Schneider A9C65310 - Reflex iC60H Ti24 10 A 3P curve C integrated control MCB
Schneider

Reflex iC60H Ti24 10 A 3P curve C integrated control MCB

Not for sale

Schneider A9C65310, Reflex iC60H Ti24 10 A 3P curve C integrated control MCB. Category: Reflex iC60. Not for sale; no price or quote is offered for this product.

Key Specifications

Device Application
Control; Distribution
Range
Acti9
Product Name
Reflex iC60
Device Short Name
Reflex iC60H

Product Description

This Acti 9 Reflex iC60H is a low voltage integrated control circuit breaker. It combines integrated circuit breaker protection and load control for lighting control applications. It has 3P with 3 protected poles, rated current 10A and C tripping curve. Y1/Y2 inputs remote control voltage is 230VAC and 1A. They allow local and remote control of lighting. Y3 input remote control voltage is 24VDC and 5.5mA. Y3 allow easy connection to a Power Logic Controller or a Building Management System. Breaking capacity at 230VAC is 30kA according to IEC 60947-2 . Breaking capacity at 400VAC is 15kA according to IEC 60974-2. Electrical endurance goes up to 30000 cycles for AC-1 or AC-7a. Electrical endurance goes up to 6000 cycles for AC-5a or AC-5b and AC-7c. It is possible to associate a vigi block to have a differential protection.

Technical Specifications

Main10
Device ApplicationControl; Distribution
RangeActi9
Product NameReflex iC60
Device Short NameReflex iC60H
Product Or Component TypeIntegrated control circuit breaker
Poles Description3P
Number Of Protected Poles3
Network TypeAC
Trip Unit TechnologyThermal-magnetic
Curve CodeC
Complementary24
[In] Rated Current10 A
Network Frequency50/60 Hz
Breaking Capacity CodeH
Breaking Capacity30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC
Contact Position IndicatorYes
Control TypeRemote control by continuous command; Remote control by pulse; Toggle; ON/OFF button
Control Signal TypeImpulse; Maintained; Maintained very low voltage
Local SignallingGreen LED: device ON; Flashing LED: device tripped; Red LED: fault; Flashing LED: device ready; Flashing LED: device overheat
[Uc] Control Circuit Voltage230 V AC 50/60 Hz; 24 V AC 50/60 Hz; 48 V AC 50/60 Hz; 24 V DC; 48 V DC
[Us] Rated Supply Voltage230 V AC at 50/60 Hz
Mounting ModeFixed
Mounting Support35 mm symmetrical DIN rail
9 Mm Pitches11
Height84 mm
Width99 mm
Depth77 mm
ColourWhite
Mechanical Durability50000 cycles
Electrical DurabilityAC-1: 50000 cycles AC 50 Hz
Provision For PadlockingPadlockable
Locking Options DescriptionPadlock in OFF position
Earth-leakage ProtectionSeparate block
Product CompatibilityWith PLC
Environment4
IP Degree Of ProtectionIP20 conforming to IEC 60529
Pollution Degree3
Tropicalisation2
Relative Humidity93 % at 40 °C
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height9 cm
Package 1 Width11.4 cm
Package 1 Length16.8 cm
Package 1 Weight678 g
Unit Type Of Package 2S03
Number Of Units In Package 214
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.972 kg
Logistical informations1
Country Of OriginES
Contractual warranty1
Warranty (in Months)18

Documents and Downloads