Schneider LU2MB0FU - TeSys U Reversing Block 32A 110-220VAC/DC
Schneider

LU2MB0FU - TeSys U Reversing Block 32A 110-220VAC/DC

Schneider LU2MB0FU, TeSys U Reversing Block 32A 110-220VAC/DC. Category: TeSys Ultra. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Device Short Name
LU2MB
Product Or Component Type
Reverser block
Device Mounting
Direct mounting

Product Description

TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. compliant (RoHS/REACh).

Key Features

  • "Protection against overload and short-circuit"
  • "Control unit includes electronic components and the current adjustment dial"
  • "Modular, plug & play structure helps you to perform quick maintenance"
  • "Direct access to detailed information for every motor starter of your installation"
  • "Advanced motor management system"

Technical Specifications

Main8
RangeTeSys
Device Short NameLU2MB
Product Or Component TypeReverser block
Device MountingDirect mounting
Device ApplicationMotor control
[Ie] Rated Operational Current38 A
[Uc] Control Circuit Voltage110...240 V AC 50/60 Hz; 110...220 V DC
Current Consumption1000 mA at 110...220 V DC I maximum while closing; 1000 mA at 110...240 V AC I maximum while closing
Complementary16
[Ue] Rated Operational Voltage690 V AC power circuit
Network Frequency40...60 Hz
Inrush Restraint Duration25 ms AC; 15 ms DC
Operating Time150 ms with change of direction; 75 ms without change of direction
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
Product CertificationsCE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
Fixing ModePlug-in
Connections - TerminalsControl circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² (external diameter: 3 mm) flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² (external
Tightening TorqueControl circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips No 2 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Width45 mm
Height80 mm
Depth105 mm
Net Weight0.4 kg
Compatibility CodeLU2MB
Environment13
IP Degree Of ProtectionIP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature For Storage-40…85 °C
Fire Resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Operating Altitude2000 m
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration Resistance2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
Resistance To Electrostatic Discharge8 kV level 3, in open air conforming to IEC 61000-4-2; 8 kV level 4, on contact conforming to IEC 61000-4-2
Resistance To Radiated Fields10 V/m level 3 conforming to IEC 61000-4-3
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Non-dissipating Shock Wave1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.7 cm
Package 1 Width9.5 cm
Package 1 Length13.0 cm
Package 1 Weight396.0 g
Unit Type Of Package 2S02
Number Of Units In Package 212
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.048 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support