Schneider ATV32HU22M2 - variable speed drive ATV32 - 2.2 kw - 200 V - 1 phase - with heat sink
Schneider

variable speed drive ATV32 - 2.2 kw - 200 V - 1 phase - with heat sink

Not for sale

Schneider ATV32HU22M2, variable speed drive ATV32 - 2.2 kw - 200 V - 1 phase - with heat sink. Category: Compact drives. Not for sale; no price or quote is offered for this product.

Key Specifications

Range Of Product
Altivar 32
Product Or Component Type
Variable speed drive
Product Destination
Synchronous motors; Asynchronous motors
Product Specific Application
Complex machines

Product Description

This Altivar 32 single phase variable speed drive has a rated power of 2.2kW, and a supply voltage of 200V to 240V AC. It is designed for applications such as small conveyors, hoists, bagging / labeling machines, mixers, kneaders, textile machines, pumps, compressors, fans, wood-working and metal processing machines. It has a 60mm-wide book form-factor, allowing for a flexible and easy installation on a mounting plate without any space between adjacent drives. It also offers a snap-lock seal, status and faults display, a jog dial navigation button and an integrated EMC filter. It offers high readability of key parameters thanks to a bright LED 4-digit display. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. • "Configurable with SoMove: one single software to use, less engineering time wasted"

Key Features

  • "Compatible with the multi-loader tool, for a faster setup without computer"
  • "Simple integration of the device in your automation system"
  • "Bright LED 4-digit display: high readability of key parameters"
  • "Integrated EMC filter"

