Schneider
Switch: cam switch; Stabl.pos: 3; 12A; 2-0-1; for building in
Schneider K1D002ULH, Switch: cam switch; Stabl.pos: 3; 12A; 2-0-1; for building in. Category: Harmony K. In stock.
- Reference:K1D002ULH
- Manufacturer / Brand:Schneider
- Availability:In stock (2 pcs) ✅
- Price:45.90 EUR (Request a quote)
Key Specifications
- Range Of Product
- Harmony K
- Product Or Component Type
- Complete cam switch
- Component Name
- K1
- Product Mounting
- Front mounting
Product Description
This K1 2-pole changeover switch is ideal for direct control of simple machines, has a rated voltage of 690V AC and a rated current of 12A. It has a square shape and a metallic legend with black marking. It is IP65 and installs with screws. Its high IP allows for handling of panel operations in very dusty and wet environments, including outdoors.
Key Features
- "Robust proven design with a pre-assembled contacts body and a steel shaft"
- "12A / 690Vac contact rating to cater with most process control operation, without interposing relays"
- "IP65 to allow for installation in harsh environment or outdoor"
- "Wide availability throughout an extensive distribution network"
Technical Specifications
Main16
| Range Of Product | Harmony K |
|---|---|
| Product Or Component Type | Complete cam switch |
| Component Name | K1 |
| [Ith] Conventional Free Air Thermal Current | 12 A |
| Product Mounting | Front mounting |
| Fixing Mode | Multifixing |
| Cam Switch Head Type | With front plate 45 x 45 mm |
| Type Of Operator | Black handle, length = 35 mm |
| Rotary Handle Padlocking | Without |
| Presentation Of Legend | With metallic legend, 2 - 0 - 1 black marking |
| Cam Switch Function | Changeover switch |
| Return | Without |
| Off Position | With Off position |
| Poles Description | 2P |
| Switching Positions | Left: 0° - 315°; Right: 0° - 45° |
| IP Degree Of Protection | IP40 conforming to IEC 60529 |
Complementary18
| Switching Angle | 45 ° |
|---|---|
| [Ui] Rated Insulation Voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 |
| [Ithe] Conventional Enclosed Thermal Current | 10 A |
| Rated Operational Power In W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3; 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3; 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3; 2200 W AC-23A, 400 V |
| [Ie] Rated Operational Current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3; 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3; 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3; 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3; 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3; 5.6 A at 230 V A |
| Electrical Durability | 1000000 cycles AC-15; 1000000 cycles AC-21; 500000 cycles AC-23; 500000 cycles AC-3 |
| Maximum Operating Rate | 2.5 cyc/mn AC-21; 2.5 cyc/mn AC-23; 2.5 cyc/mn AC-3; 8.333 cyc/mn AC-15 |
| Short-circuit Current | 10000 A |
| Short-circuit Protection | 16 A cartridge fuse, type gG |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV in isolating function; 6 kV conforming to IEC 947-1 |
| Contact Operation | Slow-break |
| Positive Opening | With |
| Electrical Connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²; Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² |
| Mechanical Durability | 1000000 cycles |
| CAD Overall Width | 45 mm |
| CAD Overall Height | 45 mm |
| CAD Overall Depth | 87 mm |
| Net Weight | 0.14 kg |
Environment8
| Standards | IEC 60947-3 for power circuit; IEC 60947-5-1 for control circuit; CENELEC EN 50013 |
|---|---|
| Product Certifications | CSA 240 V 3 hp 3 phases 2 pole(s); UL 240 V 0.33 hp 1 phase 2 pole(s); CSA 240 V 1 hp 1 phase; UL 240 V 1 hp 3 phases |
| Protective Treatment | TC |
| Ambient Air Temperature For Operation | -25…55 °C |
| Ambient Air Temperature For Storage | -40…70 °C |
| Shock Resistance | 30 gn conforming to IEC 68-2-27 |
| Vibration Resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) |
| Electrical Shock Protection Class | Class II conforming to IEC 536; Class II |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 11.000 cm |
| Package 1 Weight | 155.000 g |
| Unit Type Of Package 2 | S01 |
| Number Of Units In Package 2 | 10 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 1.683 kg |
Logistical informations1
| Country Of Origin | CZ |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads