Schneider
LU6MB0BL - TeSys U Reversing Block 32A 24VDC
Schneider LU6MB0BL, TeSys U Reversing Block 32A 24VDC. Category: TeSys Ultra. Request a quote for price and lead time.
- Reference:LU6MB0BL
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:368.00 EUR (Request a quote)
Key Specifications
- Range
- TeSys
- Device Short Name
- LU6MB
- Product Or Component Type
- Reverser block
- Device Mounting
- Separate mounting
Product Description
TeSys U reversing module for side mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 24 DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*BL type. To be associated with an assembling connector LU9MR1 and a control terminal block LU9M1 to complete the side mounting. compliant (RoHS/REACh).
Key Features
- "Protection against overload and short-circuit"
- "Control unit includes electronic components and the current adjustment dial"
- "Modular, plug & play structure helps you to perform quick maintenance"
- "Direct access to detailed information for every motor starter of your installation"
- "Advanced motor management system"
Technical Specifications
Main8
| Range | TeSys |
|---|---|
| Device Short Name | LU6MB |
| Product Or Component Type | Reverser block |
| Device Mounting | Separate mounting |
| Device Application | Motor control |
| [Ie] Rated Operational Current | 38 A |
| [Uc] Control Circuit Voltage | 24 V DC |
| Current Consumption | 120 mA at 24 V DC I maximum while closing; 120 mA at 24 V DC I rms sealed |
Complementary16
| [Ue] Rated Operational Voltage | 690 V AC power circuit |
|---|---|
| Network Frequency | 40...60 Hz |
| Inrush Restraint Duration | 25 ms AC; 15 ms DC |
| Operating Time | 150 ms with change of direction; 75 ms without change of direction |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier |
| Product Certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| [Ui] Rated Insulation Voltage | 690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-6-2 |
| Fixing Mode | Clipped (DIN rail); Screw-fixed (plate) |
| Connections - Terminals | Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² (external diameter: 3 mm) flexible with cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) flexible without cable end; Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² (external diameter: 3 mm) rigid; Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² (external |
| Tightening Torque | Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm; Control circuit: 0.8…1.2 N.m Philips No 2 screwdriver 5 mm; Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm; Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm; Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm |
| Width | 45 mm |
| Height | 115 mm |
| Depth | 113 mm |
| Net Weight | 0.425 kg |
| Compatibility Code | LU6MB |
Environment12
| IP Degree Of Protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals); IP20 conforming to IEC 60947-1 (other faces); IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
|---|---|
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature For Operation | -25…60 °C with LUCM; -25…70 °C with LUCA, LUCB, LUCC, LUCD |
| Ambient Air Temperature For Storage | -40…85 °C |
| Fire Resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12 |
| Operating Altitude | 2000 m |
| Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration Resistance | 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27; 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27 |
| Resistance To Electrostatic Discharge | 8 kV level 3, in open air conforming to IEC 61000-4-2; 8 kV level 4, on contact conforming to IEC 61000-4-2 |
| Resistance To Radiated Fields | 10 V/m level 3 conforming to IEC 61000-4-3 |
| Resistance To Fast Transients | 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Immunity To Radioelectric Fields | 10 V conforming to IEC 61000-4-6 |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 14.300 cm |
| Package 1 Width | 5.800 cm |
| Package 1 Length | 13.100 cm |
| Package 1 Weight | 448.000 g |
| Unit Type Of Package 2 | S02 |
| Number Of Units In Package 2 | 10 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.705 kg |
Logistical informations1
| Country Of Origin | FR |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.