A9R14492 - Acti9 RCCB-ID 4P 125A 300mA AC type NEW (replaces 16907)
Schneider A9R14492, Acti9 RCCB-ID 4P 125A 300mA AC type NEW (replaces 16907). Category: Acti9 RCCB-ID 125A. Request a quote for price and lead time.
- Reference:A9R14492
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:536.00 EUR (Request a quote)
Key Specifications
- Range
- Acti9
- Product Name
- Acti9 RCCB-ID
- Product Or Component Type
- Residual current circuit breaker (RCCB)
- Device Short Name
- RCCB-ID
Product Description
This Acti9 RCCB-ID product is a residual current circuit breaker (RCCB). It is a 4P residual current circuit breaker with 125A In rated current, 300mA earth leakage sensitivity and AC type protection class. It can be padlockable in OFF position by addition of a padlocking accessory. It is compatible only with 4P PowerTag Energy. This product protects against electrical shock by indirect contact and against the risk of fire. This AC type residual current circuit breaker detects residual sinusoidal alternating current. It is suitable for general use and generally covers most of the applications. The tripping technology is voltage independent. The earth-leakage protection time delay is instantaneous, ensuring instantaneous tripping without time delay. The status of the product is indicated via the 3 position toggle and a front panel indicator : open with green indicator, closed with red indicator, tripped in fault with green indicator. This Acti9 RCCB ensures protection in all small industrial and tertiary buildings. This product is compliant with IEC/EN 60947-1 and -3, IEC/EN 61008-1 and -2-1 standards. It has the VDE and CE quality labels. The (Im/IΔm) rated breaking and making short circuit capacity is 1250A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The electrical endurance is up to 2000 cycles. The mechanical endurance is up to 5000 cycles. The Ue operational voltage is 400VAC at a frequency of 50Hz. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. It is DIN rail mountable. The width in 9mm pitch is 8. The product colour is grey. The dimensions are (W) 72mm x (H) 86mm x (D) 76mm. The weight is 420g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 85°C.
Key Features
- Part of Acti9 system
- Compliant with IEC/EN61008-2-1 standard
- Protection of people against electric shocks by indirect contact
- Protection of installations against risks of fire
- Easy to install with unified terminal design and wiring indication
Technical Specifications
Main13
| Range | Acti9 |
|---|---|
| Product Name | Acti9 RCCB-ID |
| Product Or Component Type | Residual current circuit breaker (RCCB) |
| Device Short Name | RCCB-ID |
| Poles Description | 4P |
| Neutral Position | Left |
| [In] Rated Current | 125 A |
| Network Type | AC |
| Earth-leakage Sensitivity | 300 mA |
| Earth-leakage Protection Time Delay | Instantaneous |
| Earth-leakage Protection Class | Type AC |
| Rated Breaking And Making Capacity | Im = 1250 A 400 V conforming to IEC/EN 61008-1; Im = 1250 A 230 V conforming to IEC/EN 61008-2-1 |
| Rated Conditional Short-circuit Current | Inc 10 kA 125 A |
Complementary24
| Device Location In System | Outgoer |
|---|---|
| Network Frequency | 50 Hz |
| [Ue] Rated Operational Voltage | 400 V AC 50 Hz conforming to IEC/EN 61008-1; 400 V AC 50 Hz conforming to IEC/EN 61008-2-1 |
| Residual Current Tripping Technology | Voltage independent |
| [Ui] Rated Insulation Voltage | 400 V AC 50 Hz conforming to IEC/EN 61008-1; 400 V AC 50 Hz conforming to IEC/EN 61008-2-1 |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV conforming to IEC/EN 61008-1; 4 kV conforming to IEC/EN 61008-2-1 |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Local Signalling | Red/green indicator; Trip indicator |
| Mounting Mode | Fixed |
| Mounting Support | 35 mm symmetrical DIN rail |
| Connection Pitch | 18 mm between phases |
| 9 Mm Pitches | 8 |
| Height | 86 mm |
| Width | 72 mm |
| Depth | 76 mm |
| Net Weight | 420 g |
| Colour | Grey |
| Mechanical Durability | 5000 cycles |
| Electrical Durability | 2000 cycles |
| Provision For Padlocking | Padlockable |
| Connections - Terminals | Tunnel type terminals2 cable(s) 1.5…16 mm² flexible; Tunnel type terminals2 cable(s) 1.5…16 mm² rigid; Tunnel type terminals1 cable(s) 1.5…50 mm² rigid; Tunnel type terminals1 cable(s) 1.5…35 mm² flexible; Tunnel type terminals1 cable(s) 1.5…35 mm² flexible with ferrule; Tunnel type terminals2 cable(s) 1.5…16 mm² flexible with ferrule |
| Wire Stripping Length | 11 mm |
| Tightening Torque | 3 N.m |
Environment8
| Standards | IEC/EN 61008-1; IEC/EN 61008-2-1 |
|---|---|
| Product Certifications | CE |
| Quality Labels | VDE |
| IP Degree Of Protection | IP20 conforming to IEC/EN 60529; IP40 (modular enclosure) conforming to IEC/EN 60529 |
| Pollution Degree | 3 |
| Electromagnetic Compatibility | 8/20 µs impulse withstand, 250 A conforming to IEC/EN 61008-1; 8/20 µs impulse withstand, 250 A conforming to IEC/EN 61008-2-1 |
| Ambient Air Temperature For Operation | -25…40 °C |
| Ambient Air Temperature For Storage | -40…85 °C |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 8.000 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.000 cm |
| Package 1 Weight | 417.000 g |
| Unit Type Of Package 2 | S02 |
| Number Of Units In Package 2 | 12 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.319 kg |
Logistical informations1
| Country Of Origin | DE |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads