Schneider LUCL32B - TeSys U Standard Control Unit 3P 8-32A 24VAC
Schneider

LUCL32B - TeSys U Standard Control Unit 3P 8-32A 24VAC

Schneider LUCL32B, TeSys U Standard Control Unit 3P 8-32A 24VAC. Category: TeSys Ultra. Request a quote for price and lead time.

Key Specifications

Range
TeSys
Range Of Product
TeSys Ultra
Product Name
TeSys Ultra
Device Short Name
LUCL

Product Description

  • TeSys U magnetic control unit to be inserted in power bases LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V.
  • It provides short circuit protection to motors with a rated current In 8-32A (In adjustable by dial), overcurrent protection level at 14.2 x In.
  • To be used when a power base is connected to a motor drive or a soft starter providing overload protection.
  • To be used with a 24V AC voltage for the control of the starter (through the control terminals A1/A2 located in the power base).
  • Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine),

Key Features

  • "Protection against overload and short-circuit"
  • "Control unit includes electronic components and the current adjustment dial"
  • "Modular, plug & play structure helps you to perform quick maintenance"
  • "Direct access to detailed information for every motor starter of your installation"
  • "Advanced motor management system"

Technical Specifications

Main17
RangeTeSys
Range Of ProductTeSys Ultra
Product NameTeSys Ultra
Device Short NameLUCL
Product Or Component TypeMagnetic control unit
Device ApplicationMotor control; Motor protection
Product Specific ApplicationProtection of variable speed drive or soft startsoft stop unit
Main Function AvailableManual reset; Short-circuit protection
Product CompatibilityPower base LUB32; Power base LUB38; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B32B
[Ue] Rated Operational Voltage690 V AC
Network Frequency40...60 Hz
Load Type3-phase motor - cooling: self-cooled
Utilisation CategoryAC-43; AC-44; AC-41
Motor Power KW15 kW at 400...440 V AC 50/60 Hz; 15 kW at 500 V AC 50/60 Hz; 18.5 kW at 690 V AC 50/60 Hz
Rated Motor Current Adjustment Range8…32 A
Tripping Threshold14.2 x Ir +/- 20 %
[Uc] Control Circuit Voltage24 V AC
Complementary15
Control Circuit Voltage Limits20...26.5 V for AC circuit 24 V in operation; 14.5 V for AC circuit 24 V drop-out
Typical Current Consumption220 mA at 24 V AC I maximum while closing with LUB32; 220 mA at 24 V AC I maximum while closing with LUB38; 90 mA at 24 V AC I rms sealed with LUB32; 90 mA at 24 V AC I rms sealed with LUB38
Heat Dissipation3 W for control circuit with LUB32; 3 W for control circuit with LUB38
Operating Time35 ms opening with LUB32 for control circuit; 35 ms opening with LUB38 for control circuit; 70 ms closing with LUB32 for control circuit; 70 ms closing with LUB38 for control circuit
StandardsEN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier
Product CertificationsCE; EAC; ATEX
[Ui] Rated Insulation Voltage690 V conforming to IEC 60947-6-2; 600 V conforming to UL 60947-4-1; 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Fixing ModePlug-in (front face)
Width45 mm
Height66 mm
Depth60 mm
Net Weight0.135 kg
Compatibility CodeLUCL
Environment15
IP Degree Of ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1
Protective TreatmentTH conforming to IEC 60068
Ambient Air Temperature For Operation-25…70 °C
Ambient Air Temperature For Storage-40…85 °C
Operating Altitude2000 m
Fire Resistance960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27
Vibration Resistance2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2
Non-dissipating Shock Wave1 kV serial mode conforming to IEC 60947-6-2; 2 kV common mode conforming to IEC 60947-6-2
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height5.5 cm
Package 1 Width8.0 cm
Package 1 Length10.0 cm
Package 1 Weight133.0 g
Unit Type Of Package 2S02
Number Of Units In Package 223
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight3.417 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads