Key Specifications

Range
TeSys; TeSys Deca
Range Of Product
TeSys Deca Advanced
Product Or Component Type
Contactor
Device Short Name
LC1D

Product Description

TeSys D contactor, 3 poles (3NO), for motor control applications up to 65A/440V AC-3/3e (30kW@400V). It provides a 380V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Key Features

  • "IEC 60335-1 (Clause 30.2) certificate by authorized agency"
  • "Designed to meet the requirements of industrial and HVAC applications"
  • "Easier to install and operate with multi-standard screws"
  • "IEC/EN/UL 60335-2-40 (Annex JJ) certificate by authorized agency"
  • "Digital customer experience for technical documents"

Technical Specifications

Main10
RangeTeSys; TeSys Deca
Range Of ProductTeSys Deca Advanced
Product Or Component TypeContactor
Device Short NameLC1D
Contactor ApplicationMotor control; Resistive load
Utilisation CategoryAC-3; AC-3e; AC-1; AC-4
Poles Description3P
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz; Power circuit: <= 300 V DC
[Ie] Rated Operational Current80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit; 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit; 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit Voltage380 V AC 50/60 Hz
Complementary37
Motor Power KW18.5 kW at 220/230 V AC 50/60 Hz (AC-3); 30 kW at 380/400 V AC 50/60 Hz (AC-3); 37 kW at 500 V AC 50/60 Hz (AC-3); 37 kW at 660/690 V AC 50/60 Hz (AC-3); 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 30 kW at 380/400 V AC 50/60 Hz (AC-3e); 37 kW at 500 V AC 50/60 Hz (AC-3e); 37 kW at 660/690 V AC 50/60 Hz (AC-3e); 11 kW at 400 V AC 50/60 Hz (AC-4)
Motor Power Hp40 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 5 hp at 115 V AC 50/60 Hz for 1 phase motors; 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility CodeLC1D
Pole Contact Composition3 NO
Protective CoverWith
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit; 80 A (at 60 °C) for power circuit
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1000 A at 440 V for power circuit conforming to IEC 60947
Rated Breaking Capacity1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-time Withstand Current640 A 40 °C - 10 s for power circuit; 900 A 40 °C - 1 s for power circuit; 110 A 40 °C - 10 min for power circuit; 260 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 125 A gG at <= 690 V coordination type 1 for power circuit; 125 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance1.5 mOhm - Ith 80 A 50 Hz for power circuit
Power Dissipation Per Pole9.6 W AC-1; 6.3 W AC-3; 6.3 W AC-3e
[Ui] Rated Insulation VoltagePower circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified; Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage CategoryIII
Pollution Degree3
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical Durability6 Mcycles
Electrical Durability1.4 Mcycles 80 A AC-1 at Ue <= 440 V; 1.45 Mcycles 65 A AC-3 at Ue <= 440 V; 1.45 Mcycles 65 A AC-3e at Ue <= 440 V
Control Circuit TypeAC at 50/60 Hz
Coil TechnologyWithout built-in suppressor module
Control Circuit Voltage Limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush Power In VA140 VA 60 Hz cos phi 0.75 (at 20 °C); 160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in Power Consumption In VA13 VA 60 Hz cos phi 0.3 (at 20 °C); 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat Dissipation4…5 W at 50/60 Hz
Operating Time4...19 ms opening; 12...26 ms closing
Maximum Operating Rate3600 cyc/h at 60 °C
Connections - TerminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end; Control circuit: scr
Tightening TorqueControl circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2; Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm; Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm; Control circui
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling Circuit Frequency25...400 Hz
Minimum Switching Voltage17 V for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Insulation Resistance> 10 MOhm for signalling circuit
Non-overlap Time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting SupportRail; Plate
Environment13
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product CertificationsCCC; UL; CB Scheme; CSA; CE; UKCA; Marine; EAC
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Protective TreatmentTH conforming to IEC 60068-2-30
Climatic Withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible Ambient Air Temperature Around The Device-40…60 °C; 60…70 °C with derating
Operating Altitude0...3000 m
Fire Resistance850 °C conforming to IEC 60695-2-1
Mechanical RobustnessVibrations contactor open (2 Gn, 5...300 Hz); Vibrations contactor closed (4 Gn, 5...300 Hz); Shocks contactor closed (15 Gn for 11 ms); Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width55 mm
Depth120 mm
Net Weight0.86 kg
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height6 cm
Package 1 Width14 cm
Package 1 Length15.5 cm
Package 1 Weight930 g
Unit Type Of Package 2S02
Number Of Units In Package 210
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.93 kg
Unit Type Of Package 3P06
Number Of Units In Package 3160
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight161.508 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1