Schneider
RUMC31BD - 3-pole changeover contact, universal relay, 24VDC
Schneider RUMC31BD, 3-pole changeover contact, universal relay, 24VDC. Category: Harmony Electromechanical Relays. Request a quote for price and lead time.
- Reference:RUMC31BD
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:20.20 EUR (Request a quote)
Key Specifications
- Range Of Product
- Harmony Electromechanical Relays
- Series Name
- RUM series
- Product Or Component Type
- Plug-in relay
- Relay Type
- Universal relay
Product Description
- "This Harmony RUM universal plug-in relay uses cylindrical pins, has a control coil voltage of 24V DC and has 3 changeover contacts triple pole double throw with a rating of 10A."
- "It provides a complete system solution for the most demanding applications."
- "It also offers one-step lockable test button."
- "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere."
- "The product is IP40 and has a transparent cover allowing operator to visually inspect the status of contacts."
- "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs)."
Key Features
- "Help to reduce the size of enclosures enabling it to be mount nearly everywhere"
- "Provides economical solution for the implementation of many switching functions with large number of contacts"
- "It is a flexible design for space-saving"
- "Plug in type allows for easy installation and maintenance"
- "Latest interface relay with single-step loackable testing function for user securey confident"
Technical Specifications
Main9
| Range Of Product | Harmony Electromechanical Relays |
|---|---|
| Series Name | RUM series |
| Product Or Component Type | Plug-in relay |
| Relay Type | Universal relay |
| Contacts Type And Composition | 3 C/O |
| Status LED | Without |
| Control Type | Lockable test button |
| [Uc] Control Circuit Voltage | 24 V DC |
| [Ithe] Conventional Enclosed Thermal Current | 10 A at -40…55 °C |
Complementary28
| [Uimp] Rated Impulse Withstand Voltage | 4 kV (1.2/50 µs) |
|---|---|
| Minimum Switching Capacity | 170 mW at 10 mA, 17 V |
| Electrical Durability | 100000 cycles for resistive load |
| Operating Time | 20 ms at nominal voltage |
| Rated Operational Voltage Limits | 19.2...26.4 V DC |
| [Ui] Rated Insulation Voltage | 250 V conforming to IEC; 300 V conforming to CSA; 300 V conforming to UL |
| Reset Time | 20 ms at nominal voltage |
| Maximum Switching Voltage | 250 V conforming to IEC |
| Drop-out Voltage Threshold | >= 0.1 Uc DC |
| [Ie] Rated Operational Current | 10 A at 277 V AC conforming to UL; 10 A at 30 V DC conforming to UL; 10 A at 277 V AC (same polarity) conforming to CSA; 10 A at 30 V DC conforming to CSA; 5 A at 250 V AC (NC) conforming to IEC; 5 A at 28 V DC (NC) conforming to IEC; 10 A at 250 V AC (NO) conforming to IEC; 10 A at 28 V DC (NO) conforming to IEC |
| Average Resistance | 470 Ohm at 20 °C +/- 15 % |
| Maximum Switching Capacity | 2500 VA/280 W |
| Mechanical Durability | 5000000 cycles |
| Safety Reliability Data | B10d = 100000 |
| Operating Rate | <= 18000 cycles/hour no-load; <= 1200 cycles/hour under load |
| Utilisation Coefficient | 20 % |
| Compatibility Code | RUM |
| Dielectric Strength | 1500 V AC between contacts with micro disconnection; 2500 V AC between coil and contact with reinforced; 2000 V AC between poles with basic |
| Protection Category | RT I |
| Pollution Degree | 2 |
| Operating Position | Any position |
| Test Levels | Level A group mounting |
| Device Presentation | Complete product |
| Contacts Material | AgNi |
| Shape Of Pin | Cylindrical |
| Net Weight | 0.086 kg |
| Average Coil Consumption | 1.4 W |
| Load Current | 10 A at 250 V AC; 10 A at 28 V DC |
Environment7
| Ambient Air Temperature For Operation | -40…55 °C |
|---|---|
| IP Degree Of Protection | IP40 |
| Standards | IEC 61810-1; CSA C22.2 No 14; UL 508 |
| Product Certifications | EAC; UL; CSA |
| Ambient Air Temperature For Storage | -40…85 °C |
| Vibration Resistance | 3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation; 4 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating |
| Shock Resistance | 10 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27; 10 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27 |
Packing Units18
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 3.500 cm |
| Package 1 Width | 6.900 cm |
| Package 1 Length | 3.600 cm |
| Package 1 Weight | 97.000 g |
| Unit Type Of Package 2 | BB1 |
| Number Of Units In Package 2 | 10 |
| Package 2 Height | 4.000 cm |
| Package 2 Width | 14.600 cm |
| Package 2 Length | 20.000 cm |
| Package 2 Weight | 1.029 kg |
| Unit Type Of Package 3 | S02 |
| Number Of Units In Package 3 | 60 |
| Package 3 Height | 15 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 6.682 kg |
Logistical informations1
| Country Of Origin | CN |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.