C63R45E630 - NSX630 R ML5.3 45kA 690V 4P
Schneider C63R45E630, NSX630 R ML5.3 45kA 690V 4P. Category: ComPacT NSX, new generation. Request a quote for price and lead time.
- Reference:C63R45E630
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:6,848.00 EUR (Request a quote)
Key Specifications
- Range
- ComPacT
- Product Name
- ComPacT NSX
- Device Short Name
- NSX630R
- Product Or Component Type
- Circuit breaker
Product Description
This ComPacT NSX630R is a complete 4P 4d fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 200kA rms at 415VAC 50/60Hz and 45kA rms at 690VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds an electronic MicroLogic 5.3 E trip unit, with 630A rating. MicroLogic 5.3 E trip unit provides adjustable long time, short time and instantaneous protection. MicroLogic 5.3 E has an embedded display unit for fine settings adjustment and display of the energy (energy meter). This 4 poles version (185mm x 255mm x 110mm) comes with a variety of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX630R is part of Schneider Electric EcoStruxure Power architecture.
Key Features
- "Schneider Electric green signature style for the entire ComPacT range"
- "Estimated 40% reduction of wiring time for panel builders"
- "Experience easier installation thanks to a new ergonomic front-plate design"
- "Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating"
- "Ergonomic new toggle for easier breaker manual operation"
Technical Specifications
Main21
| Range | ComPacT |
|---|---|
| Product Name | ComPacT NSX |
| Device Short Name | NSX630R |
| Product Or Component Type | Circuit breaker |
| Device Application | Distribution |
| Poles Description | 4P |
| Protected Poles Description | 4D; 3D + OSN; 3D + N/2; 3D |
| Neutral Position | Left |
| [In] Rated Current | 630 A at 40 °C |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Suitability For Isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation Category | Category A |
| Breaking Capacity | 200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 80 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2; 45 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking Capacity Code | R 200 kA 415 V AC |
| Trip Unit Name | MicroLogic 5.3 E |
| Trip Unit Technology | Electronic |
| Trip Unit Protection Functions | LSI |
| Control Type | Toggle |
| Circuit Breaker Mounting Mode | Fixed |
Complementary36
| [Ui] Rated Insulation Voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| [Ics] Rated Service Breaking Capacity | 200 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2; 200 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2; 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2; 80 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2; 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2; 45 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical Durability | 15000 cycles |
| Electrical Durability | 8000 cycles at 440 V In/2; 4000 cycles at 440 V In; 6000 cycles at 690 V In/2; 2000 cycles at 690 V In |
| Power Dissipation Per Pole | 39.7 W |
| Mounting Support | Backplate |
| Mounting Position | Horizontal and vertical; Flat on the back |
| Upside Connection | Front |
| Downside Connection | Front |
| Connection Pitch | 45 mm |
| Protection Type | L : for overload protection (long time); S : for short time short-circuit protection; I : for instantaneous short-circuit protection |
| Trip Unit Rating | 630 A at 40 °C |
| Long-time Pick-up Adjustment Type Ir (thermal Protection) | Adjustable 9 settings |
| [Ir] Long-time Protection Pick-up Adjustment Range | 250...630 A |
| Long-time Protection Delay Adjustment Type Tr | Adjustable |
| [tr] Long-time Delay Adjustment Range | 15…400 s at 1.5 x Ir; 0.5…16 s at 6 x Ir; 0.35…11 s at 7.2 x Ir |
| Neutral Protection Setting | 0.5 x Ir (3D + N/2); 1 x Ir (4D); 1.6 x Ir (3D + OSN); No protection (3D) |
| Thermal Memory | 20 minutes before and after tripping |
| Short-time Protection Pick-up Adjustment Type Isd | Adjustable 9 settings |
| [Isd] Short-time Protection Pick-up Adjustment Range | 1.5...10 x Ir |
| Short-time Protection Delay Adjustment Type Tsd | Adjustable 5 settings |
| [tsd] Short-time Delay Adjustment Range | 0…0.4 s I²t=off; 0.1…0.4 s I²t=on |
| Instantaneous Protection Pick-up Adjustment Type Ii | Adjustable |
| [Ii] Instantaneous Protection Pick-up Adjustment Range | 1.5...11 x In |
| Earth-leakage Protection | Without |
| Zone Selective Interlocking ZSI | With |
| Number Of Slots | 6 slot(s) |
| Local Signalling | Flashing LED (green) for ready to operate; LED 105 % Ir (red) for overload; LED 90 % Ir (orange) for overload |
| Display Type | LCD display |
| Type Of Measurement | Energy meter |
| Communication Of Data | Maintenance indicators; Energy metering; Instantaneous and demand values; Time-stamped histories and event tables; Power quality; Protection and alarm settings; Demand current and power; Maximeters/minimeters |
| Width (W) | 185 mm |
| Height (H) | 255 mm |
| Depth (D) | 110 mm |
| Net Weight | 8.13 kg |
Environment10
| Standards | EN/IEC 60947-2 |
|---|---|
| Overvoltage Category | III |
| Electrical Shock Protection Class | Class II on front face |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| IP Degree Of Protection | IP40 conforming to IEC 60529 |
| IK Degree Of Protection | IK07 conforming to IEC 62262 |
| Ambient Air Temperature For Operation | -25…70 °C |
| Ambient Air Temperature For Storage | -40…85 °C |
| Relative Humidity | 0…95 % |
| Operating Altitude | 0...2000 m without derating; 2000 m...5000 m with derating |
Packing Units6
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 15.2 cm |
| Package 1 Width | 20.3 cm |
| Package 1 Length | 29.2 cm |
| Package 1 Weight | 7.643 kg |
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.