Schneider
LC1F1250F7 - TeSys F Contactor 3P 1260A AC1 110VAC
Schneider LC1F1250F7, TeSys F Contactor 3P 1260A AC1 110VAC. Category: TeSys F. Request a quote for price and lead time.
- Reference:LC1F1250F7
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:5,335.05 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Range Of Product
- TeSys F
- Product Or Component Type
- Contactor
- Device Short Name
- LC1F
Product Description
- High durability: 600 cycles/hour for operating rate
- High reliability: environments tolerance up to 55°C
- Easy installation and maintenance thanks to its drawer-mounted coil and a large choice of add-on blocks
- Various fields of application with multiple standards certifications
- Sustainability compliant
Technical Specifications
Main10
| Range | TeSys |
|---|---|
| Range Of Product | TeSys F |
| Product Or Component Type | Contactor |
| Device Short Name | LC1F |
| Contactor Application | Resistive load |
| Utilisation Category | AC-1 |
| Poles Description | 3P |
| [Ue] Rated Operational Voltage | <= 460 V DC; <= 690 V AC 50/60 Hz |
| [Uc] Control Circuit Voltage | 110 V AC 40...400 Hz |
| [Ie] Rated Operational Current | 1260 A (at <40 °C) AC-1 |
Complementary23
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
|---|---|
| [Ith] Conventional Free Air Thermal Current | 1260 A (at 40 °C) |
| Rated Breaking Capacity | 1890 A conforming to IEC 60947-4-1 |
| [Icw] Rated Short-time Withstand Current | 3000 A 40 °C - 3 min; 8000 A 40 °C - 10 s; 5200 A 40 °C - 30 s; 4000 A 40 °C - 1 min; 2000 A 40 °C - 10 min |
| Associated Fuse Rating | 1000 A gG at <= 440 V |
| Average Impedance | 0.12 mOhm - Ith 1260 A 50 Hz |
| [Ui] Rated Insulation Voltage | 1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C |
| Power Dissipation Per Pole | 120 W AC-1 |
| Overvoltage Category | III |
| Power Pole Contact Composition | 3 NO |
| Control Circuit Voltage Limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C); Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C) |
| Inrush Power In VA | 1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Hold-in Power Consumption In VA | 22 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Maximum Operating Rate | 1200 cyc/h 55 °C |
| Operating Time | 40...80 ms closing; 100...200 ms opening |
| Connections - Terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid w |
| Tightening Torque | Control circuit: 1.2 N.m; Power circuit: 58 N.m |
| Mounting Support | Plate |
| Heat Dissipation | 20 W |
| Standards | EN 60947-1; IEC 60947-1; IEC 60947-4-1; JIS C8201-4-1; EN 60947-4-1 |
| Product Certifications | CB; UL; CSA; CQC; CE; UKCA; CCC |
| Compatibility Code | LC1F |
| Control Circuit Type | AC at 40...400 Hz |
Environment9
| Protective Treatment | TH |
|---|---|
| Ambient Air Temperature For Operation | -5…40 °C |
| Ambient Air Temperature For Storage | -60…80 °C |
| Permissible Ambient Air Temperature Around The Device | -40…60 °C |
| Height | 338 mm |
| Width | 309 mm |
| Depth | 255 mm |
| Operating Altitude | 3000 m without derating |
| Net Weight | 19 kg |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 29.500 cm |
| Package 1 Width | 37.000 cm |
| Package 1 Length | 46.000 cm |
| Package 1 Weight | 21.700 kg |
| Unit Type Of Package 2 | P06 |
| Number Of Units In Package 2 | 4 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 80.000 cm |
| Package 2 Length | 64.000 cm |
| Package 2 Weight | 96.800 kg |
Logistical informations1
| Country Of Origin | CZ |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.