XPSBAC14AP - Cat.4, Pl e, SIL3, E-stop and guard switch, 4NA, 48-240V AC
Schneider XPSBAC14AP, Cat.4, Pl e, SIL3, E-stop and guard switch, 4NA, 48-240V AC. Category: Harmony XPS. Request a quote for price and lead time.
- Reference:XPSBAC14AP
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:245.00 EUR (Request a quote)
Key Specifications
- Range Of Product
- Harmony Safety Automation
- Product Or Component Type
- Safety module
- Safety Module Name
- XPSBAC
- Electrical Circuit Type
- NC pair
Product Description
This safety relay is designed for monitoring Emergency stop and Guard switch. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This basic safety modules embeds pre-defined safety functions. This safety relay embeds 1 control output, 4 NO safety outputs, and 2 NC diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO13849-1, SILCL 3 conforming to IEC62061, SIL 3 conforming to IEC61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.
Key Features
- "Designed for monitoring Emergency stop and Guard switch"
- "PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508"
- "Screw removable terminal blocks on 2 rows on both top and bottom sides"
- "Implement safety functions"
- "Reduce risk to an acceptable level"
Technical Specifications
Main10
| Range Of Product | Harmony Safety Automation |
|---|---|
| Product Or Component Type | Safety module |
| Safety Module Name | XPSBAC |
| Safety Module Application | For emergency stop and protective guard applications |
| Function Of Module | Emergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches |
| Safety Level | Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1; Can reach SILCL 3 for normally open relay contact conforming to IEC 62061; Can reach SIL 3 for normally open relay contact conforming to IEC 61508; Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1; Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061; Can |
| Safety Reliability Data | MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contact; Dcavg >= 99 % conforming to ISO 13849-1 for normally open relay contact; PFHd = 0.95E-09 conforming to ISO 13849-1 for normally open relay contact; HFT = 1 conforming to IEC 62061 for normally open relay contact; PFHd = 0.95E-09 conforming to IEC 62061 for normally open relay contact; SFF > 99% conforming to IEC 62061 for |
| Electrical Circuit Type | NC pair |
| Connections - Terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with fe |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 %; 24 V DC - 20...20 % |
Complementary24
| Synchronisation Time Between Inputs | Unlimited |
|---|---|
| Type Of Start | Automatic/manual/monitored |
| Power Consumption In W | 1.5 W 24 V DC |
| Power Consumption In VA | 3.5 VA 24 V AC 50/60 Hz |
| Input Protection Type | Internal, electronic |
| Safety Outputs | 4 NO + 1 NC |
| Safety Inputs | 0 |
| Input Compatibility | Normally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850 |
| Input Terminal | Power supply |
| [Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact |
| Control Outputs | 0 |
| [Ith] Conventional Free Air Thermal Current | 6 A |
| Associated Fuse Rating | 10 A gG for NO relay output circuit conforming to IEC 60947-1 |
| Minimum Output Current | 10 mA for relay output |
| Minimum Output Voltage | 5 V for relay output |
| Response Time | 150 ms at 24 V AC; 80 ms at 24 V DC |
| [Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to IEC 60947-1 |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category II conforming to IEC 60947-1 |
| Local Signalling | LED green with power marking for power ON; LED red with error marking for error; LED yellow with state marking for status; LED yellow with start1 marking for start input; LED yellow with start2 marking for start input |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 120 mm |
| Height | 100 mm |
| Width | 22.5 mm |
| Net Weight | 0.200 kg |
Environment5
| Ambient Air Temperature For Operation | -25…55 °C |
|---|---|
| Standards | IEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard |
| Product Certifications | TÜV; cULus |
| IP Degree Of Protection | IP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529 |
| Relative Humidity | 5…95 % non-condensing |
Packing Units18
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 6.500 cm |
| Package 1 Width | 13.500 cm |
| Package 1 Length | 15.500 cm |
| Package 1 Weight | 298.000 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 16 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.482 kg |
| Unit Type Of Package 3 | P06 |
| Number Of Units In Package 3 | 128 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 49.000 kg |
Logistical informations1
| Country Of Origin | ID |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads
Documents are published by the manufacturer and open in a new tab.