Range
TeSys
Range Of Product
TeSys F
Product Or Component Type
Contactor
Device Short Name
LC1F

Product Description

  • High durability: 600 cycles/hour for operating rate
  • High reliability: environments tolerance up to 55°C
  • Easy installation and maintenance thanks to its drawer-mounted coil and a large choice of add-on blocks
  • Various fields of application with multiple standards certifications
  • Sustainability compliant

Technical Specifications

Main10
RangeTeSys
Range Of ProductTeSys F
Product Or Component TypeContactor
Device Short NameLC1F
Contactor ApplicationResistive load
Utilisation CategoryAC-1
Poles Description3P
[Ue] Rated Operational Voltage<= 460 V DC; <= 690 V AC 50/60 Hz
[Uc] Control Circuit Voltage110 V AC 40...400 Hz
[Ie] Rated Operational Current1260 A (at <40 °C) AC-1
Complementary23
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ith] Conventional Free Air Thermal Current1260 A (at 40 °C)
Rated Breaking Capacity1890 A conforming to IEC 60947-4-1
[Icw] Rated Short-time Withstand Current3000 A 40 °C - 3 min; 8000 A 40 °C - 10 s; 5200 A 40 °C - 30 s; 4000 A 40 °C - 1 min; 2000 A 40 °C - 10 min
Associated Fuse Rating1000 A gG at <= 440 V
Average Impedance0.12 mOhm - Ith 1260 A 50 Hz
[Ui] Rated Insulation Voltage1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C
Power Dissipation Per Pole120 W AC-1
Overvoltage CategoryIII
Power Pole Contact Composition3 NO
Control Circuit Voltage LimitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C); Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C)
Inrush Power In VA1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in Power Consumption In VA22 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum Operating Rate1200 cyc/h 55 °C
Operating Time40...80 ms closing; 100...200 ms opening
Connections - TerminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid w
Tightening TorqueControl circuit: 1.2 N.m; Power circuit: 58 N.m
Mounting SupportPlate
Heat Dissipation20 W
StandardsEN 60947-1; IEC 60947-1; IEC 60947-4-1; JIS C8201-4-1; EN 60947-4-1
Product CertificationsCB; UL; CSA; CQC; CE; UKCA; CCC
Compatibility CodeLC1F
Control Circuit TypeAC at 40...400 Hz
Environment9
Protective TreatmentTH
Ambient Air Temperature For Operation-5…40 °C
Ambient Air Temperature For Storage-60…80 °C
Permissible Ambient Air Temperature Around The Device-40…60 °C
Height338 mm
Width309 mm
Depth255 mm
Operating Altitude3000 m without derating
Net Weight19 kg
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height29.500 cm
Package 1 Width37.000 cm
Package 1 Length46.000 cm
Package 1 Weight21.700 kg
Unit Type Of Package 2P06
Number Of Units In Package 24
Package 2 Height75.000 cm
Package 2 Width80.000 cm
Package 2 Length64.000 cm
Package 2 Weight96.800 kg
Logistical informations1
Country Of OriginCZ
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support