Schneider ATS430D47S6 - ALTIVAR Soft Starter - ATS430 - 47A
Schneider

ATS430D47S6 - ALTIVAR Soft Starter - ATS430 - 47A

Schneider ATS430D47S6, ALTIVAR Soft Starter - ATS430 - 47A. Category: Altivar Soft Starter ATS430. Request a quote for price and lead time.

Key Specifications

Range Of Product
Altivar Soft Starter ATS430
Product Or Component Type
Soft starter
Product Destination
Asynchronous motors
Product Specific Application
Standard industrial machines

Product Description

This soft starter belongs to the Altivar Soft Starter ATS430 range which is intended to smoothly start and stop asynchronous motors supplied from 208 to 600V. With an operational rated current of 47A, it supplies motor from 11 to 30kW according to mains voltage. With an efficiency rating of 99.5%, torque control, high stress resistance, and complete monitoring, the ATS430 provides the essentials for effectiveness. Altivar Soft Starter ATS430 delivers best in class motor control with its torque control, the original by Schneider Electric. ATS430 provides complete system monitoring, including the motor, application, power and energy with an accuracy greater than 95%. The cybersecurity standards for ATS430 are met by incorporating best practices that help minimize downtime. Dimensions are 160mm (width), 194mm (depth), 273mm (height) and it weighs 3.4kg. ATS430 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified. Altivar Soft Starter ATS430 is designed for applications such as pumps, fans, compressors, conveyors, and mixers. It conforms to IEC/EN 60947-4-2 and has received CE, cULus, UKCA, RCM, KC, EAC and CCC certifications. Some accessories are available, including an IP65 or IP43 remote mounting kit for installing a plain text or graphic display terminal on the enclosure door. The packaging is made from recycled cardboard and incorporates less single-use plastic. The ATS430 soft starters shall be mounted vertically inside an enclosure. The Altivar Soft Starter ATS430 range offers torque control, reliable operation, and simplicity. It also integrates essential features for the future, including cybersecurity best practices and condition monitoring. ATS430 delivers the essentials for effectiveness while lowering the overall equipment costs.

Key Features

  • Reduce time (design to operation) and overall cost
  • Improved sustainability (enviromental performance, durability and efficiency)
  • Reduced operational expenditure (high durability)
  • Withstand high stress and avoid limiting event (increased reliability by design)
  • Meets cybersecurity standards (integrates best practice features)

