Acti9 iID - RCCB - 4P - 40A - 300mA s - type AC
Schneider A9R15440, Acti9 iID - RCCB - 4P - 40A - 300mA s - type AC. Category: iID RCCB. In stock.
- Reference:A9R15440
- Manufacturer / Brand:Schneider
- Availability:In stock (5 pcs) ✅
- Price:144.10 EUR (Request a quote)
Key Specifications
- Range
- Acti9
- Product Name
- Acti9 iID
- Product Or Component Type
- Residual current circuit breaker (RCCB)
- Device Short Name
- iID
Product Description
This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, a sensitivity of 300mA with a AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance. This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 15000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 91mm x (D) 73.5mm. The weight is 0.37kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
Key Features
- Protection of persons against electric shock by indirect contact
- Suitability for residential isolation according to IEC 61008-1 and IEC 61008-2-1 standards
- Protection of installations against the risk of fire
- Easy to install with unified terminal design and wiring indication
- Earth fault indication by a red mechanical indicator in front face
Technical Specifications
Main11
| Range | Acti9 |
|---|---|
| Product Name | Acti9 iID |
| Product Or Component Type | Residual current circuit breaker (RCCB) |
| Device Short Name | iID |
| Poles Description | 4P |
| Neutral Position | Left |
| [In] Rated Current | 40 A |
| Network Type | AC |
| Earth-leakage Sensitivity | 300 mA |
| Earth-leakage Protection Time Delay | Selective |
| Earth-leakage Protection Class | Type AC |
Complementary25
| Device Location In System | Outgoer |
|---|---|
| Network Frequency | 50/60 Hz |
| [Ue] Rated Operational Voltage | 400...415 V AC 50/60 Hz |
| Residual Current Tripping Technology | Voltage independent |
| Rated Breaking And Making Capacity | Idm 1500 A; Im 1500 A |
| Rated Conditional Short-circuit Current | 10 kA |
| [Ui] Rated Insulation Voltage | 500 V AC 50/60 Hz |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Mounting Mode | Clip-on |
| Mounting Support | 35 mm DIN rail |
| 9 Mm Pitches | 8 |
| Height | 85 mm |
| Width | 72 mm |
| Depth | 69 mm |
| Embedding Depth | 44 mm |
| Net Weight | 370 g |
| Colour | White (RAL 9003) |
| Mechanical Durability | 20000 cycles |
| Electrical Durability | 15000 cycles |
| Locking Options Description | Padlocking device |
| Connections - Terminals | Single terminal top or bottom 1…35 mm² rigid; Single terminal top or bottom 1…25 mm² flexible; Single terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire Stripping Length | 14 mm for top or bottom connection |
| Tightening Torque | 3.5 N.m top or bottom |
Environment6
| Standards | EN/IEC 61008-1; EN/IEC 61008-2-1 |
|---|---|
| IP Degree Of Protection | IP20 conforming to IEC 60529; IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution Degree | 3 |
| Electromagnetic Compatibility | 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1 |
| Ambient Air Temperature For Operation | -5…60 °C |
| Ambient Air Temperature For Storage | -40…85 °C |
Packing Units18
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 7.600 cm |
| Package 1 Width | 8.400 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 351.000 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 27 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.369 kg |
| Unit Type Of Package 3 | P12 |
| Number Of Units In Package 3 | 216 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 82.952 kg |
Logistical informations1
| Country Of Origin | ES |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads