Schneider
LTMTEFM - TeSys Tera Main Module EtherNet 100-240VAC/DC
Schneider LTMTEFM, TeSys Tera Main Module EtherNet 100-240VAC/DC. Category: TeSys Tera. Request a quote for price and lead time.
- Reference:LTMTEFM
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:1,408.05 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Product Name
- TeSys Tera
- Device Short Name
- LTMT
- Product Or Component Type
- Motor controller
Product Description
- TeSys Tera Motor Management system and protection system is designed to provide high performance, efficiency, and connectivity.
- And provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors up to 810A.
- TeSys Tera is a flexible system that integrates seamlessly into your automation system through five major communication protocols.
- TeSys Tera Helps to reduce operating costs and downtime with advanced diagnostics and analytics.
- This controller is the central component in the motor management system.
- Advance notice of potential issues through intuitive pre-trip alarming, It provides complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors
- It provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors via integral Sensor modules from 0.3 to 100A and upto 810A by using external current transformers.
- It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions.
- Ethernet IP/modbus TCP is used by this controller. EtherNet TCP/IP communication is used.
- This module has 6 discrete logic inputs.
- The current range of this controller is 0.3 to 8 amperes.
- 100 to 240VAC/DC is used to power this controller.
- Controller has the following certifications: IEC, UL, cUL.
Key Features
- Current and voltage-based protections
- Motor parameters monitoring and protection
- Ethernet TCP/IP Communication
- 85 to 265V AC Control voltage
- HSR support for ring redundancy
Technical Specifications
Main10
| Range | TeSys |
|---|---|
| Product Name | TeSys Tera |
| Device Short Name | LTMT |
| Product Or Component Type | Motor controller |
| Device Application | Equipment monitoring and control |
| [Us] Rated Supply Voltage | 100...240 V AC/DC 50/60 Hz |
| Current Consumption | 8...62.8 mA |
| Supply Voltage Limits | 85…265 V AC/DC |
| Communication Port Protocol | Ethernet TCP/IP |
| Bus Type | Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, 2xRJ45 with 4 shielding pairs cable |
Complementary25
| [Ui] Rated Insulation Voltage | 690 V AC conforming to IEC 60185 |
|---|---|
| Short-circuit Withstand | 100 kA |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV |
| Associated Fuse Rating | 0.5 A gG for control circuit |
| Protection Type | Overload protection; Stalled rotor; Locked rotor; Short-circuit; Undercurrent; Overcurrent; Current unbalance; Phase reversal; Phase loss; Earth fault protection internal; Earth fault protection external; Excessive starting time; Max number of start; Undervoltage; Overvoltage; Voltage unbalance; Underfrequency; Overfrequency; Reacceleration; Temperature protection; Analog input protection; Communi |
| Network And Machine Diagnosis Type | Motor statistics; Motor status; Event recording; Running hours counter/operating time; Number of starts and stops; Running hours /stop hours counter; Start curve showing motor start record; Pre-alarms; Trip history information; Alarm counters |
| Logic Input Number | 4 |
| Input Current | 3 mA at 100...240 V |
| Current State 0 Guaranteed | Digital input: 0...12 V and 5 mA for 10 ms |
| Current State 1 Guaranteed | Digital input: 85...265 V and 5 mA for 10 ms |
| Maximum Output Switching Frequency | 2 Hz |
| Load Current | 10 A at 250 V AC/DC; 5 A at 30 V DC |
| Permissible Power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output); 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| Maximum Operating Rate | 1800 cyc/h |
| Contacts Type And Composition | 2 NO fault signal; 1 NO + 1 NC fault signal |
| Metering Type | Thermal memory; Line, phase and average current; Line to line and average voltage; Motor temperature input; Ground fault current Ig; Active and reactive power; Active and reactive energy; Frequency; Total voltage harmonic distortion THD (V); Total voltage harmonic distortion THD (U); Total current harmonic distortion THD (I); Phase sequence |
| Measurement Accuracy | 1 % current (0.3...3 A); 1 % current (2.5...25 A); 3 % current (7...70 A); 3 % current (10...100 A); 1 % voltage (110...690 V); +/- 2.5 % earth fault current external measurement; +/- 3...5 % earth fault current internal measurement (current > 0.03 A in the 0.3...3 A range); +/- 3...5 % earth fault current internal measurement (current > 0.25 A in the 2.5...25 A range); +/- 3...5 % earth fault cur |
| Connection Pitch | 7.5 mm for supply voltage; 5.0 mm for others |
| Connections - Terminals | Control circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable |
| Width | 112 mm |
| Height | 45 mm |
| Depth | 90 mm |
| Web Services | Web server |
Environment8
| Standards | EN/IEC 60947-4-1; UL/CSA 60947-4-1 |
|---|---|
| Product Certifications | UL; IEC; cUL |
| Fire Resistance | 650 °C conforming to IEC 60947-1; 960 °C conforming to UL 94 |
| Ambient Air Temperature For Operation | -20…70 °C |
| Ambient Air Temperature For Storage | -40…80 °C |
| Operating Altitude | <= 2000 m without derating |
| Mechanical Robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-27; Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
| IP Degree Of Protection | IP20 |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 5.100 cm |
| Package 1 Width | 10.000 cm |
| Package 1 Length | 13.500 cm |
| Package 1 Weight | 302.000 g |
| Unit Type Of Package 2 | S01 |
| Number Of Units In Package 2 | 4 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.482 kg |
Logistical informations1
| Country Of Origin | IN |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.