56163 - RH21M 220/240 V AC 50/60/400 Hz WITH MANUAL FAULT RESET
Schneider 56163, RH21M 220/240 V AC 50/60/400 Hz WITH MANUAL FAULT RESET. Category: Vigirex RH10MP-RH21MP-RH99MP-RH197-RHU. Request a quote for price and lead time.
- Reference:56163
- Manufacturer / Brand:Schneider
- Availability:On Request / Inquire Stock
- Price:362.00 EUR (Request a quote)
Key Specifications
- Range
- VigiPacT
- Device Short Name
- RH21M
- Product Or Component Type
- Residual current protection relay
- Relay Application
- Protection relay
Product Description
VigiPacT RH21M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 220/240VAC 50/60Hz. The current sensitivity is selectable with 2 thresholds 30 mA and 300 mA. The time delay is instantaneous 0.06s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.
Key Features
- "VigiPacT relays ensure coordination with ComPacT circuit breakers (switch off within 40ms)"
- "Continuous monitoring of the power supply, the relay/toroid link and internal electronics"
- "Reinforced insulation of VigiPacT relays (overvoltage category IV)"
- "Access to settings protected by a lead-sealable cover or password"
- RoHS and REACH compliant
Technical Specifications
Main19
| Range | VigiPacT |
|---|---|
| Device Short Name | RH21M |
| Product Or Component Type | Residual current protection relay |
| Relay Application | Protection relay |
| Mounting Support | DIN rail |
| Earth-leakage Protection Class | Type A |
| Type Of Setting | Selector |
| Residual Earth-leakage Sensitity Adjustment Type | Adjustable 2 settings |
| Earth-leakage Sensitivity | 0.03 A; 0.3 A |
| Earth-leakage Time Delay | Instantaneous for 0.03 A; Instantaneous for 0.3 A; Fixed 0.06 s for 0.3 A |
| Current Sensors Compatibility | VigiPacT TOA earth leakage current sensor; VigiPacT A earth leakage current sensor; VigiPacT L earth leakage current sensor |
| [Ithe] Conventional Enclosed Thermal Current | 8 A |
| Minimum Load | 10 mA at 12 V |
| [Us] Rated Supply Voltage | 220...240 V AC 50/60 Hz 55...110 % |
| Power Consumption In VA | 4 VA |
| Monitored Distribution System | 1000 V - AC at 50/60 Hz (maximum); 1000 V - AC at 400 Hz (maximum) |
| Earthing System | IT; TT; TN-S |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Reset | Manual reset |
Complementary16
| Test Function | Local; Remote test |
|---|---|
| Monitoring | Electronics (continuous); Power supply (continuous); Relay/sensor link (continuous) |
| Type Of Measurement | Earth fault current internal measurement, range: 80...100 % |
| Tamperproof Of Settings | Protected by sealable cover |
| Connections - Terminals | Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible 24 AWG...12 AWG; Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid 24 AWG...12 AWG; Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible 24 AWG...12 AWG; Fault: screw terminal cable(s) 0.2…2.5 mm² flexible 24 AWG...12 AWG; Fault: screw terminal cable(s) 0.2…4 mm² rigid 24 AWG...12 AWG; Fault: scre |
| Wire Stripping Length | Auxiliary power supply: 7 mm for top connection; Fault: 8 mm for bottom connection; Relay test and fault reset: 5 mm for bottom connection; Sensor: 5 mm for top connection; Voltage presence: 8 mm for bottom connection |
| Tightening Torque | Auxiliary power supply: 0.6 N.m top; Fault: 0.6 N.m bottom; Relay test and fault reset: 0.25 N.m bottom; Sensor: 0.25 N.m top; Voltage presence: 0.6 N.m bottom |
| 9 Mm Pitches | 6 |
| Standards | EN/IEC 60947-2 Annex M; EN/IEC 60755; UL 1053; CAN/CSA C22.2 No. 144 |
| Width | 54 mm |
| Height | 81 mm |
| Depth | 74 mm |
| Net Weight | 0.3 kg |
| IP Degree Of Protection | IP40 on front face: conforming to EN/IEC 60529; IP30 on side parts: conforming to EN/IEC 60529; IP20 on connection terminals: conforming to EN/IEC 60529 |
| IK Degree Of Protection | IK07 conforming to EN 50102 |
| Mechanical Robustness | Fire resistance conforming to IEC 60695-2-1; IK protection 2 joules: IK07 conforming to EN 50102; Vibrations 13.2...100 Hz: 0.7 g; Vibrations 2...13.2 Hz: +/- 1 mm |
Environment7
| Overvoltage Category | IV |
|---|---|
| Electrical Shock Protection Class | Class II |
| Electromagnetic Compatibility | Conducted and radiated emissions: , B, conforming to CISPR 11; Conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6; Electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2; High-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5; Low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4; Radiated susceptibility: , 3, conforming to IE |
| Relative Humidity | 95 % at 55 °C |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Ambient Air Temperature For Operation | -35…70 °C |
| Ambient Air Temperature For Storage | -55…85 °C |
Packing Units12
| Unit Type Of Package 1 | PCE |
|---|---|
| Number Of Units In Package 1 | 1 |
| Package 1 Height | 8.8 cm |
| Package 1 Width | 7.8 cm |
| Package 1 Length | 9.3 cm |
| Package 1 Weight | 311.0 g |
| Unit Type Of Package 2 | S03 |
| Number Of Units In Package 2 | 36 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.683 kg |
Logistical informations1
| Country Of Origin | FR |
|---|
Contractual warranty1
| Warranty (in Months) | 18 |
|---|
Documents and Downloads