Schneider
temperature control relay RM35-A - 24..240 V AC/DC - 2 NO

Not for sale
Schneider RM35ATW5MW, temperature control relay RM35-A - 24..240 V AC/DC - 2 NO. Category: Harmony Control Relays. Not for sale; no price or quote is offered for this product.
- Reference:RM35ATW5MW
- Manufacturer / Brand:Schneider
Key Specifications
- Range Of Product
- Harmony Control Relays
- Relay Type
- Temperature control relays
- Product Or Component Type
- Elevator machine room temperature control relay
- Product Specific Application
- For elevator machine rooms and 3-phase supplies
Product Description
- "This Harmony RM35-A control relay allows monitoring of temperature control."
- "This modular control relay is ideal for monitoring of electrical values and temperature variation in industrial and building control panels."
- "It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water."
- "It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device."
- "It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers."
- "It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting."
- "Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC."
Technical Specifications
Main13
| Range Of Product | Harmony Control Relays |
|---|---|
| Relay Type | Temperature control relays |
| Product Or Component Type | Elevator machine room temperature control relay |
| Product Specific Application | For elevator machine rooms and 3-phase supplies |
| Relay Name | RM35AT |
| Relay Monitored Parameters | Phase sequence; Phase failure detection; Under temperature: -1...11°C; Over temperature: 34...46°C |
| Time Delay Range | 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value) |
| Switching Capacity In VA | 1250 VA |
| Minimum Switching Current | 10 mA at 5 V DC |
| Maximum Power Consumption In VA | 3.5 VA AC |
| Utilisation Category | AC-12 conforming to IEC 60947-5-1; AC-13 conforming to IEC 60947-5-1; AC-14 conforming to IEC 60947-5-1; AC-15 conforming to IEC 60947-5-1; DC-12 conforming to IEC 60947-5-1; DC-13 conforming to IEC 60947-5-1; DC-14 conforming to IEC 60947-5-1 |
| Time Delay | Adjustable 1...10 s Tt- time delay upon fault |
| Measurement Range | 208...480 V AC; +/- 1...46 °C |
Complementary32
| Reset Time | 8 s |
|---|---|
| Maximum Switching Voltage | 250 V AC/DC |
| [Us] Rated Supply Voltage | 24...240 V AC/DC |
| [Un] Rated Nominal Voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Supply Voltage Limits | 20.4…264 V AC; 21.6…264 V DC |
| Maximum Power Consumption In W | 0.6 W DC |
| Resistance Across Terminals | 600 kOhm at 3-phase; 1.33 kOhm at temperature |
| Width | 35 mm |
| Output Contacts | 2 NO |
| Contacts Material | Cadmium free |
| Nominal Output Current | 5 A |
| Delay At Power Up | 0.2 s |
| Measurement Accuracy | +/- 2 °C |
| Response Time | <= 3.5 s + Tt (in case of temperature fault); 500 ms (in case of 3-phase fault); 500 ms (on disappearance of fault) |
| Temperature Probe Type | Pt 100 - 3-wire |
| Installed Device | Pt 100 probe cable length <= 10 m |
| Marking | CE : EMC 89/336/EEC; CE : 73/23/EEC |
| Overvoltage Category | III conforming to IEC 60664-1 |
| Insulation Resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5; > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1; > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5; > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1; > 500 MOhm at 500 V DC between measurement and relay output conforming |
| [Ui] Rated Insulation Voltage | 400 V conforming to IEC 60664-1 |
| Operating Voltage Tolerance | - 10 % + 10 % Un DC; - 15 % + 10 % Un AC |
| Supply Frequency | 50/60 Hz +/- 10 % |
| Operating Position | Any position without derating |
| Connections - Terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end; Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end; Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end; Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end |
| Tightening Torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing Material | Polycarbonate |
| Local Signalling | 1 LED green for power ON; 1 LED yellow for correct temperature (high R1)/(low R2); 1 LED yellow for phases of relay |
| Mounting Support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical Durability | 100000 cycles |
| Mechanical Durability | 30000000 cycles |
| Operating Rate | <= 360 operations/hour full load |
| Control Type | Without test button |
Environment12
| Immunity To Microbreaks | 10 ms |
|---|---|
| Electromagnetic Compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4; Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3; Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
| Standards | NF EN 60255-6; IEC 60255-6 |
| Product Certifications | GL; UL; C-Tick; CSA; GOST |
| Ambient Air Temperature For Storage | -40…70 °C |
| Ambient Air Temperature For Operation | -20…50 °C |
| Vibration Resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1; 1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
| Shock Resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP Degree Of Protection | IP20 (terminals) conforming to IEC 60529; IP30 (casing) conforming to IEC 60529 |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Dielectric Test Voltage | 2 kV, 1 min AC 50 Hz |
| Non-dissipating Shock Wave | 4 kV |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 7.8 cm |
| Package 1 Width | 4.4 cm |
| Package 1 Length | 9.7 cm |
| Package 1 Weight | 133.0 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 48 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 7.097 kg |
Logistical informations1
| Country Of Origin | ID |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.