Schneider ATS130N2D45LT - Altivar Soft Starter ATS130 45A 200 to 480V
Schneider

ATS130N2D45LT - Altivar Soft Starter ATS130 45A 200 to 480V

Schneider ATS130N2D45LT, Altivar Soft Starter ATS130 45A 200 to 480V. Category: Altivar Soft Starter ATS130. Request a quote for price and lead time.

Key Specifications

Range Of Product
Altivar Soft Starter ATS130
Product Or Component Type
Soft starter
Product Destination
Asynchronous motors
Product Specific Application
Simple machine

Product Description

  • "This soft starter belongs to the Altivar Soft Starter ATS130 range that is intended to start and stop asynchronous motors supplied from 200 to 480V."
  • With an operational rated current of 45A in normal duty, it supplies motor from 11 to 22kW according to mains voltage.
  • "Compact, it provides mechanical and electrical flexibility in control panel design."
  • ATS130 is preventive maintenance free and allows optimized motor management especially in combination with TeSys Deca motor circuit breaker.
  • It is designed with Everlink power terminals and spring control terminals that avoid annual wire retightening.
  • This soft starter has the same width (55mm) as the TeSys Deca frame 3 motor circuit breaker; it allows the building of the ATS130 Soft Motor Starter.
  • Its dimensions are 55mm (width) x 165mm (depth) x 179mm (height), and it weighs 1.26kg.
  • Altivar Soft Starter ATS130 is designed to address pumps, fans, compressors, conveyors, and other simple machines.
  • It conforms to the IEC/EN60947-4-1 standard and has received the CE, EAC, UKCA, CCC, and RCM certifications.
  • It is possible to add a fixing kit to mount the TeSys Deca frame 3 motor circuit breaker on top of ATS130 or a cooling fan to extend the number of starts per hour.
  • The ATS130 soft starters can be mounted on a backplate or on a DIN rail, side by side, and they are compatible with a 200mm depth cabinet.
  • "The Altivar Soft Starter ATS130 range is preventive maintenance-free and increases operational efficiency during design, manufacturing, and commissioning."
  • product designed to take the environmental considerations beyond current directives and regulations, compliant with RoHS and REACH.

Key Features

  • "Allows design optimization and time savings"
  • "Optimized motor management (with TeSys Deca motor circuit breaker)"
  • "Preventive maintenance free"
  • "Increase operational efficiency during mounting and wiring"
  • "High starting capability as standard that could be extended"

Technical Specifications

Main15
Range Of ProductAltivar Soft Starter ATS130
Product Or Component TypeSoft starter
Product DestinationAsynchronous motors
Product Specific ApplicationSimple machine
Device Short NameATS130
Network Number Of Phases3 phases
Utilisation CategoryAC-53A
Ue Power Supply Voltage200...480 V - 15...10 %
Power Supply Frequency50...60 Hz +/- 5 Hz
[Ie] Rated Operational Current45 A in line (at <40 °C)
Service Factor At Ie100
Torque ControlFalse
IP Degree Of ProtectionIP20
Motor Power KW11 kW at 230 V normal duty; 22 kW at 400 V normal duty; 22 kW at 440 V normal duty
Motor Power Hp10 hp at 200 V normal duty; 10 hp at 208 V normal duty; 15 hp at 230 V normal duty; 30 hp at 460 V normal duty; 30 hp at 480 V normal duty
Complementary38
Overload Current Profile300 % Ie for 5 s
On-load Factor70 %
Operating Cycles/hour35 cyc/h
Minimum Motor Current20 % Ie
Device ConnectionIn line
[Us] Control Circuit Voltage24 V DC +/- 10 %
Control Power21.6 W starting and stopping; 3 W steady state
Integrated Motor Overload ProtectionFalse
Protection TypePhase failure: mains; Thermal protection: starter; Bypass error: starter; Control voltage Us: starter
Rated Current Pwr Loss Specification45 A
Power Loss Static Current Independent3 W
Power Loss Per Device Current Dependent9 W
Power Loss During Starting264 W 300 % Ie
StandardsEN/IEC 60947-4-2; UL 60947-4-2; IEC 60664-1
Product CertificationsCE; UKCA; CCC; RCM; EAC; UL
MarkingCE; CCC; UKCA; RCM; EAC
[Uc] Control Circuit Voltage24 V DC
Discrete Input Number3
Discrete Input Type(DI) digital input, 10 kOhm; (DI2) digital input, 10 kOhm; (BOOST) digital input, 10 kOhm
Input CompatibilityDiscrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete Input LogicDigital input at State 0: 0... 13 V, >= 0.5 mA
Relay Output Number1
Relay Output TypeRelay outputs R1A, R1C NO
Minimum Switching Current2.5 mA at 24 V DC for relay outputs
Maximum Switching CurrentOn resistive load for relay outputs : 1 A 250 V AC 400000 cycles; On resistive load for relay outputs : 1 A 30 V DC 400000 cycles; On inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles; On inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles
Discrete Output Number1
Discrete Output TypeNon programmable digital output DQ1 <= 30 V 200 mA
Display Type1 LED (green) for control power energized; 1 LED (yellow and red) for motor operation phases, errors
Display Screen AvailableFalse
Operating PositionVertical +/- 30 degree
Height166 mm
Width55 mm
Depth165 mm
Net Weight1.3 kg
Suitable For Mounting Onto Standard RailsTrue
Function AvailableDeceleration voltage ramp; Boost
Internal BypassTrue
Material DeclarationTrue
Environment19
Pollution DegreeLevel 2
Environmental Class (during Operation)Without salt mist: 3C3 conforming to IEC 60721-3-3; 3S3 conforming to IEC 60721-3-3
[Uimp] Rated Impulse Withstand Voltage4 kV
[Ui] Rated Insulation Voltage480 V
Electromagnetic CompatibilityConducted and radiated emissions level B conforming to IEC 60947-4-2; Short voltage interruptions level 3 conforming to IEC 61000-4-11; Electrostatic discharge level 2 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4; Oscillatory waves immu
Ambient Air Temperature For Operation-10…40 °C (without derating); 40…60 °C (with current derating 1.5 % per °C)
Ambient Air Temperature For Storage-25…70 °C
Ambient Air Transport Temperature-40…70 °C
Operating Altitude0...1000 m without derating; 1000...4000 m 1 % per 100 m
Relative Humidity5…95 % non condensing without dripping water conforming to IEC 60068-2-3
Maximum Acceleration Under Vibrational Stress (during Operation)10 m/s² at 9...200 Hz
Maximum Acceleration Under Vibratory Load (during Storage)10 m/s² at 9...200 Hz
Maximum Acceleration Under Vibratory Load (during Transport)10 m/s² at 9...200 Hz
Maximum Deflection Under Vibratory Load (during Operation)3 mm at 2-9 Hz
Maximum Deflection Under Vibratory Load (during Storage)3 mm at 2-9 Hz
Maximum Deflection Under Vibratory Load (during Transport)3 mm at 2-9 Hz
Maximum Acceleration Under Shock Impact (during Operation)100 m/s² at 11 ms
Maximum Acceleration Under Shock Load (during Storage)100 m/s² at 11 ms
Maximum Acceleration Under Shock Load (during Transport)100 m/s² at 11 ms
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height6.300 cm
Package 1 Width27.000 cm
Package 1 Length28.000 cm
Package 1 Weight1.517 kg
Unit Type Of Package 2S06
Number Of Units In Package 240
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight70.000 kg
Logistical informations1
Country Of OriginDE
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents4

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support