Key Specifications

Device Application
Control; Distribution
Range
Acti9
Product Name
Reflex iC60
Device Short Name
Reflex iC60H

Product Description

This Acti9 Reflex iC60H is a low voltage integrated control circuit breaker. It combines integrated circuit breaker protection and load control for lighting control applications. It has 4P with 4 protected poles, rated current 10A and C tripping curve. Y1/Y2 inputs remote control voltage is 230VAC and 1A. They allow local and remote control of lighting. Y3 input remote control voltage is 24VDC and 5.5mA. Y3 allow easy connection to a Power Logic Controller or a Building Management System. Breaking capacity at 230VAC is 30kA according to IEC 60947-2 . Breaking capacity at 400VAC is 15kA according to IEC 60974-2. Electrical endurance goes up to 30000 cycles for AC-1 or AC-7a. Electrical endurance goes up to 6000 cycles for AC-5a or AC-5b and AC-7c. It is possible to associate a vigi block to have a differential protection. • Suitability for isolation according to IEC/EN 60947-2 standard

Key Features

  • Combines protection against short-circuit and overload currents
  • Easy to install with unified terminal design and wiring indication
  • Green strip ensuring physical contact opening, allowing safe downstream operations
  • Remote control via latched or impulse-type commands with three user-selectable operating modes

Technical Specifications

Main10
Device ApplicationControl; Distribution
RangeActi9
Product NameReflex iC60
Device Short NameReflex iC60H
Product Or Component TypeIntegrated control circuit breaker
Poles Description4P
Number Of Protected Poles4
Network TypeAC
Trip Unit TechnologyThermal-magnetic
Curve CodeC
Complementary24
[In] Rated Current10 A
Network Frequency50/60 Hz
Breaking Capacity CodeH
Breaking Capacity30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2; 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] Rated Insulation Voltage500 V AC
Contact Position IndicatorYes
Control TypeRemote control by pulse; Remote control by continuous command; ON/OFF button; Toggle
Control Signal TypeMaintained very low voltage; Impulse; Maintained
Local SignallingGreen LED: device ON; Red LED: fault; Flashing LED: device tripped; Flashing LED: device ready; Flashing LED: device overheat
[Uc] Control Circuit Voltage230 V AC 50/60 Hz; 24 V AC 50/60 Hz; 48 V AC 50/60 Hz; 24 V DC; 48 V DC
[Us] Rated Supply Voltage230 V AC at 50/60 Hz
Mounting ModeFixed
Mounting Support35 mm symmetrical DIN rail
9 Mm Pitches13
Height84 mm
Width117 mm
Depth77 mm
ColourWhite
Mechanical Durability50000 cycles
Electrical DurabilityAC-1: 50000 cycles AC 50 Hz
Provision For PadlockingPadlockable
Locking Options DescriptionPadlock in OFF position
Earth-leakage ProtectionSeparate block
Product CompatibilityWith PLC
Environment4
IP Degree Of ProtectionIP20 conforming to IEC 60529
Pollution Degree3
Tropicalisation2
Relative Humidity93 % at 40 °C
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height9.1 cm
Package 1 Width11.2 cm
Package 1 Length16.5 cm
Package 1 Weight796 g
Unit Type Of Package 2S03
Number Of Units In Package 214
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.631 kg
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.