Schneider LUCB05FU - TeSys U Advanced Control Unit 1.25-5A 110-220VAC/DC
Schneider

LUCB05FU - TeSys U Advanced Control Unit 1.25-5A 110-220VAC/DC

Schneider LUCB05FU, TeSys U Advanced Control Unit 1.25-5A 110-220VAC/DC. Category: TeSys Ultra. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Range Of Product
TeSys Ultra
Product Name
TeSys Ultra
Device Short Name
LUCB

Product Description

  • TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 1.5kW@400V.
  • It provides full protection to motors with a rated current Ir 1.25-5A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only).
  • It provides a thermal overload alarm to be used locally using a LUFDA module or remotely using a LULC module, and a test push button for overload simulation.
  • To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).
  • Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine),

Key Features

  • "Protection against overload and short-circuit"
  • "Control unit includes electronic components and the current adjustment dial"
  • "Modular, plug & play structure helps you to perform quick maintenance"
  • "Direct access to detailed information for every motor starter of your installation"
  • "Advanced motor management system"

Technical Specifications

Main19
RangeTeSys
Range Of ProductTeSys Ultra
Product NameTeSys Ultra
Device Short NameLUCB
Product Or Component TypeAdvanced control unit
Device ApplicationMotor control; Motor protection
Product Specific ApplicationBasic protection and advanced functions, communication
Main Function AvailableProtection against overload and short-circuit; Earth fault protection; Protection against phase failure and phase imbalance; Manual reset
Product CompatibilityPower base LUB12; Power base LUB32; Power base LUB38; Power base LUB120; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B12FU; Reversing contactor breaker LU2B32FU; Reversing contactor breaker LU2B38FU
[Ue] Rated Operational Voltage690 V AC
Network Frequency40...60 Hz
Load Type3-phase motor - cooling: self-cooled
Utilisation CategoryAC-41; AC-44; AC-43
Motor Power KW1.5 kW at 400...440 V AC 50/60 Hz; 2.2 kW at 500 V AC 50/60 Hz; 3 kW at 690 V AC 50/60 Hz
Rated Motor Current Adjustment Range1.25…5 A
Thermal Overload ClassClass 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2; Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508
Tripping Threshold14.2 x Ir +/- 20 %
Phase Failure SensitivityYes
[Uc] Control Circuit Voltage110...240 V AC; 110...220 V DC
Complementary15
Control Circuit Voltage Limits88...264 V for AC circuit 110...240 V in operation; 88...242 V for DC circuit 110...220 V in operation; 55 V for AC circuit 110...240 V drop-out; 55 V for DC circuit 110...220 V drop-out
Typical Current Consumption280 mA at 110...240 V AC I maximum while closing with LUB12; 280 mA at 110...240 V AC I maximum while closing with LUB32; 280 mA at 110...240 V AC I maximum while closing with LUB38; 280 mA at 110...220 V DC I maximum while closing with LUB12; 280 mA at 110...220 V DC I maximum while closing with LUB32; 280 mA at 110...220 V DC I maximum while closing with LUB38; 35 mA at 110...240 V AC I rms seal
Heat Dissipation2 W for control circuit with LUB12; 3 W for control circuit with LUB32; 3 W for control circuit with LUB38
Operating Time35 ms opening with LUB12 for control circuit; 35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 50 ms closing with LUB12 for control circuit; 50 ms closing with LUB32 for control circuit; 50 ms closing with LUB38 for control circuit
ResetManual reset
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
Product CertificationsCE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing ModePlug-in (front face)
Width45 mm
Height66 mm
Depth60 mm
Compatibility CodeLUCB
Environment15
IP Degree Of ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-25…70 °C
Ambient Air Temperature For Storage-40…85 °C
Operating Altitude2000 m
Fire Resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration Resistance2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating Shock Wave1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.000 cm
Package 1 Width8.100 cm
Package 1 Length8.700 cm
Package 1 Weight119.000 g
Unit Type Of Package 2S02
Number Of Units In Package 223
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight2.994 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2