Schneider A9D34640 - iDPN Vigi 1P + N 40A 4.5 kA C CURVE 30mA
Schneider

A9D34640 - iDPN Vigi 1P + N 40A 4.5 kA C CURVE 30mA

Schneider A9D34640, iDPN Vigi 1P + N 40A 4.5 kA C CURVE 30mA. Category: iDPN Vigi RCBO. Request a quote for price and lead time.

Key Specifications

Range
Acti9
Product Name
Acti9 iDPN Vigi
Device Short Name
iDPNa Vigi
Device Application
Distribution

Product Description

This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 40A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 4500A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. It also has a fault tripping indication on the front panel by the position of the handle (O-I engraved). This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.

Key Features

  • Unique new white finish for a fresh modern look
  • Suitability for isolation according to IEC/EN 61009-1 and IEC/EN 61009-2-1 standards
  • Provides protection for final circuits against overcurrents and short-circuits
  • Earth-leakage sensitivity of 30mA ensures protection of persons against electric shock from direct contact
  • Easy to install with unified terminal design and wiring indication

Technical Specifications

Main15
RangeActi9
Product NameActi9 iDPN Vigi
Product Or Component TypeResidual current breaker with overcurrent protection (RCBO)
Device Short NameiDPNa Vigi
Device ApplicationDistribution
Poles Description1P + N
Number Of Protected Poles1
Neutral PositionLeft
[In] Rated Current40 A
Network TypeAC
Network Frequency50 Hz
Trip Unit TechnologyThermal-magnetic
Curve CodeC
Earth-leakage Sensitivity30 mA
Suitability For IsolationYes conforming to EN/IEC 60947-2
Complementary32
Device Location In SystemOutgoer
[Ue] Rated Operational Voltage230...240 V AC 50 Hz
Magnetic Tripping Limit5...10 x In
Residual Current Tripping TechnologyVoltage independent
Earth-leakage Protection Time DelayInstantaneous
Earth-leakage Protection ClassType AC
Breaking Capacity4500 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
[Ics] Rated Service Breaking Capacity4500 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated Breaking And Making CapacityIdm 4500 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation Class3 conforming to EN/IEC 61009-2-1
[Ui] Rated Insulation Voltage400 V AC 50 Hz
[Uimp] Rated Impulse Withstand Voltage4 kV
Contact Position IndicatorYes
Control TypeToggle
Local SignallingON, OFF, fault trip
Mounting ModeClip-on
Mounting SupportDIN rail
Comb Busbar And Distribution Block CompatibilityTop or bottom: YES
Connection Pitch9 mm between phase and neutral
9 Mm Pitches4
Height85 mm
Width36 mm
Depth73 mm
Net Weight125 g
ColourWhite
Mechanical Durability20000 cycles
Electrical Durability10000 cycles
Locking Options DescriptionPadlocking device
Connections - TerminalsSingle terminal top or bottom 1…16 mm² rigid; Single terminal top or bottom 1…10 mm² flexible; Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire Stripping Length15 mm for top or bottom connection
Tightening Torque2 N.m top or bottom
Earth-leakage ProtectionIntegrated
Environment10
StandardsEN/IEC 61009-2-1; EN/IEC 61009-1
Product CertificationsVDE
IP Degree Of ProtectionIP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree3
Overvoltage CategoryIII conforming to IEC 60364
Electromagnetic Compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative Humidity95 % at 55 °C
Ambient Air Temperature For Operation-5…60 °C
Ambient Air Temperature For Storage-40…85 °C
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height7.800 cm
Package 1 Width4.000 cm
Package 1 Length10.000 cm
Package 1 Weight227.000 g
Unit Type Of Package 2S03
Number Of Units In Package 254
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight13.238 kg
Logistical informations1
Country Of OriginES
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support