Schneider LTMTMFM - TeSys Tera Main Module Modbus 100-240VAC/DC
Schneider

LTMTMFM - TeSys Tera Main Module Modbus 100-240VAC/DC

Schneider LTMTMFM, TeSys Tera Main Module Modbus 100-240VAC/DC. Category: TeSys Tera. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Product Name
TeSys Tera
Device Short Name
LTMT
Product Or Component Type
Motor controller

Product Description

TeSys Tera Motor Management system and protection system is designed to provide high performance, efficiency, and connectivity. 100 to 240VAC/DC is used to power this controller. Modbus RTU protocol with Modbus RTU communication. This module has 4 digital inputs and 3 digital outputs. Baud Rate: 4800 to 115200 bit/s Read/Write function code Device Diagnosis. And provide complete protection, control, and monitoring capabilities for single-phase and three-phase AC induction motors up to 810A. Advance notice of potential issues through intuitive pre-trip alarming. Connection via a communication network. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Controller has the following certifications: IEC, UL, cUL.

Key Features

  • Current and voltage-based protections
  • Motor parameters monitoring and protection
  • Modbus RTU Communication protocol
  • 85 to 265V AC Control voltage
  • Baud Rate: 4800 to 115200 bit/sec

Technical Specifications

Main10
RangeTeSys
Product NameTeSys Tera
Device Short NameLTMT
Product Or Component TypeMotor controller
Device ApplicationEquipment monitoring and control
[Us] Rated Supply Voltage100...240 V AC/DC 50/60 Hz
Current Consumption8...62.8 mA
Supply Voltage Limits85…265 V AC/DC
Communication Port ProtocolModbus RTU
Bus TypeModbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs
Complementary26
[Ui] Rated Insulation Voltage250 V AC conforming to IEC 60185
Short-circuit Withstand100 kA
Pollution Degree3
Overvoltage CategoryIII
[Uimp] Rated Impulse Withstand Voltage4 kV
Associated Fuse Rating0.5 A gG for control circuit
Protection TypeOverload protection; Stalled rotor; Locked rotor; Short-circuit; Undercurrent; Overcurrent; Current unbalance; Phase reversal; Phase loss; Earth fault protection internal; Earth fault protection external; Excessive starting time; Max number of start; Undervoltage; Overvoltage; Voltage unbalance; Underfrequency; Overfrequency; Reacceleration; Temperature protection; Analog input protection; Communi
Network And Machine Diagnosis TypeMotor statistics; Motor status; Event recording; Running hours counter/operating time; Number of starts and stops; Running hours /stop hours counter; Start curve showing motor start record; Pre-alarms; Trip history information; Alarm counters
Logic Input Number4
Input Current3 mA at 100...240 V
Current State 0 GuaranteedDigital input: 0...12 V and 5 mA for 10 ms
Current State 1 GuaranteedDigital input: 85...265 V and 5 mA for 10 ms
Maximum Output Switching Frequency2 Hz
Load Current10 A at 250 V AC/DC; 5 A at 30 V DC
Permissible Power480 VA (AC-15), Ie = 2 A, 500000 cycles (output); 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Maximum Operating Rate1800 cyc/h
Contacts Type And Composition1 NO + 1 NC fault signal; 3 NO
Metering TypeThermal memory; Line, phase and average current; Line to line and average voltage; Motor temperature input; Ground fault current Ig; Active and reactive power; Active and reactive energy; Frequency; Total voltage harmonic distortion THD (V); Total voltage harmonic distortion THD (U); Total current harmonic distortion THD (I); Phase sequence
Measurement Accuracy1 % current (0.3...3 A); 1 % current (2.5...25 A); 3 % current (7...70 A); 3 % current (10...100 A); 1 % voltage (110...690 V); +/- 2.5 % earth fault current external measurement; +/- 3...5 % earth fault current internal measurement (current > 0.03 A in the 0.3...3 A range); +/- 3...5 % earth fault current internal measurement (current > 0.25 A in the 2.5...25 A range); +/- 3...5 % earth fault cur
Connection Pitch7.5 mm for supply voltage; 5.0 mm for others
Connections - TerminalsControl circuit: connector 1 cable(s) 0.2…2.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible without cable end; Control circuit: connector 1 cable(s) 0.25…2.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable end; Control circuit: connector 2 cable(s) 0.2…1.5 mm² (24 AWG...14 AWG) flexible with ferrule with cable
Tightening TorqueControl circuit: 0.5 N.m - with screwdriver flat 3 mm
Width112 mm
Height45 mm
Depth90 mm
Web ServicesWeb server
Environment8
StandardsEN/IEC 60947-4-1; UL/CSA 60947-4-1
Product CertificationsUL; IEC; cUL
Fire Resistance650 °C conforming to IEC 60947-1; 960 °C conforming to UL 94
Ambient Air Temperature For Operation-20…70 °C
Ambient Air Temperature For Storage-40…80 °C
Operating Altitude<= 2000 m without derating
Mechanical RobustnessVibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-27; Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6; Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
IP Degree Of ProtectionIP20
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height10.000 cm
Package 1 Width5.000 cm
Package 1 Length13.200 cm
Package 1 Weight290.000 g
Unit Type Of Package 2S01
Number Of Units In Package 24
Package 2 Height15.000 cm
Package 2 Width15.000 cm
Package 2 Length40.000 cm
Package 2 Weight1.412 kg
Logistical informations1
Country Of OriginIN
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents1

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support