Schneider
LC1G150LSEA - TeSys Giga Contactor TeSysG150 3P Advanced 200-500V ACDC
Schneider LC1G150LSEA, TeSys Giga Contactor TeSysG150 3P Advanced 200-500V ACDC. Category: TeSys Giga contactors. Request a quote for price and lead time.
- Reference:LC1G150LSEA
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:723.60 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Range Of Product
- TeSys Giga
- Product Or Component Type
- Contactor
- Device Short Name
- LC1G
Product Description
- TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 150A 90kW@440V.
- equipped with 200-500V AC/DC wide band low consumption electronic coil,
- PLC output control and embedded with highly reliable 1NO+1NC auxiliary contact block (17V 1mA).
- Designed for demanding applications with maximum operating rates up to 500 cycles per hour and environments up to 60°C.
- It’s built with high reliability delivering mechanical durability up to 8 million cycles.
- Contact Wear Diagnosis (CWD) is a standard function,
- It continuously monitors and provide feedback through healthy and alarm conditions by an LED indicator.
- Remote signaling of wear diagnosis is enabled by an optional Remote Wear Diagnosis (RWD) module.
- It is possible to replace switching module (main contacts),
- control module enhancing contactor life and maintenance possible without removing main power cables/busbars,
- thanks to cable-memory connection blocks.
- Front accessible main power connections are with bolted connection and control connections by push-in terminals and easy and quick assembly.
- It provides IP2x protection from front face with optional terminal shrouds conforming to IEC 60529 and VDE 0106.
- It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, with no derating up to 3000m altitude.
- Contactor can be installed in three quadrants of vertical plane, and OLR could be directly mounted below contactor.
- The dimensions are 255mm x 108mm x 193mm (H x W x D), compact size enables panel space savings.
- Multi standards certified (CB, CCC, cULcs, CE, UKCA marking).
- Unique QR code provides quick access to complete product data.
Key Features
- "Designed to meet needs of demanding applications built-in with advanced features and functionalities"
- "Fewer references covering wider applications means simpler to select and less inventory to carry"
- "Coil designed for less energy consumption and wider voltage band-width"
- "Modular design and compact size for easy maintenance, short down times and less installation space consumption"
- "Advanced Local & Remote Contact Wear Diagnostic feature for predictive maintenance"
Technical Specifications
Main11
| Range | TeSys |
|---|---|
| Range Of Product | TeSys Giga |
| Product Or Component Type | Contactor |
| Device Short Name | LC1G |
| Contactor Application | Power switching; Motor control |
| Utilisation Category | AC-1; AC-3; AC-3e; AC-4; AC-5a; AC-5b; AC-6a; AC-6b; AC-8b; AC-8a; DC-1; DC-3; DC-5 |
| Poles Description | 3P |
| [Ue] Rated Operational Voltage | <= 1000 V AC 50/60 Hz; <= 460 V DC |
| [Ie] Rated Operational Current | 275 A (at <40 °C) at <= 1000 V AC-1; 150 A (at <60 °C) at <= 440 V AC-3 |
| [Uc] Control Circuit Voltage | 200...500 V AC 50/60 Hz; 200...500 V DC |
| Control Circuit Voltage Limits | Operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C); Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
Complementary32
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
|---|---|
| Overvoltage Category | III |
| Rated Breaking Capacity | 1280 A at 440 V |
| [Icw] Rated Short-time Withstand Current | 1.2 kA - 10 s; 0.7 kA - 30 s; 0.6 kA - 1 min; 0.45 kA - 3 min; 0.35 kA - 10 min |
| Associated Fuse Rating | 160 A aM at <= 440 V for motor; 160 A aM at <= 690 V for motor; 315 A gG at <= 690 V; 300 A UL Type J at <= 600 V |
| Average Impedance | 0.00018 Ohm |
| [Ui] Rated Insulation Voltage | 1000 V |
| Power Dissipation Per Pole | 10 W AC-1 - Ith 275 A; 5 W AC-3 - Ith 150 A |
| Compatibility Code | LC1G |
| Pole Contact Composition | 3 NO |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Motor Power KW | 37 kW at 230 V AC 50/60 Hz (AC-3e); 75 kW at 400 V AC 50/60 Hz (AC-3e); 75 kW at 415 V AC 50/60 Hz (AC-3e); 90 kW at 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 90 kW at 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e); 37 kW at 230 V AC 50/60 Hz (AC-3); 75 kW at 400 V AC 50/60 Hz (AC-3); 75 kW at 415 V AC 50/60 Hz (AC-3); 90 kW at 440 V AC 50/60 Hz (AC-3); 90 kW a |
| Motor Power Hp | 40 hp at 200/208 V 60 Hz; 50 hp at 230/240 V 60 Hz; 100 hp at 460/480 V 60 Hz; 125 hp at 575/600 V 60 Hz |
| Coil Technology | Built-in bidirectional peak limiting |
| Safety Reliability Level | B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical Durability | 8 Mcycles |
| Inrush Power In VA (50/60 Hz, AC) | 295 VA |
| Inrush Power In W (DC) | 215 W |
| Hold-in Power Consumption In VA (50/60 Hz, AC) | 13.0 VA |
| Hold-in Power Consumption In W (DC) | 8.0 W |
| Operating Time | 40...70 ms closing; 15...50 ms opening |
| Maximum Operating Rate | 600 cyc/h AC-3; 600 cyc/h AC-3e; 300 cyc/h AC-1; 150 cyc/h AC-4 |
| Connections - Terminals | Power circuit: bar 2 - busbar cross section: 25 x 6 mm; Power circuit: lugs-ring terminals 1 185 mm²; Power circuit: bolted connection; Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end; Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end; Control circuit: push-in 2 0.5…1.0 mm² with cable end; Control circuit: push-in 0.75…2.5 |
| Connection Pitch | 35 mm |
| Mounting Support | Plate |
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1; JIS C8201-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-1; UL 60335-2-40:Annex JJ |
| Product Certifications | CB Scheme; CCC; cULus; EAC; CE; UKCA; EU-RO-MR by DNV-GL |
| Tightening Torque | 18 N.m |
| Height | 255 mm |
| Width | 108 mm |
| Depth | 193 mm |
| Net Weight | 4.1 kg |
Environment7
| IP Degree Of Protection | IP2X front face with shrouds conforming to IEC 60529; IP2X front face with shrouds conforming to VDE 0106 |
|---|---|
| Ambient Air Temperature For Operation | -25…60 °C |
| Ambient Air Temperature For Storage | -60…80 °C |
| Mechanical Robustness | Vibrations 5…300 Hz 2 gn contactor open; Vibrations 5…300 Hz 4 gn contactor closed; Shocks 10 gn 11 ms contactor open; Shocks 15 gn 11 ms contactor closed |
| Colour | Dark grey |
| Protective Treatment | TH |
| Permissible Ambient Air Temperature Around The Device | -40…70 °C at Uc |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 26 cm |
| Package 1 Width | 17.5 cm |
| Package 1 Length | 32 cm |
| Package 1 Weight | 5.072 kg |
| Unit Type Of Package 2 | P06 |
| Number Of Units In Package 2 | 8 |
| Package 2 Height | 75 cm |
| Package 2 Width | 60 cm |
| Package 2 Length | 80 cm |
| Package 2 Weight | 49.076 kg |
Logistical informations1
| Country Of Origin | CZ |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads