Schneider LTMTEFM - TeSys Tera Main Module EtherNet 100-240VAC/DC
Schneider

LTMTEFM - TeSys Tera Main Module EtherNet 100-240VAC/DC

Schneider LTMTEFM, TeSys Tera Main Module EtherNet 100-240VAC/DC. Category: TeSys Tera. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Product Name
TeSys Tera
Device Short Name
LTMT
Product Or Component Type
Motor controller

Product Description

  • TeSys Tera Motor Management system and protection system is designed to provide high performance, efficiency, and connectivity.
  • And provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors up to 810A.
  • TeSys Tera is a flexible system that integrates seamlessly into your automation system through five major communication protocols.
  • TeSys Tera Helps to reduce operating costs and downtime with advanced diagnostics and analytics.
  • This controller is the central component in the motor management system.
  • Advance notice of potential issues through intuitive pre-trip alarming, It provides complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors
  • It provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors via integral Sensor modules from 0.3 to 100A and upto 810A by using external current transformers.
  • It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions.
  • Ethernet IP/modbus TCP is used by this controller. EtherNet TCP/IP communication is used.
  • This module has 6 discrete logic inputs.
  • The current range of this controller is 0.3 to 8 amperes.
  • 100 to 240VAC/DC is used to power this controller.
  • Controller has the following certifications: IEC, UL, cUL.

Key Features

  • Current and voltage-based protections
  • Motor parameters monitoring and protection
  • Ethernet TCP/IP Communication
  • 85 to 265V AC Control voltage
  • HSR support for ring redundancy

Technical Specifications

Main10
RangeTeSys
Product NameTeSys Tera
Device Short NameLTMT
Product Or Component TypeMotor controller
Device ApplicationEquipment monitoring and control
[Us] Rated Supply Voltage100...240 V AC/DC 50/60 Hz
Current Consumption8...62.8 mA
Supply Voltage Limits85…265 V AC/DC
Communication Port ProtocolEthernet TCP/IP
Bus TypeEthernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, 2xRJ45 with 4 shielding pairs cable
Complementary25
[Ui] Rated Insulation Voltage690 V AC conforming to IEC 60185
Short-circuit Withstand100 kA
Pollution Degree3
Overvoltage CategoryIII
[Uimp] Rated Impulse Withstand Voltage4 kV
Associated Fuse Rating0.5 A gG for control circuit
Protection TypeOverload protection; Stalled rotor; Locked rotor; Short-circuit; Undercurrent; Overcurrent; Current unbalance; Phase reversal; Phase loss; Earth fault protection internal; Earth fault protection external; Excessive starting time; Max number of start; Undervoltage; Overvoltage; Voltage unbalance; Underfrequency; Overfrequency; Reacceleration; Temperature protection; Analog input protection; Communi
Network And Machine Diagnosis TypeMotor statistics; Motor status; Event recording; Running hours counter/operating time; Number of starts and stops; Running hours /stop hours counter; Start curve showing motor start record; Pre-alarms; Trip history information; Alarm counters
Logic Input Number4
Input Current3 mA at 100...240 V
Current State 0 GuaranteedDigital input: 0...12 V and 5 mA for 10 ms
Current State 1 GuaranteedDigital input: 85...265 V and 5 mA for 10 ms
Maximum Output Switching Frequency2 Hz
Load Current10 A at 250 V AC/DC; 5 A at 30 V DC
Permissible Power480 VA (AC-15), Ie = 2 A, 500000 cycles (output); 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum Operating Rate1800 cyc/h
Contacts Type And Composition2 NO fault signal; 1 NO + 1 NC fault signal
Metering TypeThermal memory; Line, phase and average current; Line to line and average voltage; Motor temperature input; Ground fault current Ig; Active and reactive power; Active and reactive energy; Frequency; Total voltage harmonic distortion THD (V); Total voltage harmonic distortion THD (U); Total current harmonic distortion THD (I); Phase sequence
Measurement Accuracy1 % current (0.3...3 A); 1 % current (2.5...25 A); 3 % current (7...70 A); 3 % current (10...100 A); 1 % voltage (110...690 V); +/- 2.5 % earth fault current external measurement; +/- 3...5 % earth fault current internal measurement (current > 0.03 A in the 0.3...3 A range); +/- 3...5 % earth fault current internal measurement (current > 0.25 A in the 2.5...25 A range); +/- 3...5 % earth fault cur
Connection Pitch7.5 mm for supply voltage; 5.0 mm for others
Connections - TerminalsControl circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable
Width112 mm
Height45 mm
Depth90 mm
Web ServicesWeb server
Environment8
StandardsEN/IEC 60947-4-1; UL/CSA 60947-4-1
Product CertificationsUL; IEC; cUL
Fire Resistance650 °C conforming to IEC 60947-1; 960 °C conforming to UL 94
Ambient Air Temperature For Operation-20…70 °C
Ambient Air Temperature For Storage-40…80 °C
Operating Altitude<= 2000 m without derating
Mechanical RobustnessVibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-27; Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP Degree Of ProtectionIP20
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.100 cm
Package 1 Width10.000 cm
Package 1 Length13.500 cm
Package 1 Weight302.000 g
Unit Type Of Package 2S01
Number Of Units In Package 24
Package 2 Height15.000 cm
Package 2 Width15.000 cm
Package 2 Length40.000 cm
Package 2 Weight1.482 kg
Logistical informations1
Country Of OriginIN
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents1

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support