Schneider LC1F115E7 - TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 48 V AC
Schneider

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 48 V AC

Not for sale

Schneider LC1F115E7, TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 48 V AC. Category: TeSys F. Not for sale; no price or quote is offered for this product.

Key Specifications

Range
TeSys
Range Of Product
TeSys F
Product Or Component Type
Contactor
Device Short Name
LC1F

Product Description

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - Coil 48 V AC

Technical Specifications

Main10
RangeTeSys
Range Of ProductTeSys F
Product Or Component TypeContactor
Device Short NameLC1F
Contactor ApplicationResistive load; Motor control
Utilisation CategoryAC-3; AC-4; AC-1
Poles Description3P
[Ue] Rated Operational Voltage<= 690 V AC 50/60 Hz; <= 460 V DC
[Uc] Control Circuit Voltage48 V AC 40...400 Hz
[Ie] Rated Operational Current200 A (at <40 °C) at <= 440 V AC-1; 115 A (at <55 °C) at <= 440 V AC-3
Complementary25
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ith] Conventional Free Air Thermal Current200 A (at 40 °C)
Rated Breaking Capacity920 A conforming to IEC 60947-4-1
[Icw] Rated Short-time Withstand Current1100 A 40 °C - 10 s; 640 A 40 °C - 30 s; 520 A 40 °C - 1 min; 400 A 40 °C - 3 min; 320 A 40 °C - 10 min
Associated Fuse Rating125 A aM at <= 440 V; 200 A gG at <= 440 V
Average Impedance0.37 mOhm - Ith 200 A 50 Hz
[Ui] Rated Insulation Voltage1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C
Power Dissipation Per Pole15 W AC-1; 5 W AC-3
Overvoltage CategoryIII
Power Pole Contact Composition3 NO
Motor Power KW55 kW at 380...400 V AC 50/60 Hz (AC-3); 59 kW at 415 V AC 50/60 Hz (AC-3); 59 kW at 440 V AC 50/60 Hz (AC-3); 75 kW at 500 V AC 50/60 Hz (AC-3); 80 kW at 660...690 V AC 50/60 Hz (AC-3); 30 kW at 220...230 V AC 50/60 Hz (AC-3); 18.5 kW at 400 V AC 50/60 Hz (AC-4)
Control Circuit Voltage LimitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C); Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
Mechanical Durability10 Mcycles
Inrush Power In VA770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in Power Consumption In VA8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum Operating Rate2400 cyc/h 55 °C
Operating Time35 ms closing (at Uc); 130 ms opening (at Uc)
Connections - TerminalsPower circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm; Power circuit: lugs-ring terminals 1 cable(s) 95 mm²; Power circuit: connector 1 cable(s) 95 mm²; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible w
Tightening TorquePower circuit: 10 N.m; Control circuit: 1.2 N.m
Mounting SupportPlate
Heat Dissipation5.9…7.2 W
StandardsIEC 60947-4-1; JIS C8201-4-1; EN 60947-1; IEC 60947-1; EN 60947-4-1
Product CertificationsCB; RMRoS; RINA; BV; ABS; CCC; UL; LROS (Lloyds register of shipping); DNV
Compatibility CodeLC1F
Control Circuit TypeAC at 40...400 Hz
Environment10
IP Degree Of ProtectionIP2X front face with shrouds conforming to IEC 60529; IP2X front face with shrouds conforming to VDE 0106
Protective TreatmentTH
Ambient Air Temperature For Operation-40…60 °C
Ambient Air Temperature For Storage-60…80 °C
Permissible Ambient Air Temperature Around The Device60…70 °C at Uc
Height162 mm
Width163.3 mm
Depth171 mm
Operating Altitude3000 m without derating
Net Weight3.43 kg
Packing Units6
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height20.5 cm
Package 1 Width19.0 cm
Package 1 Length24.0 cm
Package 1 Weight4.182 kg
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support