Schneider ATV340D45N4E, ATV340 - 45 kW 3-phase ethernet. Category: Altivar Machine ATV340. Request a quote for price and lead time.

Key Specifications

Range Of Product
Altivar Machine ATV340
Product Or Component Type
Variable speed drive
Product Specific Application
Machine
Mounting Mode
Wall mount

Product Description

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 45kW / 60hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 56.4kg and its dimensions are, 271mm wide, 908mm high, 309mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM).

Key Features

  • "Powerful dynamism for superior machine performance"
  • "Unprecedented automation performance"
  • "Reduced machine design time"
  • "Simplified machine engineering"
  • "Seamless automation integration"

Technical Specifications

Main16
Range Of ProductAltivar Machine ATV340
Product Or Component TypeVariable speed drive
Product Specific ApplicationMachine
Mounting ModeWall mount
VariantStandard version
Communication Port ProtocolModbus TCP; Modbus serial; EtherNet/IP
Option CardCommunication module, PROFINET; Communication module, DeviceNet; Communication module, CANopen; Communication module, EtherCAT
Network Number Of Phases3 phases
Supply Frequency50...60 Hz +/- 5 %
[Us] Rated Supply Voltage380...480 V - 15...10 %
Nominal Output Current88.0 A
Motor Power KW55 kW for normal duty; 45 kW for heavy duty
Motor Power Hp75 hp for normal duty; 60 hp for heavy duty
EMC FilterClass C3 EMC filter integrated
IP Degree Of ProtectionIP20
Degree Of ProtectionUL type 1
Complementary60
Discrete Input Number8
Discrete Input TypePTI safe torque off: 0…30 kHz, 24 V DC (30 V); DI1...DI5 programmable as pulse input, 24 V DC (30 V), impedance: 3.5 kOhm; programmable
Number Of Preset Speeds16 preset speeds
Discrete Output Number1.0
Discrete Output TypeProgrammable output DQ1, DQ2 30 V DC 100 mA
Analogue Input Number3
Analogue Input TypeAI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue Output Number2
Analogue Output TypeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay Output Number3
Output Voltage<= power supply voltage
Relay Output TypeRelay outputs R1A; Relay outputs R1C electrical durability 100000 cycles; Relay outputs R2A; Relay outputs R2C electrical durability 100000 cycles
Maximum Switching CurrentRelay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC; Relay output R2C on resistive load, co
Minimum Switching CurrentRelay output R1B: 5 mA at 24 V DC; Relay output R2C: 5 mA at 24 V DC
Physical Interface2-wire RS 485
Connector Type3 RJ45
Method Of AccessSlave Modbus RTU; Slave Modbus TCP
Transmission Rate4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s
Transmission FrameRTU
Number Of Addresses1…247
Data Format8 bits, configurable odd, even or no parity
Type Of PolarizationNo impedance
4 Quadrant Operation PossibleTrue
Asynchronous Motor Control ProfileConstant torque standard; Optimized torque mode; Variable torque standard
Synchronous Motor Control ProfileReluctance motor; Permanent magnet motor
Pollution Degree2 conforming to IEC 61800-5-1
Maximum Output Frequency0.599 kHz
Acceleration And Deceleration RampsS, U or customized; Linear adjustable separately from 0.01...9999 s
Motor Slip CompensationNot available in permanent magnet motor law; Can be suppressed; Adjustable; Automatic whatever the load
Switching Frequency1...8 kHz adjustable; 2.5...8 kHz with derating factor
Nominal Switching Frequency2.5 kHz
Braking To StandstillBy DC injection
Brake Chopper IntegratedTrue
Line Current97.2 A at 380 V (normal duty); 84.2 A at 480 V (normal duty); 81.4 A at 380 V (heavy duty); 71.8 A at 480 V (heavy duty)
Maximum Input Current97.2 A
Maximum Output Voltage480 V
Apparent Power70 kVA at 480 V (normal duty); 59.7 kVA at 480 V (heavy duty)
Maximum Transient Current127.2 A during 60 s (normal duty); 132 A during 60 s (heavy duty); 127.2 A during 2 s (normal duty); 132 A during 2 s (heavy duty)
Electrical ConnectionScrew terminal, clamping capacity: 0.75...1.5 mm² for control; Screw terminal, clamping capacity: 70...120 mm² for line side; Screw terminal, clamping capacity: 70...120 mm² for DC bus; Screw terminal, clamping capacity: 70...120 mm² for motor
Prospective Line Isc50 kA
Base Load Current At High Overload88.0 A
Base Load Current At Low Overload106.0 A
Power Dissipation In WNatural convection: 105 W at 380 V, switching frequency 4 kHz (heavy duty); Forced convection: 943 W at 380 V, switching frequency 4 kHz (heavy duty); Natural convection: 115 W at 380 V, switching frequency 4 kHz (normal duty); Forced convection: 917 W at 380 V, switching frequency 4 kHz (normal duty)
With Safety Function Safely Limited Speed (SLS)True
With Safety Function Safe Brake Management (SBC/SBT)True
With Safety Function Safe Operating Stop (SOS)False
With Safety Function Safe Position (SP)False
With Safety Function Safe Programmable LogicFalse
With Safety Function Safe Speed Monitor (SSM)False
With Safety Function Safe Stop 1 (SS1)True
With Sft Fct Safe Stop 2 (SS2)False
With Safety Function Safe Torque Off (STO)True
With Safety Function Safely Limited Position (SLP)False
With Safety Function Safe Direction (SDI)False
Protection TypeThermal protection: motor; Safe torque off: motor; Motor phase loss: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent: drive; Output overcurrent between motor phase and earth: drive; Output overcurrent between motor phases: drive; Short-circuit between motor phase and earth: drive; Short-circuit between motor phases: drive; Motor phase loss: drive; DC Bus o
Width271.0 mm
Height908.0 mm
Depth309.0 mm
Net Weight56.4 kg
Continuous Output Current106 A at 4 kHz for normal duty; 88 A at 4 kHz for heavy duty
Environment23
Operating Altitude<= 4800 m with current derating above 1000m
Operating PositionVertical +/- 10 degree
Product CertificationsUL; CSA; TÜV; EAC; CTick
MarkingCE
StandardsIEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C; IEC 61000-3-12
Maximum THDI<48 % full load conforming to IEC 61000-3-12; <48 % 80 % load conforming to IEC 61000-3-12
Assembly StyleWith heat sink
Electromagnetic CompatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 6
Environmental Class (during Operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum Acceleration Under Shock Impact (during Operation)150 m/s² at 11 ms
Maximum Acceleration Under Vibrational Stress (during Operation)10 m/s² at 13...200 Hz
Maximum Deflection Under Vibratory Load (during Operation)1.5 mm at 2...13 Hz
Permitted Relative Humidity (during Operation)Class 3K5 according to EN 60721-3
Volume Of Cooling Air295.0 m3/h
Type Of CoolingForced convection
Overvoltage CategoryClass III
Regulation LoopAdjustable PID regulator
Noise Level62.4 dB
Pollution Degree2
Ambient Air Transport Temperature-40…70 °C
Ambient Air Temperature For Operation-15…50 °C without derating (vertical position); 50…60 °C with derating factor (vertical position)
Ambient Air Temperature For Storage-40…70 °C
IsolationBetween power and control terminals
Packing Units6
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height60.000 cm
Package 1 Width112.000 cm
Package 1 Length44.000 cm
Package 1 Weight57.500 kg
Logistical informations1
Country Of OriginCN
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.