Key Specifications

Range
TeSys
Range Of Product
TeSys Deca Advanced
Product Or Component Type
Contactor
Device Short Name
LC1D

Product Description

  • TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3/AC-3e (45kW@400V).
  • It provides a 48V DC coil, 1NO+1NC built-in auxiliary contacts, power connection by screw terminals and control by screw clamp terminals.
  • For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability.
  • Compact (85mm width), DIN-rail mounting or screw fixing.
  • Multi standards certified (IEC, CCC, EAC, Marine)

Key Features

  • "Long durability with high operating rate"
  • "Reliable performance under high environment"
  • "Green Premium product"
  • "Multi sdandards certified makes it possible to wide application"
  • "Easy installation and maintenance with compact design"

Technical Specifications

Main10
RangeTeSys
Range Of ProductTeSys Deca Advanced
Product Or Component TypeContactor
Device Short NameLC1D
Contactor ApplicationResistive load; Motor control
Utilisation CategoryAC-3; AC-3e; AC-1; AC-4
Poles Description3P
[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz
[Ie] Rated Operational Current95 A (at <60 °C) at <= 440 V AC-3 for power circuit; 125 A (at <60 °C) at <= 1000 V AC-1 for power circuit; 95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] Control Circuit Voltage48 V DC
Complementary37
Motor Power KW25 kW at 220/230 V AC 50/60 Hz (AC-3); 45 kW at 380/400 V AC 50/60 Hz (AC-3); 45 kW at 415/440 V AC 50/60 Hz (AC-3); 55 kW at 500 V AC 50/60 Hz (AC-3); 45 kW at 660/690 V AC 50/60 Hz (AC-3); 25 kW at 220/230 V AC 50/60 Hz (AC-3e); 45 kW at 380/400 V AC 50/60 Hz (AC-3e); 45 kW at 415/440 V AC 50/60 Hz (AC-3e); 55 kW at 500 V AC 50/60 Hz (AC-3e); 45 kW at 660/690 V AC 50/60 Hz (AC-3e); 15 kW at 400
Motor Power Hp7.5 hp at 120 V AC 60 Hz for 1 phase motors; 15 hp at 230/240 V AC 60 Hz for 1 phase motors; 30 hp at 200/208 V AC 60 Hz for 3 phases motors; 30 hp at 230/240 V AC 60 Hz for 3 phases motors; 60 hp at 460/480 V AC 60 Hz for 3 phases motors; 60 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility CodeLC1D
Pole Contact Composition3 NO
Protective CoverWith
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit; 125 A (at 60 °C) for power circuit
Irms Rated Making Capacity1100 A at 440 V AC for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated Breaking Capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-time Withstand Current1100 A 40 °C - 1 s for power circuit; 800 A 40 °C - 10 s for power circuit; 400 A 40 °C - 1 min for power circuit; 135 A 40 °C - 10 min for power circuit; 140 A - 100 ms for signalling circuit; 120 A - 500 ms for signalling circuit; 100 A - 1 s for signalling circuit
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 200 A gG at <= 690 V coordination type 1 for power circuit; 160 A gG at <= 690 V coordination type 2 for power circuit
Average Impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power Dissipation Per Pole12.5 W AC-1; 7.2 W AC-3; 7.2 W AC-3e
[Ui] Rated Insulation VoltagePower circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1
Overvoltage CategoryIII
Pollution Degree3
[Uimp] Rated Impulse Withstand Voltage8 kV conforming to IEC 60947
Safety Reliability LevelB10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical Durability10 Mcycles
Electrical Durability1.2 Mcycles 95 A AC-3; 1.3 Mcycles 125 A AC-1; 1.2 Mcycles 95 A AC-3e
Control Circuit TypeDC standard
Coil TechnologyWithout built-in suppressor module
Control Circuit Voltage Limits0.1...0.3 Uc (-40…70 °C):drop-out DC; 0.85...1.1 Uc (-40…55 °C):operational DC; 1...1.1 Uc (55…70 °C):operational DC
Inrush Power In W22 W (at 20 °C)
Hold-in Power Consumption In W22 W at 20 °C
Operating Time95...130 ms closing; 20...35 ms opening
Time Constant75 ms
Maximum Operating Rate3600 cyc/h at 60 °C
Connections - TerminalsControl circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end; Control circuit: s
Tightening TorqueControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling Circuit Frequency25...400 Hz
Minimum Switching Voltage17 V for signalling circuit
Minimum Switching Current5 mA for signalling circuit
Insulation Resistance> 10 MOhm for signalling circuit
Non-overlap Time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting SupportRail; Plate
Environment14
StandardsEN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; UL 60947-4-1; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; IEC 60335-1:Clause 30.2
Product CertificationsIECEE CB Scheme; CCC; EAC; LROS (Lloyds register of shipping); RINA; BV; DNV-GL
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Protective TreatmentTH conforming to IEC 60068-2-30
Climatic Withstandconforming to IACS E10 exposure to damp heat
Permissible Ambient Air Temperature Around The Device-40…60 °C; 60…70 °C with derating
Operating Altitude0...3000 m
Fire Resistance850 °C conforming to IEC 60695-2-1
Flame RetardanceV1 conforming to UL 94
Mechanical RobustnessVibrations contactor open (2 Gn, 5...300 Hz); Shocks contactor open (8 Gn for 11 ms); Vibrations contactor closed (3 Gn, 5...300 Hz); Shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width85 mm
Depth186 mm
Net Weight2.61 kg
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height21.000 cm
Package 1 Width10.000 cm
Package 1 Length14.000 cm
Package 1 Weight2.489 kg
Unit Type Of Package 2S02
Number Of Units In Package 22
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight5.238 kg
Unit Type Of Package 3P06
Number Of Units In Package 332
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight91.808 kg
Logistical informations1
Country Of OriginCZ
Contractual warranty1
Warranty (in Months)18