Telemecanique Sensors XY2CJS15 - TRIP WIRE SWITCH
Telemecanique Sensors

XY2CJS15 - TRIP WIRE SWITCH

Telemecanique Sensors XY2CJS15, TRIP WIRE SWITCH. Fiyat ve teslim süresi için teklif isteyin.

Öne Çıkan Özellikler

Ürün Ya Da Bileşen Tipi
Latching emergency stop rope pull switch
Cihaz Kısa Adı
XY2C
Gövde Rengi
Red RAL 3000
Aşırı Gerilim Kategorisi
Class I conforming to IEC 61140

Ürün Açıklaması

XY2CJS15 - ÇEKME TELSİZ ŞALTER

Teknik Özellikler

Ürün SerisiTelemecanique Emergency stop rope pull switches XY2C
Ürün Ya Da Bileşen TipiLatching emergency stop rope pull switch
Cihaz Kısa AdıXY2C
Gövde RengiRed RAL 3000
Aşırı Gerilim KategorisiClass I conforming to IEC 61140
Yerel SinyallemeColor indicator
Gövde MalzemesiZamak
Kafa MalzemesiPA (polyamide)
Kapak MalzemesiGalvanised steel
SıfırlamaBy pull button
Kontak Tipi Ve Kompozisyonu1 NC + 1 NO
Kontak OperasyonuSlow-break
Tetik Kablosu Ankraj NoktasıRH or LH side
Bağlantılar - TerminallerScrew clamp terminal, 1 x 0.5...2 x 1.5 mm²
Güvenlik SeviyesiCan reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Güvenlik Güvenilirlik VerileriB10d = 500000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
İşaretlemeCE
Pozitif AçılmaWith conforming to IEC 60947-5-1
Terminaller Arası Direnç25 MOhm conforming to IEC 60255-7 category 3, 25 MOhm conforming to NF C 93-050 method A
Terminallerin Tanımı ISO No. 1(13-14)NO, (21-22)NC
Uyumluluk KoduXY2CJ
StandartlarCSA C22.2 No 14, IEC 60204-1, IEC 60947-5-1, IEC 60947-5-5, ISO 13850, machinery directive 2006/42/EC, UL 508, work equipment directive 2009/104/EC
Ürün SertifikalarıUL category NISD emergency stop devices, CSA, CCC, EAC
Koruyucu İşlemTC
Titreşim Direnci10 gn (f= 10-150 Hz) conforming to IEC 60068-2-6
Şok Direnci50 gn 11 ms conforming to IEC 60068-2-27
IP Koruma DerecesiIP66 conforming to IEC 60529, IP67 conforming to IEC 60529
Kaliforniya Önerisi 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Paket 1 Birim Türüpiece
Paket 1 Birim Sayısı1
Paket 1 Yüksekliği7.3 cm
Paket 1 Genişliği24.6 cm
Paket 1 Uzunluğu5.6 cm
Paket 1 Ağırlığı0.52 kg
Paket 2 Birim TürüS02
Paket 2 Birim Sayısı10
Paket 2 Yüksekliği30 cm
Paket 2 Genişliği15 cm
Paket 2 Uzunluğu40 cm
Paket 2 Ağırlığı5.655 kg
Paket 3 Birim Türücarton
Paket 3 Birim Sayısı1
Paket 3 Yüksekliği5.6 cm
Paket 3 Genişliği7.3 cm
Paket 3 Uzunluğu24.6 cm
Paket 3 Ağırlığı0.52 kg
Bölünemez Satış Miktarı1

Dokümanlar ve İndirmeler

Dokümanlar üreticinin sitesinde yayınlanır ve yeni sekmede açılır.

Veri Sayfaları1
Kataloglar2
Broşürler3
Kullanım Talimatları6
Çevre Bilgileri3
Uygunluk Beyanları2
CAD Çizimleri3
Diğer Dokümanlar2

Etiketler

Aynı etikete sahip ürünleri katalogda görün.

WhatsApp İletişim Hattı