Schneider XPSUS12AP - E-stop, light curtain, two-hand control, edge detection, 2 safety inputs, 2NA, 24V AC/DC
Schneider

XPSUS12AP - E-stop, light curtain, two-hand control, edge detection, 2 safety inputs, 2NA, 24V AC/DC

Schneider XPSUS12AP, E-stop, light curtain, two-hand control, edge detection, 2 safety inputs, 2NA, 24V AC/DC. Category: Harmony XPS. Request a quote for price and lead time.

Key Specifications

Range Of Product
Harmony Safety Automation
Product Or Component Type
Safety module
Safety Module Name
XPSUS
Electrical Circuit Type
NC pair; PNP pair; Antivalent pair; OSSD pair

Product Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch, Safety light curtain, Two hand control station or Enabling switch. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 2 NO safety outputs, and 1 solid-state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.

Key Features

  • "More than 40 different diagnostic messages, without additional fieldbus interface"
  • "Reduced down time of the machine due to messages"
  • "Status information about upcoming test intervals and amount of remaining cycles before reaching end of life time"
  • "ECODESIGN: Optimized Energy Efficiency: Reduction of 24 per cent of CO2 on the whole product life cycle"
  • "Reduce risk to an acceptable level"

Technical Specifications

Main10
Range Of ProductHarmony Safety Automation
Product Or Component TypeSafety module
Safety Module NameXPSUS
Safety Module ApplicationFor electrical monitoring of two-hand control stations; Monitoring antivalent contacts; For emergency stop, guard and light curtain monitoring; For enabling switch monitoring
Function Of ModuleEmergency stop button with 2 NC contacts; Guard monitoring with 1 or 2 limit switches; Monitoring 2 PNP sensors; Magnetic switch monitoring; Light curtain monitoring; RFID switch; Monitoring of electro-sensitive protection equipment (ESPE); Enabling switch monitoring; Proximity sensor monitoring; Monitoring two-hand control station
Safety LevelCan reach PL e/category 4 conforming to ISO 13849-1; Can reach SILCL 3 conforming to IEC 62061; Can reach SIL 3 conforming to IEC 61508
Safety Reliability DataMTTFd > 30 years conforming to ISO 13849-1; Dcavg >= 99 % conforming to ISO 13849-1; PFHd = 1.13E-09 conforming to ISO 13849-1; HFT = 1 conforming to IEC 62061; PFHd = 1.13E-09 conforming to IEC 62061; SFF > 99% conforming to IEC 62061; HFT = 1 conforming to IEC 61508-1; PFHd = 1.13E-09 conforming to IEC 61508-1; SFF > 99% conforming to IEC 61508-1; Type = B conforming to IEC 61508-1
Electrical Circuit TypeNC pair; PNP pair; Antivalent pair; OSSD pair
Connections - TerminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexible; Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor; Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor; Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel; Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with fe
[Us] Rated Supply Voltage24 V AC - 15...10 %; 24 V DC - 20...20 %
Complementary25
Synchronisation Time Between Inputs0.5 s; 2 s; 4 s
Type Of StartAutomatic/manual/monitored
Power Consumption In W2 W 24 V DC
Power Consumption In VA5.0 VA 24 V AC 50/60 Hz
Input Protection TypeInternal, electronic
Safety Outputs2 NO
Safety Inputs2 safety input 24 V DC 5 mA
Maximum Wire Resistance500 Ohm
Input CompatibilityNormally closed circuit conforming to ISO 14119; XC limit switch conforming to ISO 14119; Mechanical contact conforming to ISO 14119; Normally closed circuit conforming to ISO 13850; Antivalent pair conforming to ISO 14119; OSSD pair conforming to IEC 61496-1-2; Two-hand control conforming to EN 574/ISO 13851-III A; Two-hand control conforming to EN 574/ISO 13851-III C; 3-wire proximity sensors PN
[Ie] Rated Operational Current5 A AC-1 for normally open relay contact; 3 A AC-15 for normally open relay contact; 5 A DC-1 for normally open relay contact; 3 A DC-13 for normally open relay contact; 3 A AC-1 for normally closed relay contact; 1 A AC-15 for normally closed relay contact; 3 A DC-1 for normally closed relay contact; 1 A DC-13 for normally closed relay contact
Control Outputs3 on/off configurable pulsed output
Input/output TypeSemiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Ith] Conventional Free Air Thermal Current8 A
Associated Fuse Rating10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum Output Current10 mA for relay output
Minimum Output Voltage12 V for relay output
Maximum Response Time On Input Open20 ms
[Ui] Rated Insulation Voltage250 V (pollution degree 2) conforming to IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category II conforming to IEC 60947-1
Local SignallingLED (green) for power ON; LED (red) for error; LED (yellow) for safety output status; LED (yellow) for start input; LED (yellow) for safety input S12; LED (yellow) for safety input S13; LED (yellow) for safety input S22; LED (yellow) for safety input S23
Mounting Support35 mm symmetrical DIN rail
Depth120 mm
Height100 mm
Width22.5 mm
Net Weight0.200 kg
Environment5
StandardsIEC 60947-5-1; IEC 61508-1 functional safety standard; IEC 61508-2 functional safety standard; IEC 61508-3 functional safety standard; IEC 61508-4 functional safety standard; IEC 61508-5 functional safety standard; IEC 61508-6 functional safety standard; IEC 61508-7 functional safety standard; ISO 13849-1 functional safety standard; IEC 62061 functional safety standard
Product CertificationsTÜV; cULus
IP Degree Of ProtectionIP20 (terminals) conforming to IEC 60529; IP40 (housing) conforming to IEC 60529; IP54 (mounting area) conforming to IEC 60529
Ambient Air Temperature For Storage-25…85 °C
Relative Humidity5…95 % non-condensing
Packing Units18
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height6.500 cm
Package 1 Width13.500 cm
Package 1 Length16.000 cm
Package 1 Weight279.000 g
Unit Type Of Package 2S03
Number Of Units In Package 216
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.133 kg
Unit Type Of Package 3P06
Number Of Units In Package 3128
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight47.500 kg
Logistical informations1
Country Of OriginID
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents4

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support