Schneider LC1D38ED - Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 48VDC; 38A
Schneider

Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 48VDC; 38A

Schneider LC1D38ED, Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 48VDC; 38A. Category: TeSys Deca Advanced. Request a quote for price and lead time.

Key Specifications

Range
TeSys; TeSys Deca
Range Of Product
TeSys Deca Advanced
Product Or Component Type
Contactor
Device Short Name
LC1D

Product Description

TeSys D contactor, 3 poles (3NO), for motor control applications up to 38A/690V AC-3/3e (18.5kW@400V). It provides a 48V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Key Features

  • New modern look & feel of all machines
  • Easier to install and operate with multi-standard screws
  • Improved fire resistancy with IEC 60335-1(Clause 30.2) certificate by authorized agency
  • Anti-flammable refrigerants with IEC/EN/UL 60335-2-40(Annex JJ) certificate by authorized agency
  • Digital customer experience for technical documents

Technical Specifications

Main10
RangeTeSys; TeSys Deca
Range Of ProductTeSys Deca Advanced
Product Or Component TypeContactor
Device Short NameLC1D
Contactor ApplicationResistive load; Motor control
Utilisation CategoryAC-3; AC-3e; AC-1; AC-4
Poles Description3P
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC
[Ie] Rated Operational Current50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 38 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit Voltage48 V DC
Complementary37
Motor Power KW9 kW at 220/230 V AC 50/60 Hz (AC-3); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3); 18.5 kW at 415/440 V AC 50/60 Hz (AC-3); 18.5 kW at 500 V AC 50/60 Hz (AC-3); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3); 9 kW at 220/230 V AC 50/60 Hz (AC-3e); 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 18.5 kW at 415/440 V AC 50/60 Hz (AC-3e); 18.5 kW at 500 V AC 50/60 Hz (AC-3e); 18.5 kW at 660/690 V AC 50/60 Hz (AC-3e);
Motor Power Hp10 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 5 hp at 240 V AC 50/60 Hz for 1 phase motors; 20 hp at 480 V AC 50/60 Hz for 3 phases motors; 25 hp at 600 V AC 50/60 Hz for 3 phases motors
Compatibility CodeLC1D
Pole Contact Composition3 NO
Protective CoverWith
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit; 50 A (at 60 °C) for power circuit
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 550 A at 440 V for power circuit conforming to IEC 60947
Rated Breaking Capacity550 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-time Withstand Current60 A 40 °C - 10 min for power circuit; 430 A 40 °C - 1 s for power circuit; 150 A 40 °C - 1 min for power circuit; 310 A 40 °C - 10 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at <= 690 V coordination type 1 for power circuit; 63 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance2 mOhm - Ith 50 A 50 Hz for power circuit
Power Dissipation Per Pole5 W AC-1; 3 W AC-3; 3 W AC-3e
[Ui] Rated Insulation VoltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage CategoryIII
Pollution Degree3
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical Durability30 Mcycles
Electrical Durability1.4 Mcycles 50 A AC-1 at Ue <= 440 V; 1.4 Mcycles 38 A AC-3 at Ue <= 440 V; 1.4 Mcycles 38 A AC-3e at Ue <= 440 V
Control Circuit TypeDC standard
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Control Circuit Voltage Limits0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Inrush Power In W5.4 W (at 20 °C)
Hold-in Power Consumption In W5.4 W at 20 °C
Operating Time20 ±20 % ms opening; 63 ±15 % ms closing
Time Constant28 ms
Maximum Operating Rate3600 cyc/h at 60 °C
Connections - TerminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: scr
Tightening TorqueControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2; Control circuit: 1.7 N.m - on screw clamp terminals - with screwdr
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling Circuit Frequency25...400 Hz
Minimum Switching Voltage17 V for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Insulation Resistance> 10 MOhm for signalling circuit
Non-overlap Time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting SupportPlate; Rail
Environment14
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product CertificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Protective TreatmentTH conforming to IEC 60068-2-30
Climatic Withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device-40…60 °C; 60…70 °C with derating
Operating Altitude0...3000 m
Fire Resistance850 °C conforming to IEC 60695-2-1
Flame RetardanceV1 conforming to UL 94
Mechanical RobustnessVibrations contactor open (2 Gn, 5...300 Hz); Vibrations contactor closed (4 Gn, 5...300 Hz); Shocks contactor closed (15 Gn for 11 ms); Shocks contactor open (8 Gn for 11 ms)
Height85 mm
Width45 mm
Depth101 mm
Net Weight0.54 kg
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5 cm
Package 1 Width9.3 cm
Package 1 Length11.2 cm
Package 1 Weight583 g
Unit Type Of Package 2S02
Number Of Units In Package 215
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.999 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support