Telemecanique Sensors XY2CEDA290 - INTERRUPTEUR À CÂBLE D'ARRÊT D'URGENCE
Telemecanique Sensors

XY2CEDA290 - INTERRUPTEUR À CÂBLE D'ARRÊT D'URGENCE

Telemecanique Sensors XY2CEDA290, INTERRUPTEUR À CÂBLE D'ARRÊT D'URGENCE. Catégorie : Standard size - up to 70 m. Demandez un devis pour le prix et le délai.

Caractéristiques clés

Type De Produit Ou De Composant
Dual emergency stop rope pull switch
Nom Court De L'appareil
XY2CED
Couleur Du Boîtier
Red RAL 3000
Catégorie De Surtension
Class I conforming to IEC 61140

Description du produit

Telemecanique Sensors XY2CEDA290 (TRIP WIRE SWITCH). Ask UC-EL Electric for a quote with the current price, stock and delivery details.

Caractéristiques techniques

Gamme De ProduitsTelemecanique Emergency stop rope pull switches XY2C
Type De Produit Ou De ComposantDual emergency stop rope pull switch
Nom Court De L'appareilXY2CED
Couleur Du BoîtierRed RAL 3000
Catégorie De SurtensionClass I conforming to IEC 61140
Signalisation LocaleWithout pilot light
Matière Du SouffletNitril
Matière Du CorpsZamak
Matière Du CouvercleStainless steel
RéarmementBy booted push-button
Type Et Composition Des Contacts2 x (1 NC + 1 NO)
Fonctionnement Des ContactsSlow-break
Point D'ancrage Du Câble De DéclenchementRH and LH sides
Connexions - BornesScrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
Niveau De SécuritéCan reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Données De Fiabilité De SécuritéB10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
MarquageCE
Ouverture PositiveWith conforming to IEC 60947-5-1
Résistance Entre Les Bornes25 MOhm conforming to IEC 60255-7 category 3
Description Des Bornes ISO N°1(13-14)NO, (21-22)NC
Code De CompatibilitéXY2CED
NormesCSA C22.2 No 14, IEC 60204-1, IEC 60947-5-1, IEC 60947-5-5, ISO 13850, machinery directive 2006/42/EC, UL 508, work equipment directive 2009/104/EC
Certifications Du ProduitUL category NISD emergency stop devices, CSA, CCC, EAC
Traitement De ProtectionTC
Tenue Aux Vibrations10 gn (f= 10-300 Hz) conforming to IEC 60068-2-6
Tenue Aux Chocs50 gn 11 ms conforming to IEC 60068-2-27
Degré De Protection IPIP66 conforming to IEC 60529
Proposition 65 De CalifornieWARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Type D'unité De Paquet 1piece
Nombre D'unités Dans Le Paquet 11
Hauteur Du Paquet 110.6 cm
Largeur Du Paquet 116 cm
Longueur Du Paquet 130.8 cm
Poids Du Paquet 11.96 kg
Type D'unité De Paquet 2S03
Nombre D'unités Dans Le Paquet 24
Hauteur Du Paquet 230 cm
Largeur Du Paquet 230 cm
Longueur Du Paquet 240 cm
Poids Du Paquet 28.405 kg
Quantité De Vente Indivisible1

Documents et téléchargements

Les documents sont publiés par le fabricant et s'ouvrent dans un nouvel onglet.