
Schneider
Thermal relay; NO + NC; screw terminals; 5.5÷8A; -20÷55°C
Schneider LR2K0314, Thermal relay; NO + NC; screw terminals; 5.5÷8A; -20÷55°C. Category: TeSys LR2 k. In stock.
- Reference:LR2K0314
- Manufacturer / Brand:Schneider
- Availability:In stock (13 pcs) ✅
- Price:59.50 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Product Name
- TeSys LRK
- Product Or Component Type
- Differential thermal overload relay
- Device Short Name
- LR2K
Product Description
- TeSys LRK thermal overload relay, 8A/690V, thermal setting range 5.5-8A, tripping class 10A, for protection of 3-phase motors 3kW@400V.
- Differential device with phase failure and load unbalance detection.
- It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling.
- Settings are protected by a transparent cover lockable by sealing.
- Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K09-K16.
- Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately).
- Multi standards certified (IEC, UL, CSA, CCC, EAC),
Key Features
- "Tesys K thermal overload relays are designed to protect a.c. circuits and motors against overloads."
- "Simple to select and install at optimized budget"
- "The range delivers strong performance for its compact size and promises seamless integration in all applications."
- "Widely used for industry, infrastructure and building applications."
- "Designed for simple control systems"
Technical Specifications
Main10
| Range | TeSys |
|---|---|
| Product Name | TeSys LRK |
| Product Or Component Type | Differential thermal overload relay |
| Device Short Name | LR2K |
| Relay Application | Motor protection |
| Product Compatibility | LC7K; LC1K; LP4K; LP1K |
| Network Type | DC; AC |
| Thermal Overload Class | Class 10A conforming to IEC 60947-4-1 |
| Thermal Protection Adjustment Range | 5.5…8 A |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to BS 4941; Power circuit: 690 V conforming to IEC 60947; Power circuit: 750 V conforming to VDE 0110 group C; Power circuit: 600 V conforming to CSA C22.2 No 14 |
Complementary17
| Network Frequency | <= 400 Hz |
|---|---|
| Mounting Support | Under contactor; Plate, with specific accessories; Rail, with specific accessories |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Ith] Conventional Free Air Thermal Current | 6 A for signalling circuit |
| [Ue] Rated Operational Voltage | <= 690 V for power circuit; 690 V AC AC-15 for signalling circuit; 250 V DC DC-13 for signalling circuit |
| Associated Fuse Rating | 6 A gG for signalling circuit conforming to VDE 0660; 6 A gG for signalling circuit conforming to IEC 60947 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV |
| Power Dissipation Per Pole | 2 W |
| Phase Failure Sensitivity | Yes conforming to IEC 60947-4-1 |
| Local Signalling | Trip indicator (yellow) |
| Control Type | Red push-button: trip test function; Blue push-button: stop and manual reset; selector switch: manual or automatic reset |
| Connections - Terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
| Tightening Torque | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.3 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 65 mm |
| Net Weight | 0.145 kg |
Environment10
| Standards | VDE 0660; NF C 63-650; IEC 60947; BS 4941 |
|---|---|
| Product Certifications | UL; CSA; UKCA |
| Protective Treatment | TC conforming to IEC 60068; TC conforming to DIN 50016 |
| IP Degree Of Protection | IP2X conforming to IEC 60529 |
| Ambient Air Temperature For Operation | -20…55 °C without derating conforming to IEC 60947; -30…60 °C with derating conforming to IEC 60947 |
| Ambient Air Temperature For Storage | -40…70 °C |
| Operating Altitude | 2000 m without derating |
| Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Mechanical Robustness | Shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 7.100 cm |
| Package 1 Length | 8.200 cm |
| Package 1 Weight | 159.000 g |
| Unit Type Of Package 2 | S02 |
| Number Of Units In Package 2 | 41 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.756 kg |
Logistical informations1
| Country Of Origin | CZ |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.