Schneider TWDLCAA16DRF - Compact base controller, Twido, 100 to 240VAC supply, extendable, 9 inputs with 24VDC, 7 output relays
Schneider

Compact base controller, Twido, 100 to 240VAC supply, extendable, 9 inputs with 24VDC, 7 output relays

Not for sale

Schneider TWDLCAA16DRF, Compact base controller, Twido, 100 to 240VAC supply, extendable, 9 inputs with 24VDC, 7 output relays. Category: Twido. Not for sale; no price or quote is offered for this product.

Key Specifications

Range Of Product
Twido
Product Or Component Type
Compact base controller
Discrete I/O Number
16
Discrete Input Number
9

Product Description

  • "OEM approved compact base controller"
  • "Designed for PLC Twido"
  • "One slot available for additional serial port"
  • "4 NO contacts"
  • "Includes one analog potentiometer"

Technical Specifications

Main12
Range Of ProductTwido
Product Or Component TypeCompact base controller
Discrete I/O Number16
Discrete Input Number9
Discrete Input Voltage24 V
Discrete Input Voltage TypeDC
Discrete Output Number7 for relay
[Us] Rated Supply Voltage100...240 V AC
Use Of SlotMemory cartridge or realtime clock cartridge
Data Backed UpInternal RAM lithium, 30 days autonomy, charging time: 10 h, battery life: 10 year(s)
Integrated Connection TypePower supply; Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII (RS485) half duplex, 38.4 kbit/s; Serial link interface adaptor (RS232C/RS485)
Range CompatibilityTwido
Complementary39
Discrete Input LogicSink or source
Input Voltage Limits20.4...28.8 V
Discrete Input Current11 mA for I0.0 to I0.1; 7 mA for I0.2 to I0.8
Input Impedance2100 Ohm for I0.0 to I0.1; 3400 Ohm for I0.2 to I0.8
Filter Time150 µs + programmed filter time for I0.6 to I0.8 at state 0; 35 µs + programmed filter time for I0.0 to I0.5 at state 1; 40 µs + programmed filter time for I0.6 to I0.8 at state 1; 45 µs + programmed filter time for I0.0 to I0.5 at state 0
Insulation Between Channel And Internal Logic1500 Vrms for 1 minute
Insulation Resistance Between ChannelNone
Minimum Load0.1 mA
Contact Resistance30000 µOhm
Load Current2 A at 240 V AC inductive load, operating rate <30 cyc/mn for relay output; 2 A at 240 V AC resistive load, operating rate <30 cyc/mn for relay output; 2 A at 30 V DC inductive load, operating rate <30 cyc/mn for relay output; 2 A at 30 V DC resistive load, operating rate <30 cyc/mn for relay output
Mechanical Durability20000000 cycles for relay output
Electrical Durability100000 cycles for relay output
Current Consumption30 mA at 5 V DC at state 1; 40 mA at 24 V DC at state 1; 5 mA at 5 V DC at state 0
I/O ConnectionNon-removable screw terminal block
Network Frequency50/60 Hz
Supply Voltage Limits85…264 V
Network Frequency Limits47…63 Hz
Power Supply Output Current0.25 A for 24 V DC sensors
Input Current300 mA
Inrush Current35 A
Protection TypePower protection by internal fuse
Power Consumption In VA22 VA at 100 V; 31 VA at 264 V
Insulation Resistance> 10 MOhm at 500 V, between I/O and earth terminals; > 10 MOhm at 500 V, between supply and earth terminals
Program Memory2000 instructions
Exact Time For 1 Kinstruction1 ms
System Overhead0.5 ms
Memory DescriptionInternal RAM, 128 counters, no floating, no trigonometrical; Internal RAM, 128 internal bits, no floating, no trigonometrical; Internal RAM, 3000 internal words, no floating, no trigonometrical; Internal RAM, 64 timers, no floating, no trigonometrical; Internal RAM, double words, no floating, no trigonometrical
Free Slots1
Realtime ClockWithout clock
Counting Input Number1 counting input(s) at 20000 Hz 32 bits; 3 counting input(s) at 5000 Hz 16 bits
Analogue Adjustment Points1 point adjustable from 0...1023
Status LED1 LED (green) PWR; 1 LED (green) RUN; 1 LED per channel (green) I/O status; 1 LED (red) module error (ERR); 1 LED user pilot light (STAT)
Depth70 mm
Height80 mm
Width90 mm
Terminals Description PLC N°1(1)IN_DIS#1; ALT; (3)IN_DIS#3; (-)PW_OUT_NEG; (5)IN_DIS#5; (+)PW_OUT_POS; TB_TOP; (0)IN_DIS#0; (4)IN_DIS#4; COM_NEG#0-8; (2)IN_DIS#2; (8)IN_DIS#8; (6)IN_DIS#6; (7)IN_DIS#7
Terminals Description PLC N°2(7)IN_DIS#7; TB_TOP; (-)PW_OUT_NEG; (5)IN_DIS#5; (3)IN_DIS#3; (1)IN_DIS#1; (+)PW_OUT_POS; (6)IN_DIS#6; (2)IN_DIS#2; (0)IN_DIS#0; ALT_1; (8)IN_DIS#8; (4)IN_DIS#4; COM_POS#0-8
Terminals Description PLC N°3(COM1)COM#4-5; (6)OUT_DIS#6; (-)PW_NEG; (0)OUT_DIS#0; (+)PW_POS; (1)OUT_DIS#1; (COM0)COM#0-3; (COM2)COM#6; (5)OUT_DIS#5; (2)OUT_DIS#2; (3)OUT_DIS#3; TB_BOTTOM; (4)OUT_DIS#4; (GND)GROUND
Net Weight0.25 kg
Environment12
Immunity To Microbreaks10 ms
Dielectric Strength1500 V for 1 minute, between I/O and earth terminals; 1500 V for 1 minute, between supply and earth terminals
Product CertificationsUL; CSA
MarkingCE
Ambient Air Temperature For Operation0…55 °C
Ambient Air Temperature For Storage-25…70 °C
Relative Humidity30…95 % without condensation
IP Degree Of ProtectionIP20
Operating Altitude0...2000 m
Storage Altitude0…3000 m
Vibration Resistance0.075 mm at 10…57 Hz on 35 mm symmetrical DIN rail; 1 gn at 57…150 Hz on 35 mm symmetrical DIN rail; 1.6 mm at 2…25 Hz on plate or panel with fixing kit; 4 gn at 25…100 Hz on plate or panel with fixing kit
Shock Resistance15 gn for 11 ms
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height10.5 cm
Package 1 Width11.0 cm
Package 1 Length12.5 cm
Package 1 Weight375.0 g
Unit Type Of Package 2S03
Number Of Units In Package 212
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.03 kg
Unit Type Of Package 3S01
Number Of Units In Package 33
Package 3 Height15.0 cm
Package 3 Width15.0 cm
Package 3 Length40.0 cm
Package 3 Weight1.254 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads