Schneider ATV340D15N4 - ATV340 - 15 kW 3-phase
Schneider

ATV340D15N4 - ATV340 - 15 kW 3-phase

Schneider ATV340D15N4, ATV340 - 15 kW 3-phase. Category: Altivar Machine ATV340. Request a quote for price and lead time.

Key Specifications

Product Range
Altivar Machine ATV340
Product Or Component Type
Variable speed drive
Product Specific Application
Machine
Mounting Mode
Cabinet mount

Product Description

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 15kW / 20hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. it weighs 9.5kg and its dimensions are, 180mm wide, 385mm high, 249mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Technical Specifications

Product RangeAltivar Machine ATV340
Product Or Component TypeVariable speed drive
Product Specific ApplicationMachine
Mounting ModeCabinet mount
ModelStandard version
Communication Port ProtocolModbus serial
Option CardCommunication module, Profibus DP V1; Communication module, Profinet; Communication module, DeviceNet; Communication module, CANopen; Communication module, EtherCAT
Number Of Phases3 phases
Supply Frequency50...60 Hz +/- 5 %
[Us] Nominal Supply Voltage380...480 V - 15...10 %
Nominal Output Current32.0 A
Motor Power KW18.5 kW for normal duty; 15 kW for heavy duty
Motor Power Hp25 hp for normal duty; 20 hp for heavy duty
EMC FilterIntegrated class C3 EMC filter
IP Degree Of ProtectionIP20
Number Of Digital Inputs5
Digital Input TypePTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V); DI1...DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm; programmable
Preset Speed16 preset speeds
Number Of Digital Outputs2.0
Digital Output TypeProgrammable output DQ1, DQ2 30 V DC 100 mA
Number Of Analog Inputs2
Analog Input TypeAI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Number Of Analog Outputs1
Analog Output TypeSoftware-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
Number Of Relay Outputs2
Output Voltage<= power supply voltage
Relay Output TypeRelay outputs R1A; Relay outputs R1C electrical durability 100000 cycles; Relay outputs R2A; Relay outputs R2C electrical durability 100000 cycles
Maximum Switching CurrentRelay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2C on
Minimum Switching CurrentRelay output R1B: 5 mA at 24 V DC; Relay output R2C: 5 mA at 24 V DC
Physical Interface2-wire RS 485
Connector Type1 RJ45
Access MethodSlave Modbus RTU
Transmission Rate4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s
Transmission FrameRTU
Number Of Addresses1…247
Data Format8 bits, configurable odd, even or no parity
Polarization TypeNo impedance
4-quadrant Operation PossibleTrue
Asynchronous Motor Control ProfileVariable torque standard; Optimum torque mode; Constant torque standard
Synchronous Motor Control ProfileReluctance motor; Permanent magnet motor
Pollution Degree2 conforming to IEC 61800-5-1
Maximum Output Frequency0.599 kHz
Acceleration And Deceleration RampsLinear adjustable separately from 0.01...9999 s; S, U or customized
Motor Slip CompensationAutomatic whatever the load; Adjustable; Not available in permanent magnet motor law; Suppressible
Switching Frequency2...16 kHz adjustable; 7...16 kHz with derating factor
Nominal Switching Frequency4 kHz
Braking To StopBy DC injection
Brake Chopper IntegratedTrue
Line Current37.4 A at 380 V (normal duty); 30.2 A at 480 V (normal duty); 44.9 A at 380 V (heavy duty); 35.7 A at 480 V (heavy duty)
Maximum Input Current44.9 A
Maximum Output Voltage480 V
Apparent Power28.3 kVA at 480 V (normal duty); 29.7 kVA at 480 V (heavy duty)
Maximum Transient Current42.9 A for 60 s (normal duty); 48 A for 60 s (heavy duty); 52.7 A for 2 s (normal duty); 58 A for 2 s (heavy duty)
Electrical ConnectionScrew terminal, clamping capacity: 0.2...2.5 mm² for control; Screw terminal, clamping capacity: 6...25 mm² for line side; Screw terminal, clamping capacity: 6...25 mm² for DC bus; Screw terminal, clamping capacity: 4...25 mm² for motor
Prospective Line Isc22 kA
Base Load Current For High Overload32.0 A
Base Load Current For Low Overload39.0 A
Power Dissipation In WNatural convection: 18 W at 380 V 4 kHz (heavy duty); Forced convection: 346 W at 380 V 4 kHz (heavy duty); Natural convection: 21 W at 380 V 4 kHz (normal duty); Forced convection: 411 W at 380 V 4 kHz (normal duty)
Safety Function With Safe Direction (SDI)True
Safety Function With Safe Operating Stop (SOS)True
Safety Function With Safe Position (SP)False
Safety Function With Safe Programmable LogicFalse
Safety Function With Safe Speed Monitor (SSM)False
Safety Function With Safe Stop 1 (SS1)False
Sft Fct With Safe Stop 2 (SS2)True
Safety Function With Safe Torque Off (STO)False
With Closed DisplayTrue
Safety Function With Safe Brake Management (SBC/SBT)False
Safety Function With Safe Limited Position (SLP)False
Protection TypeThermal protection: motor; Safe torque off: motor; Motor phase loss: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent: drive; Output overcurrent between motor phase and earth: drive; Output overcurrent between motor phases: drive; Short-circuit between motor phase and earth: drive; Short-circuit between motor phases: drive; Motor phase loss: drive
Width180.0 mm
Height385.0 mm
Depth249.0 mm
Product Weight9.5 kg
Continuous Output Current39 A at 4 kHz for normal duty; 32 A at 4 kHz for heavy duty
Operating Altitude<= 3000 m with current derating above 1000m
Operating PositionVertical +/- 10 degree
Product CertificationsUL; CSA; TÜV; EAC; CTick
MarkingCE
StandardsIEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C
Mounting StyleWith heatsink
Electromagnetic CompatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated, radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conf
Environmental Class (during Operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum Acceleration Under Shock Impact (during Operation)70 m/s² at 22 ms
Maximum Acceleration Under Vibrational Stress (during Operation)5 m/s² at 9...200 Hz
Maximum Deflection Under Vibratory Load (during Operation)1.5 mm at 2...9 Hz
Permitted Relative Humidity (during Storage)Class 3K5 according to EN 60721-3
Cooling Air Volume128.0 m3/h
Type Of CoolingForced convection
Overvoltage CategoryClass III
Regulation LoopAdjustable PID regulator
Noise Level55.6 dB
Pollution Degree2
Battery Design Life-40…70 °C
Ambient Air Temperature For Operation-15…50 °C without (vertical position); 50…60 °C with derating factor (vertical position)
Storage Ambient Conditions-40…70 °C
InsulationBetween power and control terminals
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height34.000 cm
Package 1 Width30.500 cm
Package 1 Length56.000 cm
Package Weight (Lbs)11.140 kg
Unit Type Of Package 2P06
Number Of Units In Package 22
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight35.280 kg
Warranty (months)18

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support