Schneider LU2B32FU - TeSys U Advanced Power Base 3P 32A 110-220VAC/DC
Schneider

LU2B32FU - TeSys U Advanced Power Base 3P 32A 110-220VAC/DC

Schneider LU2B32FU, TeSys U Advanced Power Base 3P 32A 110-220VAC/DC. Category: TeSys Ultra. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Product Name
TeSys Ultra
Device Short Name
LU2B
Product Or Component Type
Reversing power base

Product Description

  • TeSys U standard reversing power base, 3 poles (3NO), rated 32A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V.
  • Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a "all in one" reversing starter controller with basic or advanced protection and control functions.
  • It is equipped with a reverser module LU2MB0FU to be supplied with 110-240V AC / 110-220V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities.
  • It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour.
  • Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle.
  • Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine)

Key Features

  • "Protection against overload and short-circuit"
  • "Control unit includes electronic components and the current adjustment dial"
  • "Modular, plug & play structure helps you to perform quick maintenance"
  • "Direct access to detailed information for every motor starter of your installation"
  • "Advanced motor management system"

Technical Specifications

Main18
RangeTeSys
Product NameTeSys Ultra
Device Short NameLU2B
Product Or Component TypeReversing power base
Device ApplicationMotor control; Motor protection
Product CompatibilityControl unit LUC.X6FU; Control unit LUC.1XFU; Control unit LUC.05FU; Control unit LUC.12FU; Control unit LUC.18FU; Control unit LUC.32FU
Poles Description3P
Suitability For IsolationYes
[Ue] Rated Operational Voltage690 V AC for power circuit
Network Frequency40...60 Hz
[Ith] Conventional Free Air Thermal Current32 A
[Ie] Rated Operational Current32 A at <= 440 V; 23 A at 500 V; 21 A at 690 V
Utilisation CategoryAC-43; AC-44; AC-41
[Ics] Rated Service Breaking Capacity50 kA at 230 V; 50 kA at 440 V; 10 kA at 500 V; 4 kA at 690 V
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Typetype linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1; type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] Control Circuit Voltage110...240 V AC 50/60 Hz; 110...220 V DC
Control Circuit Voltage Limits55 V DC drop-out; 55 V AC drop-out; 88...242 V DC in operation; 88...264 V AC in operation
Complementary20
Typical Current Consumption1000 mA at 110...220 V DC I maximum while closing; 1000 mA at 110...240 V AC I maximum while closing
Heat Dissipation3 W for control circuit with LUCA, LUCB, LUCC, LUCD; 1.8 W for control circuit with LUCM
Inrush Restraint Duration25 ms AC 50/60 Hz; 15 ms DC
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating Time150 ms with change of direction for power circuit; 35 ms opening for control circuit; 75 ms without change of direction for power circuit; 50 ms closing for control circuit
Mechanical Durability15 Mcycles
Maximum Operating Rate3600 cyc/h
Product CertificationsCE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-6-2 (pollution degree 3); 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing ModeClipped (DIN rail); Screw-fixed (plate)
Connections - TerminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end; Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm²
Tightening TorqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
Width45 mm
Height224 mm
Depth126 mm
Net Weight1.27 kg
Compatibility CodeLU2B
Environment15
IP Degree Of ProtectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature For Storage-40…85 °C
Fire Resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating Altitude2000 m
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration Resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating Shock Wave1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Microbreaks3 ms for control circuit
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.500 cm
Package 1 Width15.000 cm
Package 1 Length25.500 cm
Package 1 Weight1.300 kg
Unit Type Of Package 2S03
Number Of Units In Package 29
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight12.250 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18