Key Specifications

Series
TeSys
Product Name
TeSys CAD
Product Or Component Type
Control relay
Device Short Name
CAD

Product Description

Schneider CAD50V7 (CAD50V7).

Technical Specifications

SeriesTeSys
Product NameTeSys CAD
Product Or Component TypeControl relay
Device Short NameCAD
Contactor ApplicationControl circuit
Utilization CategoryAC-14, AC-15, DC-13
Pole Contact Composition5 NO
Control Circuit TypeAC 50/60 Hz
Control Circuit Voltage400 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
[Ith] Conventional Free Air Thermal Current10 A at <= 60 °C
Irms Rated Making Capacity140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1
[Icw] Rated Short-time Withstand Current100 A 1 s, 120 A 500 ms, 140 A 100 ms
Associated Fuse Rating10 A gG conforming to IEC 60947-5-1
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-5-1, 600 V certifications UL, 600 V certifications CSA
Mounting SupportPlate, Rail
Connections - TerminalsScrew clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, Screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end, Screw clamp termina
Tightening Torque1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control Circuit Voltage Limits0.3...0.6 Uc drop-out, 0.8...1.1 Uc operational 50 Hz, 0.85...1.1 Uc operational 60 Hz
Operating Time12...22 ms coil energisation and NO closing, 4...12 ms coil de-energisation and NO opening
Mechanical Durability30 Mcycles
Maximum Operating Rate180 cyc/mn
Inrush Power In VA70 VA at 20 °C 50 Hz
Hold-in Power Consumption In VA8 VA at 20 °C 50 Hz
Minimum Switching Voltage17 V
Minimum Switching Current5 mA
Non-overlap Time1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact)
Insulation Resistance> 10 MOhm
Height77 mm
Width45 mm
Depth84 mm
Product Weight0.58 kg
StandardsBS 4794, EN 60947-5, IEC 60947-5-1, NF C 63-140, VDE 0660
Product CertificationsCSA, UL
IP Degree Of ProtectionIP2x front face conforming to VDE 0106
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-40...70 °C
Ambient Air Temperature For Storage-60...80 °C
Operating Altitude3000 m without derating
Mechanical RobustnessShocks control relay open 10 Gn for 11 ms IEC 60068-2-27, Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27, Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6, Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
Sustainable Offer StatusGreen Premium product
ROHSCompliant - since 0627 - Schneider Electric declaration of conformity
REACHReference not containing SVHC above the threshold
Product Environmental ProfileAvailable
End Of Life InstructionsAvailable