Technical Specifications

Main14
Range Of ProductAltivar 32
Product Or Component TypeVariable speed drive
Product DestinationSynchronous motors; Asynchronous motors
Product Specific ApplicationComplex machines
Assembly StyleWith heat sink
Component NameATV32
EMC FilterClass C2 EMC filter integrated
Network Number Of Phases1 phase
[Us] Rated Supply Voltage200...240 V - 15...10 %
Supply Voltage Limits170…264 V
Supply Frequency50...60 Hz - 5...5 %
Network Frequency47.5...63 Hz
Motor Power KW2.2 kW at 200...240 V
Motor Power Hp3 hp at 200...240 V
Complementary55
Line Current20.1 A for 240 V 1 phase 2.2 kW / 3 hp; 23.9 A for 200 V 1 phase 2.2 kW / 3 hp
Apparent Power4.8 kVA at 240 V 1 phase 2.2 kW / 3 hp
Prospective Line Isc1 kA for 1 phase
Nominal Output Current11 A at 4 kHz 240 V 2.2 kW / 3 hp
Maximum Transient Current16.5 A for 60 s 2.2 kW / 3 hp
Output Frequency0.0005…0.599 kHz
Nominal Switching Frequency4 kHz
Switching Frequency2...16 kHz adjustable
Speed Range1…100 for asynchronous motor in open-loop mode
Speed Accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Torque Accuracy+/- 15 %
Transient Overtorque170…200 %
Braking Torque<= 170 % with braking resistor
Asynchronous Motor Control ProfileVoltage/frequency ratio, 5 points; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor - Energy Saving, NoLoad law; Flux vector control without sensor, standard; Voltage/frequency ratio, 2 points
Synchronous Motor Control ProfileVector control without sensor
Regulation LoopAdjustable PID regulator
Motor Slip CompensationAutomatic whatever the load; Not available in voltage/frequency ratio (2 or 5 points); Adjustable 0...300 %
Local Signalling1 LED red for drive voltage; 1 LED green for CANopen run; 1 LED red for CANopen error; 1 LED red for drive fault
Output Voltage<= power supply voltage
Noise Level43 dB conforming to 86/188/EEC
InsulationElectrical between power and control
Electrical ConnectionScrew terminal, clamping capacity: 4 mm², 10 AWG (power supply); Screw terminal, clamping capacity: 0.5...1.5 mm², 18 AWG...14 AWG (control); Removable screw terminals, clamping capacity: 1.5...2.5 mm², 14 AWG...12 AWG (motor/braking resistor)
Tightening Torque0.5 N.m, 4.4 lb/ft (control); 0.7 N.m, 7.1 lb/ft (motor/braking resistor); 0.6 N.m, 5.3 lb/ft (power supply)
SupplyInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Analogue Input Number3
Analogue Input TypeAI1 voltage: 0...10 V DC, impedance: 30000 Ohm, resolution 10 bits; AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30000 Ohm, resolution 10 bits; AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Sampling Duration2 ms (AI1, AI2, AI3) - analog input(s); 2 ms (AO1) - analog input(s)
Response TimeLI1...LI6 8 ms, tolerance +/- 0.7 ms for logic output(s); R1A, R1B, R1C 2 ms for relay output(s); R2A, R2C 2 ms for relay output(s)
Accuracy+/- 0.2 % (AI1, AI2, AI3) for a temperature of -10...60 °C; +/- 0.5 % (AI1, AI2, AI3) for a temperature of 25 °C; +/- 1 % (AO1) for a temperature of 25 °C; +/- 2 % (AO1) for a temperature of -10...60 °C
Linearity Error+/- 0.2...0.5 % of maximum value (AI1, AI2, AI3); +/- 0.3 % (AO1)
Analogue Output Number1
Analogue Output TypeAO1 software-configurable current 0...20 mA, impedance: 800 Ohm, resolution 10 bits; AO1 software-configurable voltage 0...10 V, impedance: 470 Ohm, resolution 10 bits
Discrete Output Number3
Discrete Output TypeConfigurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles; Logic: (LO)
Minimum Switching Current5 mA at 24 V DC for configurable relay logic
Maximum Switching CurrentR1: 3 A at 250 V AC resistive load, cos phi = 1; R1: 4 A at 30 V DC resistive load, cos phi = 1; R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4; R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4; R2: 5 A at 250 V AC resistive load, cos phi = 1; R2: 5 A at 30 V DC resistive load, cos phi = 1
Discrete Input Number7
Discrete Input TypeProgrammable (sink/source) (LI1...LI4)24...30 V DC, with level 1 PLC; Programmable as pulse input 20 kpps (LI5)24...30 V DC, with level 1 PLC; Switch-configurable PTC probe (LI6)24...30 V DC; Safe torque off (STO)24...30 V DC - 1500 Ohm
Discrete Input LogicNegative logic (sink) (LI1...LI6), > 19 V (state 0), < 13 V (state 1); Positive logic (source) (LI1...LI6), 11 V (state 1)
Acceleration And Deceleration RampsU; Ramp switching; Deceleration ramp automatic stop DC injection; S; CUS; Deceleration ramp adaptation; Linear
Braking To StandstillBy DC injection
Protection TypeInput phase breaks: drive; Overcurrent between output phases and earth: drive; Overheating protection: drive; Short-circuit between motor phases: drive; Thermal protection: drive
Communication Port ProtocolModbus; CANopen
Connector Type1 RJ45 (on front face) for Modbus/CANopen
Physical Interface2-wire RS 485 for Modbus
Transmission FrameRTU for Modbus
Type Of PolarizationNo impedance for Modbus
Number Of Addresses1…127 for CANopen; 1…247 for Modbus
Method Of AccessSlave CANopen
Electromagnetic Compatibility1.2/50 µs - 8/20 µs surge immunity test, level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test, level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test, level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test, level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test, level 3 conforming to
Width60 mm
Height325 mm
Depth245 mm
Net Weight2.9 kg
Option CardCommunication card for CANopen daisy chain; Communication card for CANopen open style; Communication card for DeviceNet; Communication card for EtherNet/IP; Communication card for Profibus DP V1
Environment12
StandardsEN/IEC 61800-3; EN 61800-3 environments 2 category C2; EN 55011 class A group 1; EN/IEC 61800-5-1; EN 61800-3 environments 1 category C2
Product CertificationsC-Tick; NOM 117; UL; CSA; GOST
MarkingCE
Pollution Degree2 conforming to EN/IEC 61800-5-1
IP Degree Of ProtectionIP20 conforming to EN/IEC 61800-5-1
Vibration Resistance1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm peak to peak (f = 3…13 Hz) conforming to EN/IEC 60068-2-6
Shock Resistance15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative Humidity5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3
Ambient Air Temperature For Operation-10…50 °C without derating; 50…60 °C with derating factor
Ambient Air Temperature For Storage-25…70 °C
Operating Altitude<= 1000 m without derating; 1000...2000 m with current derating 1 % per 100 m
Operating PositionVertical +/- 10 degree
Logistical informations1
Country Of OriginID
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support