Schneider
LU2MB0ES - TeSys U Reversing Block 32A 48-72VAC/DC
Schneider LU2MB0ES, TeSys U Reversing Block 32A 48-72VAC/DC. Category: TeSys Ultra. Request a quote for price and lead time.
- Reference:LU2MB0ES
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:365.70 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Device Short Name
- LU2MB
- Product Or Component Type
- Reverser block
- Device Mounting
- Direct mounting
Product Description
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 48V AC / 48-72V DC. To be used with an advanced power base LUB120 or LUB320 equipped with a Control Unit LUC*ES type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. compliant (RoHS/REACh).
Key Features
- Protection against overload and short-circuit
- Control unit includes electronic components and the current adjustment dial
- Modular, plug & play structure helps you to perform quick maintenance
- Direct access to detailed information for every motor starter of your installation
- Advanced motor management system
Technical Specifications
Main8
| Range | TeSys |
|---|---|
| Device Short Name | LU2MB |
| Product Or Component Type | Reverser block |
| Device Mounting | Direct mounting |
| Device Application | Motor control |
| [Ie] Rated Operational Current | 32 A |
| [Uc] Control Circuit Voltage | 48 V AC 50/60 Hz; 48...72 V DC |
| Current Consumption | 2300 mA at 48 V AC I maximum while closing; 2300 mA at 48...72 V DC I maximum while closing |
Complementary16
| [Ue] Rated Operational Voltage | 690 V AC power circuit |
|---|---|
| Network Frequency | 40...60 Hz |
| Inrush Restraint Duration | 25 ms AC; 15 ms DC |
| Operating Time | 150 ms with change of direction; 75 ms without change of direction |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier |
| Product Certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| [Ui] Rated Insulation Voltage | 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-6-2 |
| Fixing Mode | Plug-in |
| Connections - Terminals | Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² (external diameter: 3 mm) flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² (external |
| Tightening Torque | Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips No 2 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm |
| Width | 45 mm |
| Height | 80 mm |
| Depth | 105 mm |
| Net Weight | 0.4 kg |
| Compatibility Code | LU2MB |
Environment13
| IP Degree Of Protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
|---|---|
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature For Operation | -25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD |
| Ambient Air Temperature For Storage | -40…85 °C |
| Fire Resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12 |
| Operating Altitude | 2000 m |
| Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration Resistance | 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27 |
| Resistance To Electrostatic Discharge | 8 kV level 3, in open air conforming to IEC 61000-4-2; 8 kV level 4, on contact conforming to IEC 61000-4-2 |
| Resistance To Radiated Fields | 10 V/m level 3 conforming to IEC 61000-4-3 |
| Resistance To Fast Transients | 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Non-dissipating Shock Wave | 1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2 |
| Immunity To Radioelectric Fields | 10 V conforming to IEC 61000-4-6 |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 13 cm |
| Package 1 Width | 5.5 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 387 g |
| Unit Type Of Package 2 | S02 |
| Number Of Units In Package 2 | 12 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 4.959 kg |
Logistical informations1
| Country Of Origin | FR |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.