| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
|---|
| [Ith] Conventional Free Air Thermal Current | 700 A (at 40 °C) |
|---|
| Rated Breaking Capacity | 4000 A conforming to IEC 60947-4-1 |
|---|
| [Icw] Rated Short-time Withstand Current | 4200 A 40 °C - 10 s; 3200 A 40 °C - 30 s; 2400 A 40 °C - 1 min; 1500 A 40 °C - 3 min; 1200 A 40 °C - 10 min |
|---|
| Associated Fuse Rating | 500 A aM at <= 440 V; 800 A gG at <= 440 V |
|---|
| Average Impedance | 0.18 mOhm - Ith 700 A 50 Hz |
|---|
| [Ui] Rated Insulation Voltage | 1000 V conforming to IEC 60947-4-1; 1500 V conforming to VDE 0110 group C |
|---|
| Power Dissipation Per Pole | 88 W AC-1; 45 W AC-3 |
|---|
| Overvoltage Category | III |
|---|
| Power Pole Contact Composition | 3 NO |
|---|
| Motor Power KW | 250 kW at 380...400 V AC 50/60 Hz (AC-3); 280 kW at 415 V AC 50/60 Hz (AC-3); 295 kW at 440 V AC 50/60 Hz (AC-3); 355 kW at 500 V AC 50/60 Hz (AC-3); 335 kW at 660...690 V AC 50/60 Hz (AC-3); 335 kW at 1000 V AC 50/60 Hz (AC-3); 147 kW at 220...230 V AC 50/60 Hz (AC-3); 80 kW at 400 V AC 50/60 Hz (AC-4) |
|---|
| Control Circuit Voltage Limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C); Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) |
|---|
| Mechanical Durability | 10 Mcycles |
|---|
| Inrush Power In VA | 1100 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
|---|
| Hold-in Power Consumption In VA | 18 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
|---|
| Maximum Operating Rate | 2400 cyc/h 55 °C |
|---|
| Operating Time | 40...65 ms closing; 100...170 ms opening |
|---|
| Connections - Terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid w |
|---|
| Tightening Torque | Control circuit: 1.2 N.m; Power circuit: 35 N.m |
|---|
| Mounting Support | Plate |
|---|
| Heat Dissipation | 18 W |
|---|
| Motor Power Range | 250…500 kW at 380…440 V 3 phases; 110…220 kW at 380…440 V 3 phases; 110…220 kW at 200…240 V 3 phases; 250…500 kW at 480…500 V 3 phases |
|---|
| Motor Starter Type | Direct on-line contactor |
|---|
| Contactor Coil Voltage | 48 V AC standard |
|---|
| Standards | EN 60947-4-1; EN 60947-1; IEC 60947-1; IEC 60947-4-1; JIS C8201-4-1 |
|---|
| Product Certifications | CSA; RINA; RMRoS; DNV; CB; BV; ABS; UL; LROS (Lloyds register of shipping); UKCA |
|---|
| Compatibility Code | LC1F |
|---|
| Control Circuit Type | AC at 40...400 Hz |
|---|