Schneider LVR05500A40T - Reactor 5.67% 50kVAR 400V
Schneider

LVR05500A40T - Reactor 5.67% 50kVAR 400V

Schneider LVR05500A40T, Reactor 5.67% 50kVAR 400V. Category: SAH detuned reactors. Request a quote for price and lead time.

Key Specifications

Range
PowerLogic
Device Short Name
DR
Product Or Component Type
Detuned reactor
Network Frequency
50 Hz

Product Description

The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 50 kVar output power with 4.2/210 Hz tuning order at 400V AC at 50 Hz. Relative impedance, 5.7 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 270mm in height, 260mm in width and 200mm in depth. For a product weight of 24 kg.

Key Features

  • Low voltage PFC Detuned Reactor for stringent operating condition
  • Detuned reactor for harmonic attenuation
  • Best in class performance, safety and reliability
  • Vertical winding for better heat dissipation

Technical Specifications

Main7
RangePowerLogic
Device Short NameDR
Product Or Component TypeDetuned reactor
Network Frequency50 Hz
Reactive Power Rating50 kvar for 400 V AC 50 Hz
Network Rated Voltage400 V AC 50 Hz
Tuning Order4.2 - 210 Hz - 5.7 % - 50 Hz
Complementary20
Power Losses (max)320 W
Value Of Inductance0.614 mH
Inductance Tolerance- 5 % to 5 % per phase
Fundamental Current Rating72.2 A
RMS Current Rating88 A
Electrical Insulation ClassClass H
[Ui] Rated Insulation Voltage1.1 kV
Dielectric Test Voltage4 kV 50 Hz 1 minute
[Imp] Maximum Permanent Current1.3 x I1
Harmonic Current Spectrum2.9 % x I3; 67.8 % x I5; 18.6 % x I7; 6.2 % x I11
Dynamic Withstand Current2.2 x Isc
[Ith] Conventional Free Air Thermal Current2 A at 250 V AC 50 Hz
Type Of InstallationIndoor installation
Type Of CoolingForced convection
Connections - TerminalsPad terminal
Fixing Center200 x 125 mm
Height270 mm
Width260 mm
Depth200 mm
Net Weight24 kg
Environment6
StandardsIEC 60068
IP Degree Of ProtectionIP00
Operating Altitude<= 2000 m
Ambient Air Temperature For Operation0…55 °C at <= 1000 m; 0…50 °C at > 1000...2000 m
Average Ambient Air Temperature For Operation50 °C at <= 1000 m (average over 24 hours); 40 °C at <= 1000 m (average over 1 year); 45 °C at > 1000...2000 m (average over 24 hours); 35 °C at > 1000...2000 m (average over 1 year)
Climatic WithstandRelative humidity: 20...80 %; Salt mist (400 V/50 Hz) : 250 hours
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height48.000 cm
Package 1 Width40.000 cm
Package 1 Length60.000 cm
Package 1 Weight31.000 kg
Unit Type Of Package 2P06
Number Of Units In Package 22
Package 2 Height70.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight69.000 kg
Logistical informations1
Country Of OriginCZ
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents3

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support