Schneider LC1D12AM7 - TeSys Deca Contactor 3P 12A 220VAC Snap-in
Schneider

LC1D12AM7 - TeSys Deca Contactor 3P 12A 220VAC Snap-in

Schneider LC1D12AM7, TeSys Deca Contactor 3P 12A 220VAC Snap-in. Category: TeSys Deca Advanced. Request a quote for price and lead time.

Key Specifications

Range Of Product
TeSys Deca Advanced
Product Or Component Type
Contactor
Device Short Name
LC1D
Contactor Application
Motor control; Resistive load

Product Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V). It is equipped with snap-in terminals for tool-free flexible cable wiring and lifelong robust connection. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified). For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified, environmental compliant (RoHS/REACh).

Key Features

  • Snap-in terminals for tool-free flexible cable wiring and lifelong robust connection
  • Multiple accessories available for different motor stater applications to ensure efficient system installation
  • Improved fire resistance with IEC 60335-1(Clause 30.2) certificate by authorized agency
  • Anti-flammable refrigerants with IEC/EN certificate by authorized agency
  • Digital customer experience for technical documents

Technical Specifications

Main9
Range Of ProductTeSys Deca Advanced
Product Or Component TypeContactor
Device Short NameLC1D
Contactor ApplicationMotor control; Resistive load
Utilisation CategoryAC-1; AC-3; AC-3e; AC-4
Poles Description3P
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC
[Ie] Rated Operational Current12 A (at <60 °C) at <= 440 V AC-3 for power circuit; 12 A (at <60 °C) at <= 440 V AC-3e for power circuit; 25 A (at <60 °C) at <= 440 V AC-1 for power circuit
[Uc] Control Circuit Voltage220 V AC 50/60 Hz
Complementary35
Motor Power KW3 kW at 220...230 V AC 50/60 Hz (AC-3); 5.5 kW at 380...400 V AC 50/60 Hz (AC-3); 5.5 kW at 415...440 V AC 50/60 Hz (AC-3); 7.5 kW at 500 V AC 50/60 Hz (AC-3); 7.5 kW at 660...690 V AC 50/60 Hz (AC-3); 3.7 kW at 400 V AC 50/60 Hz (AC-4); 3 kW at 220...230 V AC 50/60 Hz (AC-3e); 5.5 kW at 380...400 V AC 50/60 Hz (AC-3e); 5.5 kW at 415...440 V AC 50/60 Hz (AC-3e); 7.5 kW at 500 V AC 50/60 Hz (AC-3e)
Compatibility CodeLC1D
Pole Contact Composition3 NO
Protective CoverWith
[Ith] Conventional Free Air Thermal Current25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit
Irms Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated Breaking Capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-time Withstand Current105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at <= 690 V coordination type 1 for power circuit; 25 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power Dissipation Per Pole0.36 W AC-3; 0.36 W AC-3e; 1.56 W AC-1
[Ui] Rated Insulation VoltagePower circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1
Overvoltage CategoryIII
Pollution Degree3
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical Durability15 Mcycles
Electrical Durability2 Mcycles 12 A AC-3 at Ue <= 440 V; 0.8 Mcycles 25 A AC-1 at Ue <= 440 V; 2 Mcycles 12 A AC-3e at Ue <= 440 V
Control Circuit TypeAC at 50/60 Hz standard
Coil TechnologyWithout built-in suppressor module
Control Circuit Voltage Limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush Power In VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in Power Consumption In VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat Dissipation2…3 W at 50/60 Hz
Operating Time12...22 ms closing; 4...19 ms opening
Maximum Operating Rate3600 cyc/h at 60 °C
Connections - TerminalsControl circuit: snap-in terminal 1 0.5…4 mm² - cable stiffness: flexible without cable end; Control circuit: snap-in terminal 2 0.5…4 mm² - cable stiffness: flexible without cable end; Control circuit: snap-in terminal 1 0.5…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: snap-in terminal 2 0.5…2.5 mm² - cable stiffness: flexible with cable end; Power circuit: snap-in termina
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling Circuit Frequency25...400 Hz
Minimum Switching Voltage17 V for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Insulation Resistance> 10 MOhm for signalling circuit
Non-overlap Time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting SupportPlate; Rail
Environment13
StandardsEN 60947-4-1; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product CertificationsCB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Protective TreatmentTH conforming to IEC 60068-2-30
Climatic Withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device-40…60 °C; 60…70 °C with derating
Operating Altitude0...3000 m
Fire Resistance850 °C conforming to IEC 60695-2-1
Mechanical RobustnessVibrations contactor open (2 Gn, 5...300 Hz); Vibrations contactor closed (4 Gn, 5...300 Hz); Shocks contactor closed (15 Gn for 11 ms); Shocks contactor open (10 Gn for 11 ms)
Height107 mm
Width45 mm
Depth86 mm
Net Weight387 g
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5 cm
Package 1 Width10.5 cm
Package 1 Length11.5 cm
Package 1 Weight407 g
Unit Type Of Package 2S02
Number Of Units In Package 215
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight6.42 kg
Unit Type Of Package 3P06
Number Of Units In Package 3240
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight111.22 kg
Contractual warranty1
Warranty (in Months)18