Schneider
Switch: voltmeter cam switch; Stabl.pos: 7; 12A; for building in
Schneider K1F027MLH, Switch: voltmeter cam switch; Stabl.pos: 7; 12A; for building in. Category: Harmony K. In stock.
- Reference:K1F027MLH
- Manufacturer / Brand:Schneider
- Availability:In stock (15 pcs) ✅
- Price:63.00 EUR (Request a quote)
Key Specifications
- Range Of Product
- Harmony K
- Product Or Component Type
- Complete cam switch
- Component Name
- K1
- Mounting Location
- Front
Product Description
This K1 voltmeter switch is ideal for switching between phase-phase and phase-neutral voltage measurements on a switchboard, has a rated voltage of 690V AC. It has a square shape and a metallic legend with black marking. It is IP65 and installs with screws. This voltmeter phase switch offers the maximum mechanical and electrical robustness of its class, for prolonged operation without maintenance. Its high IP allows for handling of panel operations in very dusty and wet environments, including outdoors.
Key Features
- "Modular design combining flexibility and adaptability"
- "Simplicity and speed of installation"
- "Wide range of solutions for all applications"
- "Modular Harmony design with plastic and metal heads"
- "Mechanical durability of 1 million cycles"
Technical Specifications
Main16
| Range Of Product | Harmony K |
|---|---|
| Product Or Component Type | Complete cam switch |
| Component Name | K1 |
| [Ith] Conventional Free Air Thermal Current | 12 A |
| Mounting Location | Front |
| Fixing Mode | Multifixing |
| Cam Switch Head Type | With front plate 45 x 45 mm |
| Type Of Operator | Black handle, length = 35 mm |
| Rotary Handle Padlocking | Without |
| Presentation Of Legend | With metallic legend, 0 - L1N - L2N - L3N - L1L2 - L2L3 - L3L1 black marking |
| Cam Switch Function | Voltmeter switch |
| Return | Without |
| Type Of Measurement | Between 3 phases and between each of the 3 phases and neutral |
| Off Position | With Off position |
| Switching Positions | Left: 0° - 315° - 270° - 225°; Right: 0° - 45° - 90° - 135° |
| IP Degree Of Protection | IP40 conforming to IEC 60529 |
Complementary18
| Switching Angle | 45 ° |
|---|---|
| [Ui] Rated Insulation Voltage | 690 V (pollution degree 3) conforming to IEC 60947-1 |
| [Ithe] Conventional Enclosed Thermal Current | 10 A |
| Rated Operational Power In W | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3; 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3; 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3; 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3; 2200 W AC-23A, 400 V |
| [Ie] Rated Operational Current AC | 1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3; 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3; 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3; 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3; 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3; 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3; 5.6 A at 230 V A |
| Electrical Durability | 1000000 cycles AC-15; 1000000 cycles AC-21; 500000 cycles AC-23; 500000 cycles AC-3 |
| Maximum Operating Rate | 2.5 cyc/mn AC-21; 2.5 cyc/mn AC-23; 2.5 cyc/mn AC-3; 8.333 cyc/mn AC-15 |
| Short-circuit Current | 10000 A |
| Short-circuit Protection | 16 A cartridge fuse, type gG |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV in isolating function; 6 kV conforming to IEC 947-1 |
| Contact Operation | Slow-break |
| Positive Opening | With |
| Electrical Connection | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²; Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² |
| Mechanical Durability | 1000000 cycles |
| CAD Overall Width | 45 mm |
| CAD Overall Height | 45 mm |
| CAD Overall Depth | 97 mm |
| Net Weight | 0.17 kg |
Environment8
| Standards | IEC 60947-3 for power circuit; IEC 60947-5-1 for control circuit; CENELEC EN 50013 |
|---|---|
| Product Certifications | CSA 240 V 1 hp 1 phase; CSA 240 V 3 hp 3 phases 2 -pole(s); UL 240 V 1 hp 3 phases; UL 240 V 0.33 hp 1 phase 2 -pole(s) |
| Protective Treatment | TC |
| Ambient Air Temperature For Operation | -25…55 °C |
| Ambient Air Temperature For Storage | -40…70 °C |
| Shock Resistance | 30 gn conforming to IEC 68-2-27 |
| Vibration Resistance | 5 gn conforming to IEC 68-2-6 (f = 10…150 Hz) |
| Overvoltage Category | Class II conforming to IEC 536; Class II conforming to NF C 20-030 |
Packing Units18
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 6.700 cm |
| Package 1 Width | 6.700 cm |
| Package 1 Length | 11.000 cm |
| Package 1 Weight | 179.000 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 40 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.563 kg |
| Unit Type Of Package 3 | P06 |
| Number Of Units In Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 71.804 kg |
Logistical informations1
| Country Of Origin | CZ |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.