GV4PE02S - TeSys GV4 Motor Circuit Breaker Thermal Mag. 3P 2A 100kA
Schneider GV4PE02S, TeSys GV4 Motor Circuit Breaker Thermal Mag. 3P 2A 100kA. Category: TeSys Deca - frame 4. Request a quote for price and lead time.
- Reference:GV4PE02S
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:1,009.70 EUR (Request a quote)
Key Specifications
- Range
- TeSys Deca
- Range Of Product
- TeSys GV4
- Device Short Name
- GV4PE
- Product Name
- TeSys GV4
Product Description
TeSys GV motor circuit breaker, 3 poles (3P), 2A/690V, for protection of 3-phase motors 0.25-0.75kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 0.8-2A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).
Key Features
- "New modern look & feel of all machines"
- "Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)"
- "Easier to install and operate with multi-standard screws"
- "Safe and long-lasting power connection with EverLink terminals"
- "Digital customer experience for technical documents"
Technical Specifications
Main7
| Range | TeSys Deca |
|---|---|
| Range Of Product | TeSys GV4 |
| Device Short Name | GV4PE |
| Product Name | TeSys GV4 |
| Product Or Component Type | Motor circuit breaker |
| Device Application | Motor protection |
| Trip Unit Technology | Electronic; Thermal-magnetic |
Complementary27
| Poles Description | 3P |
|---|---|
| Utilisation Category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1 |
| Operating Position | Any position |
| Motor Power KW | 0.25 kW at 400...415 V AC 50/60 Hz; 0.37 kW at 400...415 V AC 50/60 Hz; 0.55 kW at 400...415 V AC 50/60 Hz; 0.75 kW at 400...415 V AC 50/60 Hz; 0.37 kW at 500 V AC 50/60 Hz; 0.55 kW at 500 V AC 50/60 Hz; 0.75 kW at 500 V AC 50/60 Hz; 1.1 kW at 500 V AC 50/60 Hz; 0.55 kW at 660...690 V AC 50/60 Hz; 0.75 kW at 660...690 V AC 50/60 Hz; 1.1 kW at 660...690 V AC 50/60 Hz; 1.5 kW at 660...690 V AC 50/60 |
| Breaking Capacity | 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2; 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947; 100 kA at 240 V AC 50/60 Hz conforming |
| Control Type | Toggle |
| [In] Rated Current | 2 A |
| Magnetic Tripping Current | 34 A |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] Rated Insulation Voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] Conventional Free Air Thermal Current | 115 A conforming to IEC 60947-4-1 |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV conforming to IEC 60947-2 |
| Power Dissipation Per Pole | 4.6 W |
| Mechanical Durability | 40000 cycles |
| Electrical Durability | 5000 cycles for AC-3 at 415 V opening; 5000 cycles for AC-3 at 415 V closing |
| Maximum Operating Rate | 25 cyc/h |
| Rated Duty | Continuous conforming to IEC 60947-4-1 |
| Connections - Terminals | EverLink BTR screw connectors (top): 1 cable(s) 1.5…70 mm² - solid; EverLink BTR screw connectors (top): 1 cable(s) 1.5…50 mm² - flexible; EverLink BTR screw connectors (bottom): 1 cable(s) 2.5…95 mm² - solid; EverLink BTR screw connectors (bottom): 1 cable(s) 2.5…70 mm² - flexible |
| Tightening Torque | 9 N.m for cable 16…95 mm²; 5 N.m for cable 1.5…10 mm² |
| Mechanical Robustness | Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6; Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6; Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| Phase Failure Sensitivity | Yes conforming to IEC 60947-4-1 |
| Height | 155 mm |
| Width | 81 mm |
| Depth | 116 mm |
| Net Weight | 1.45 kg |
| Colour | Grey (RAL 7016) |
| Suitability For Isolation | Yes conforming to IEC 60947-1 |
Environment10
| Standards | CSA C22.2 No 60947-4-1; UL 60947-4-1; EN/IEC 60947-4-1; EN/IEC 60947-2 |
|---|---|
| Product Certifications | IEC; UL; CSA; CCC; EAC; ATEX; EU-RO MR |
| Climatic Withstand | conforming to IACS E10 |
| IK Degree Of Protection | IK07 conforming to IEC 62262 |
| Pollution Degree | 3 |
| IP Degree Of Protection | IP40 conforming to IEC 60529 |
| Ambient Air Temperature For Storage | -50…85 °C |
| Fire Resistance | 960 °C conforming to IEC 60695-2-11 |
| Operating Altitude | 5000 m |
| Ambient Air Temperature For Operation | -25…70 °C |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 17.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 22.0 cm |
| Package 1 Weight | 1.71 kg |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 5 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 9.0 kg |
Logistical informations1
| Country Of Origin | PL |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.