Technical Specifications

Main16
Range Of ProductAltivar Soft Starter ATS430
Product Or Component TypeSoft starter
Product DestinationAsynchronous motors
Product Specific ApplicationStandard industrial machines
Device Short NameATS430
Network Number Of Phases3 phases
Utilisation CategoryAC-3A; AC-53A
Ue Power Supply Voltage208...600 V AC (- 15...10 %)
Power Supply Frequency50...60 Hz - 20...20 %
[Ie] Rated Operational CurrentNormal duty: 47 A in line (at <40 °C)
Service Factor At Ie100
Torque ControlTrue
IP Degree Of ProtectionIP20
Motor Power KW11 kW at 230 V in line normal duty; 22 kW at 400 V in line normal duty; 22 kW at 440 V in line normal duty; 30 kW at 500 V in line normal duty; 30 kW at 525 V in line normal duty
Motor Power Hp15 hp at 230 V normal duty; 30 hp at 460 V normal duty; 40 hp at 575 V normal duty
Communication Port ProtocolModbus serial
Complementary48
Device ConnectionIn line
Overload Current400 % Ie for 13 s
On-load Factor50 %
Operating Cycles/hour10 cyc/h
[Us] Control Circuit Voltage110...230 V AC 50...60 Hz - 15...10 %
Apparent Power70 VA
Integrated Motor Overload ProtectionTrue
Motor Thermal Protection ClassClass 10E
Protection TypePhase failure: mains; Thermal protection: mains; Thermal protection: starter; Current overload: motor; Motor underload: motor; Excessive acceleration time: motor; Motor phase loss detection: motor; Protection against line phase inversion: mains; External thermal protection: motor; Short-circuit between motor phase and earth: motor
Current Limiting %In (5 X Ie Maximum)150…700 %
Rated Current Pwr Loss Specification47 A
Power Loss Static Current Independent19 W
Power Loss Per Device Current Dependent12 W
Power Loss During Starting375 W during starting at 40 °C at 400% In
StandardsEN/IEC 60947-4-2; UL 60947-4-2; IEC 60664-1
Product CertificationscULus; CE; UKCA; CCC; RCM; EAC; KC
MarkingCULus; CE; UKCA; CCC; RCM; EAC; KC
[Uc] Control Circuit Voltage24 V DC
Discrete Input Number4
Discrete Input Type(STOP) digital input, 4.4 kOhm; (RUN) digital input, 4.4 kOhm; (DI3) digital input, 4.4 kOhm; (DI4) digital input, 4.4 kOhm
Input CompatibilitySTOP: digital input level 1 PLC conforming to EN/IEC 61131-2; RUN: digital input level 1 PLC conforming to EN/IEC 61131-2; DI3: digital input level 1 PLC conforming to EN/IEC 61131-2; DI4: digital input level 1 PLC conforming to EN/IEC 61131-2
Discrete Input LogicDigital input STOP at State 0: 0... 11 V, >= 5 mA; Digital input RUN at State 0: 0... 11 V, >= 5 mA; Digital input DI3 at State 0: 0... 11 V, >= 5 mA; Digital input DI4 at State 0: 0... 11 V, >= 5 mA
Relay Output Number2
Relay Output TypeRelay outputs R1A, R1C NO; Relay outputs R1B, R1C NC; Relay outputs R2A, R2C NO
Minimum Switching Current100 mA at 12 V DC for relay outputs
Maximum Switching CurrentRelay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1; Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
Analogue Input Number1
Analogue Input TypePTC1 : PTC temperature probe; PTC2 : PTC temperature probe
Analogue Output Number1
Analogue Output TypeCurrent output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm; Voltage output AQ1 : 0...10 V , impedance> 470 Ohm
Communication Port ProtocolModbus serial RJ45; Modbus serial open style (DO, D1, PE, COM)
Connector Type1 RJ45; Open style
Physical Interface2-wire RS 485 - connector(s): RJ45; 2-wire RS 485 - connector(s): open style (DO, D1, PE, COM)
Transmission FrameRTU : 1 RJ45; RTU : open style (DO, D1, PE, COM)
Transmission Rate4.8…38.4 kbps for Modbus serial RJ45; 0.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM)
Data Format8 bits, odd, even or no parity, 1 or 2 bits to stop for Modbus serial RJ45; 8 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM)
Number Of Addresses0…247 for Modbus serial
Method Of AccessSlave Modbus serial
Type Of PolarizationNo impedance for Modbus serial
Display Screen AvailableTrue
Operating PositionVertical +/- 10 degree
Height273 mm
Width130 mm
Depth194 mm
Net Weight3.40 kg
Internal BypassTrue
Function AvailableSingle direction; Pre-heating; Power monitoring; Condition monitoring; User management; Ports and services hardening; Security event logging; Cybersecure firmware update; Small motor test
Material DeclarationTrue
Environment19
Electromagnetic CompatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2; Electrostatic discharge level 3 conforming to IEC 61000-4-2; Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3; Immunity to electrical transients level 4 conforming to IEC 61000-4-4; Voltage/current impulse level 3 conforming to IEC 61000-4-5; Damped oscillating waves level 3 conforming to IE
Pollution DegreeLevel 3
[Uimp] Rated Impulse Withstand Voltage6 kV
[Ui] Rated Insulation Voltage600 V
Environmental Class (during Operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Ambient Air Temperature For Operation-25…40 °C (without derating); 40…60 °C (with current derating of 1 % per °C above 40 °C)
Ambient Air Temperature For Storage-40…70 °C
Ambient Air Transport Temperature-40…70 °C
Operating Altitude<= 2000 m without derating; > 2000...4800 m with current derating 1 % per 100 m above 2000 m
Relative Humidity5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum Deflection Under Vibratory Load (during Operation)1.5 mm at 2...13 Hz
Maximum Deflection Under Vibratory Load (during Storage)1.75 mm at 2...9 Hz
Maximum Deflection Under Vibratory Load (during Transport)1.75 mm at 2...9 Hz
Maximum Acceleration Under Vibrational Stress (during Operation)1 gn at 13…200 Hz
Maximum Acceleration Under Vibratory Load (during Storage)1 gn at 9…200 Hz; 1.5 gn at 200…500 Hz
Maximum Acceleration Under Vibratory Load (during Transport)1 gn at 9…200 Hz; 1.5 gn at 200…500 Hz
Maximum Acceleration Under Shock Impact (during Operation)15 gn at 11 ms
Maximum Acceleration Under Shock Load (during Storage)10 gn at 11 ms
Maximum Acceleration Under Shock Load (during Transport)10 gn at 11 ms
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height22.000 cm
Package 1 Width24.000 cm
Package 1 Length34.500 cm
Package 1 Weight4.518 kg
Unit Type Of Package 2S06
Number Of Units In Package 210
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight55.000 kg
Logistical informations1
Country Of OriginID
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents4

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support