toggle for easier breaker manual operation"
Technical Specifications
Main16
| Range | ComPact |
|---|---|
| Product Name | ComPacT INS |
| Product Or Component Type | Switch disconnector |
| Poles Description | 3P |
| Network Type | AC; DC |
| Network Frequency | 50/60 Hz |
| [Ie] Rated Operational Current | AC-22A: 160 A AC 50/60 Hz 220/240 V; AC-22A: 160 A AC 50/60 Hz 380/415 V; AC-22A: 160 A AC 50/60 Hz 440/480 V; AC-22A: 160 A AC 50/60 Hz 500 V; AC-22A: 160 A AC 50/60 Hz 660/690 V; AC-23A: 100 A AC 50/60 Hz 660/690 V; AC-23A: 160 A AC 50/60 Hz 220/240 V; AC-23A: 160 A AC 50/60 Hz 380/415 V; AC-23A: 160 A AC 50/60 Hz 440/480 V; AC-23A: 160 A AC 50/60 Hz 500 V; DC-22A: 160 A DC 125 V 2 poles in seri |
| [Ui] Rated Insulation Voltage | 800 V AC 50/60 Hz |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| [Ith] Conventional Free Air Thermal Current | 160 A at 60 °C |
| [Icm] Rated Short-circuit Making Capacity | 154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz; 20 kA switch-disconnector alone 690 V AC at 50/60 Hz |
| [Ue] Rated Operational Voltage | 125 V DC; 690 V AC 50/60 Hz |
| Suitability For Isolation | Yes |
| Contact Position Indicator | Yes |
| Visible Break | No |
| Pollution Degree | 3 |
Complementary17
| Control Type | Rotary handle |
|---|---|
| Handle Colour | Red |
| Mounting Mode | Fixed |
| Mounting Support | Plate; DIN rail |
| Upside Connection | Front |
| Downside Connection | Front |
| Maximum Power | AC-23: 110 kW at 500/525 V AC 50/60 Hz; AC-23: 45 kW at 220/240 V AC 50/60 Hz; AC-23: 75 kW at 380/415 V AC 50/60 Hz; AC-23: 90 kW at 440 V AC 50/60 Hz; AC-23: 90 kW at 660/690 V AC 50/60 Hz |
| Rated Duty | Uninterrupted |
| Intermittent Duty Class | Class 120 - 60 % |
| [Icw] Rated Short-time Withstand Current | 1 kA during 30 s conforming to IEC 60947-3; 1.23 kA during 20 s conforming to IEC 60947-3; 3.175 kA during 3 s conforming to IEC 60947-3; 5.5 kA during 1 s conforming to IEC 60947-3 |
| Mechanical Durability | 15000 cycles |
| Electrical Durability | AC-22A: 1500 cycles 220/240 V AC 50/60 Hz; AC-22A: 1500 cycles 380/415 V AC 50/60 Hz; AC-22A: 1500 cycles 440 V AC 50/60 Hz; AC-22A: 1500 cycles 500 V AC 50/60 Hz; AC-23A: 1500 cycles 220/240 V AC 50/60 Hz; AC-23A: 1500 cycles 380/415 V AC 50/60 Hz; AC-23A: 1500 cycles 440 V AC 50/60 Hz; AC-23A: 1500 cycles 500 V AC 50/60 Hz; DC-22A: 1500 cycles 250 V DC 2 poles in series; DC-23A: 1500 cycles 250 |
| Connection Pitch | 30 mm |
| Height | 100 mm |
| Width | 135 mm |
| Depth | 62.5 mm |
| Net Weight | 0.8 kg |
Environment6
| Standards | IEC 60947-3; IEC 60947-1 |
|---|---|
| Product Certifications | CCC; KEMA-KEUR |
| IP Degree Of Protection | IP40 conforming to IEC 60529 |
| IK Degree Of Protection | IK07 conforming to EN 50102 |
| Ambient Air Temperature For Operation | -25…70 °C |
| Ambient Air Temperature For Storage | -50…85 °C |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 13.000 cm |
| Package 1 Width | 11.200 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 1.045 kg |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 10 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.552 kg |
Logistical informations1
| Country Of Origin | PL |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.