Schneider METSEPM5340 - PM5340 Meter, ethernet, up to 31st H, 256K 2DI/2DO 35 alarms
Schneider

PM5340 Meter, ethernet, up to 31st H, 256K 2DI/2DO 35 alarms

Schneider METSEPM5340, PM5340 Meter, ethernet, up to 31st H, 256K 2DI/2DO 35 alarms. Category: PowerLogic PM5000. In stock.

Key Specifications

Range
PowerLogic
Product Name
PowerLogic PM5000
Product Or Component Type
Power meter
Device Short Name
PM5340

Product Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol are Modbus TCP/IP and BACnet/IP based on 10/100 Mbit/s, Ethernet with RJ45 port support. The meter also has two digital inputs or digital outputs, configurable, and dual relay outputs. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).

Key Features

  • "Feature-rich power and energy meters"
  • "Digital input and output for WAGES monitoring and control relays"
  • "Modbus TCP/ IP Ethernet communication port for remote monitoring"
  • "Identify energy savings opportunties with precision accuracy of Class 0.5S"
  • "31st Hamronic measurement for Power Quality management"

Technical Specifications

Main4
RangePowerLogic
Product NamePowerLogic PM5000
Product Or Component TypePower meter
Device Short NamePM5340
Complementary34
Power Quality Analysisup to the 31st harmonic
Device ApplicationMulti-tariff; Power monitoring
Type Of MeasurementCurrent; Voltage; Frequency; Power factor; Energy; Active and reactive power
[Us] Rated Supply Voltage90...450 V AC 45...65 Hz; 100...300 V DC
Network Frequency60 Hz; 50 Hz
[In] Rated Current5 A; 1 A
Type Of Network3P; 1P + N; 3P + N
Maximum Power Consumption In VA11 VA at 415 V
Ride-through Time100 ms 120 V AC typical; 400 ms 230 V AC typical; 50 ms 125 V DC typical
Display TypeMonochrome graphic LCD
Display Resolution128 x 128 pixels
Sampling Rate64 samples/cycle
Measurement Current5…9000 mA
Analogue Input TypeVoltage (impedance 10 MOhm); Current (impedance <= 0.3 mOhm)
Measurement Voltage35…760 V AC 45...65 Hz between phases; 20…400 V AC 45...65 Hz between phase and neutral
Frequency Measurement Range45…65 Hz
Number Of Inputs2 digital
Measurement AccuracyActive energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.5; Current +/- 0.5 %; Voltage +/- 0.5 %; Apparent energy +/- 0.5 %; Reactive power +/- 2 %
Accuracy ClassClass 0.5S active energy conforming to IEC 62053-22
Number Of Outputs2 relay; 2 digital
Information DisplayedTariff (4)
Communication Port ProtocolModbus TCP/IP at 10/100 Mbit/s, insulation 2500 V; BACnet IP
Communication Port SupportETHERNET
Data RecordingData logs; Alarm logs; Time stamping; Event logs; Min/max of instantaneous values; Maintenance logs
Memory Capacity256 kB
Connections - TerminalsVoltage circuit: screw terminal block4; Control circuit: screw terminal block2; Current transformer: screw terminal block6; Input/output circuit: screw terminal block6; Relay output: screw terminal block4; Ethernet network: RJ45 connector
Mounting ModeFlush-mounted
Mounting SupportFramework
StandardsEN 50470-1; IEC 62053-24; IEC 60529; UL 61010-1; IEC 62053-22:2020; EN 50470-3; IEC 61557-12:2015; IEC 62053-23:2020; IEC 62052-11:2020; IEC 62052-31:2015
Product CertificationsCE conforming to IEC 61010-1; CULus conforming to UL 61010-1
Width96 mm
Depth72 mm
Height96 mm
Net Weight430 g
Environment7
Electromagnetic CompatibilityLimits for harmonic current emissions class A conforming to IEC 61000-3-2; Electrostatic discharge level 4 conforming to IEC 61000-4-2; Conducted RF disturbances level 3 conforming to IEC 61000-4-6; Magnetic field at power frequency level 4 conforming to IEC 61000-4-8; Conducted and radiated emissions class B conforming to EN 55022
IP Degree Of ProtectionIP51 display: conforming to IEC 60529; IP30 rear: conforming to IEC 60529
Relative Humidity5…95 % at 50 °C non-condensing
Pollution Degree2
Ambient Air Temperature For Operation-25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display
Ambient Air Temperature For Storage-40…85 °C
Operating Altitude<= 3000 m
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height11.500 cm
Package 1 Width12.700 cm
Package 1 Length12.700 cm
Package 1 Weight502.000 g
Unit Type Of Package 2S03
Number Of Units In Package 212
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.600 kg
Unit Type Of Package 3P06
Number Of Units In Package 396
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight62.800 kg
Logistical informations1
Country Of OriginIN
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents4

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support