Schneider LRD3365 - Thermal relay; screw terminals; 80÷104A; TeSys D
Schneider

Thermal relay; screw terminals; 80÷104A; TeSys D

Schneider LRD3365, Thermal relay; screw terminals; 80÷104A; TeSys D. Category: TeSys Deca overload relays. In stock.

Key Specifications

Range
TeSys
Product Name
TeSys LRD; TeSys Deca
Product Or Component Type
Differential thermal overload relay
Device Short Name
LRD

Product Description

  • TeSys LRD thermal overload relay, 104A/1000V, thermal setting range 80-104A, tripping class 10A, for protection of 3-phase motors 45kW@400V.
  • Differential device with phase failure and load unbalance detection.
  • It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling.
  • Settings are protected by a transparent cover lockable by sealing.
  • Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95.
  • Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately).
  • Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine),

Key Features

  • Ensure high safty with phase failure and load unbalance detection
  • The thermal adjustement dial enables accurate and reliable operation
  • It is designed with a transparent cover lockable by sealing in case of misoperation
  • Simple mounting on DIN rail or screw fixing
  • Sustainability compliant

Technical Specifications

Main10
RangeTeSys
Product NameTeSys LRD; TeSys Deca
Product Or Component TypeDifferential thermal overload relay
Device Short NameLRD
Relay ApplicationMotor protection
Product CompatibilityLC1D95; LC1D80
Network TypeAC; DC
Thermal Overload ClassClass 10A conforming to IEC 60947-4-1
Thermal Protection Adjustment Range80…104 A
[Ui] Rated Insulation VoltagePower circuit: 1000 V conforming to IEC 60947-4-1; Power circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL
Complementary18
Network Frequency0...400 Hz
Mounting SupportPlate, with specific accessories; Rail, with specific accessories; Under contactor
Tripping Threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary Contact Composition1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current5 A for signalling circuit
Permissible Current0.72 A at 500 V AC-15 for signalling circuit; 0.06 A at 440 V DC-13 for signalling circuit
[Ue] Rated Operational Voltage1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Associated Fuse Rating4 A gG for signalling circuit; 4 A BS for signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-1
Phase Failure SensitivityTripping current 130 % of Ir on two phase, the last one at 0
Control TypeRed push-button: stop; Blue push-button: reset
Temperature Compensation-20…60 °C
Connections - TerminalsPower circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible without cable end; Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible with cable end; Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² solid without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end; Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² fle
Tightening TorqueControl circuit: 1.7 N.m - on screw clamp terminals; Power circuit: 9 N.m - on screw clamp terminals
Height81 mm
Width70 mm
Depth115 mm
Net Weight0.51 kg
Environment9
Climatic Withstandconforming to IACS E10
IP Degree Of ProtectionIP20 conforming to IEC 60529
Ambient Air Temperature For Operation-20…60 °C without derating conforming to IEC 60947-4-1
Ambient Air Temperature For Storage-60…70 °C
Flame RetardanceV1 conforming to UL 94
Mechanical RobustnessVibrations: 6 Gn conforming to IEC 60068-2-6; Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric Strength2.2 kV at 50 Hz conforming to IEC 60947-1
StandardsEN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; GB/T 14048.4; GB/T 14048.5; EN 50495
Product CertificationsIEC; UL; CSA; CCC; EAC; ATEX INERIS; UKCA
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height7.800 cm
Package 1 Width12.000 cm
Package 1 Length8.600 cm
Package 1 Weight543.000 g
Unit Type Of Package 2S02
Number Of Units In Package 212
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.815 kg
Unit Type Of Package 3P06
Number Of Units In Package 3192
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight122.363 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.