LVR14065A40T - Reactor 14% 6.5kVAR 400V
Schneider LVR14065A40T, Reactor 14% 6.5kVAR 400V. Category: SAH detuned reactors. Request a quote for price and lead time.
- Reference:LVR14065A40T
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:795.00 EUR (Request a quote)
Key Specifications
- Range
- PowerLogic
- Device Short Name
- DR
- Product Or Component Type
- Detuned reactor
- Network Frequency
- 50 Hz
Product Description
The VarPlus detuned reactor are designed to protect the capacitor by preventing the amplification of the harmonics present in the system. Capacitors and Reactors are configured in Series resonant circuit. Tuned so that the series resonant frequency is below the lowest harmonic frequency present in the system. This reactor is rated for 6.5 kVar output power with 2.7/135 Hz tuning order at 400V AC at 50 Hz. Relative impedance, 14 %. This component meet the standards IEC 60068. This component require a forced convection, a fan need to be added. The case dimensions are 220mm in height, 240mm in width and 160mm in depth. For a product weight of 10 kg.
Key Features
- "Low voltage PFC Detuned Reactor for stringent operating condition"
- "Detuned reactor for harmonic attenuation"
- "Best in class performance, safety and reliability"
- "Vertical winding for better heat dissipation"
Technical Specifications
Main7
| Range | PowerLogic |
|---|---|
| Device Short Name | DR |
| Product Or Component Type | Detuned reactor |
| Network Frequency | 50 Hz |
| Reactive Power Rating | 6.5 kvar for 400 V AC 50 Hz |
| Network Rated Voltage | 400 V AC 50 Hz |
| Tuning Order | 2.7 - 135 Hz - 14 % - 50 Hz |
Complementary20
| Power Losses (max) | 100 W |
|---|---|
| Value Of Inductance | 11.439 mH |
| Inductance Tolerance | - 5 % to 5 % per phase |
| Fundamental Current Rating | 9.4 A |
| RMS Current Rating | 9.6 A |
| Electrical Insulation Class | Class H |
| [Ui] Rated Insulation Voltage | 1.1 kV |
| Dielectric Test Voltage | 4 kV 50 Hz 1 minute |
| [Imp] Maximum Permanent Current | 1.12 x I1 |
| Harmonic Current Spectrum | 5.5 % x I3; 10.7 % x I5; 5.3 % x I7; 2.1 % x I11 |
| Dynamic Withstand Current | 2.2 x Isc |
| [Ith] Conventional Free Air Thermal Current | 2 A at 250 V AC 50 Hz |
| Type Of Installation | Indoor installation |
| Type Of Cooling | Forced convection |
| Connections - Terminals | Pad terminal |
| Fixing Center | 200 x 125 mm |
| Height | 220 mm |
| Width | 240 mm |
| Depth | 160 mm |
| Net Weight | 10 kg |
Environment6
| Standards | IEC 60068 |
|---|---|
| IP Degree Of Protection | IP00 |
| Operating Altitude | <= 2000 m |
| Ambient Air Temperature For Operation | 0…55 °C at <= 1000 m; 0…50 °C at > 1000...2000 m |
| Average Ambient Air Temperature For Operation | 50 °C at <= 1000 m (average over 24 hours); 40 °C at <= 1000 m (average over 1 year); 45 °C at > 1000...2000 m (average over 24 hours); 35 °C at > 1000...2000 m (average over 1 year) |
| Climatic Withstand | Relative humidity: 20...80 %; Salt mist (400 V/50 Hz) : 250 hours |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 24.000 cm |
| Package 1 Width | 29.500 cm |
| Package 1 Length | 30.500 cm |
| Package 1 Weight | 10.110 kg |
| Unit Type Of Package 2 | P12 |
| Number Of Units In Package 2 | 12 |
| Package 2 Height | 50.000 cm |
| Package 2 Width | 80.000 cm |
| Package 2 Length | 120.000 cm |
| Package 2 Weight | 126.320 kg |
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads