| Application Specific I/O | Pulse totalising counter; Pulse converter |
|---|
| Protection Type | Short-circuit protection for analogue input; Against reverse polarity for auxiliary supply; Against reverse polarity for input; Overvoltage at 33 V DC for digital output |
|---|
| Immunity To Microbreaks | 10 ms |
|---|
| Reset | Factory reset on front face |
|---|
| Input/output Type | 2 inputs + 1 output per digital channel; 2 inputs per analog channel |
|---|
| Input Type | Current for analog input, 4...20 mA; Voltage for analog input, 0...10 V DC; Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA |
|---|
| Maximum Permanent Current | 0.005 A for digital input |
|---|
| Absolute Accuracy Error | +/- 1 % of full scale for analog input 12 bits |
|---|
| Electronic Filtering Time | 2 ms for digital input from state 0 to state 1; 2 ms for analog input from state 0 to state 1 |
|---|
| Output Type | Logic current source: 24 V - DC - 100 mA |
|---|
| Maximum Voltage Drop | <1 V at state 1 digital output |
|---|
| Inrush Current | 0.5 A for digital output; 3 A for power supply |
|---|
| Local Signalling | Communication: 1 LED (yellow); NS (Network Status): 1 LED (green, orange and red); Communication (LK/ACT 10/100): 1 LED (green and yellow); Status: 1 LED (green, orange and red) |
|---|
| Type Of Setting | Modbus address 01...247 for address encoders |
|---|
| Mounting Position | Horizontal and vertical on DIN rail |
|---|
| Colour | White (RAL 9003) |
|---|
| Location Of Connection | Front |
|---|
| Connections - Terminals | Spring-loaded terminal Ti24 qty: 7 for digital input/output, ordered separately; RJ45 connector qty: 1 for ETHERNET, ordered separately; Plug-in connector qty: 1 for supply circuit; Plug-in connector qty: 1 for communication bus; Plug-in connector qty: 1 for analog input |
|---|
| Clamping Connection Capacity | 2 x 0.25 mm² for twisted shielded pairs cable, flexible with cable end for communication bus; 2 x 0.25 mm² for twisted shielded pairs cable, flexible without cable end for communication bus; 2 x 0.25 mm² for twisted shielded pairs cable, rigid with cable end for communication bus; 2 x 0.25 mm² for twisted shielded pairs cable, rigid without cable end for communication bus; 2 x 0.25...2 x 1.5 mm² f |
|---|
| Wire Stripping Length | Control: 10 mm; Supply circuit: 7 mm; Analog input: 7 mm; Communication bus: 7 mm |
|---|
| Communication Network Type | RS485 Modbus RTU master SUB-D 9 9.6...19.2 kbauds; Ethernet Modbus TCP/IP server RJ45 10/100 Mbit/s |
|---|
| 9 Mm Pitches | 0 useful |
|---|
| Height | 22.5 mm |
|---|
| Width | 359 mm |
|---|
| Depth | 42 mm |
|---|
| Net Weight | 180 g |
|---|
| Provided Equipment | Set of 1 connector; Set of 1 bus connector; Set of 1 power supply connector; Set of 2 locking clips |
|---|
| Range Compatibility | Acti 9 iTL auxiliary; Acti 9 RCA iC60 Ti24 connector; Linergy Linergy FM; Acti 9 iOF+SD 24; Acti 9 iACT24; Acti 9 iATL24; PowerLogic pulse output meter; PowerLogic Modbus meter; Acti 9 Acti9 iCT auxiliary; Acti 9 Acti9 iC60; Acti 9 Acti9 iID; Acti 9 Acti9 iSW-NA; Acti 9 Acti9 iDPN Vigi; Acti 9 Acti9 C40; Multi9 Multi9 C60; Acti 9 Acti9 DT40; Acti 9 Acti9 DT60; Acti 9 Acti9 I-NA; Acti 9 Acti9 ITG40 |
|---|
| Commissioning Interface | Acti 9 Smart test; Web page |
|---|
| Compatibility Code | Acti 9 Smartlink IP |
|---|