Schneider A9XMSB11 - Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485
Schneider

Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485

Schneider A9XMSB11, Communication Module. EcoStruxure I/O Smart Link, Modbus, RS485. Category: Acti9 Smartlink. Request a quote for price and lead time.

Key Specifications

Range Of Product
Acti9
Range Of Product
EcoStruxure
Product Or Component Type
Smart communication module
Product Name
EcoStruxure I/O Smart Link

Product Description

This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.

Key Features

  • Transmission of data collected by switchgear assemblies
  • Load monitoring
  • Alarm management on level thresholds
  • reduce footprint and ease wiring

Technical Specifications

Main13
Range Of ProductActi9
Range Of ProductEcoStruxure
Product Or Component TypeSmart communication module
Product NameEcoStruxure I/O Smart Link
Device Short NameI/O Smart Link
Application TypeLoad control; Breaker status monitoring; Basic energy metering E
Number Max Of Connected DevicesUp to 11 wired devices
Group Of Channels1 group of 11 digital channels
Maximum Supply Current1.5 A
[Us] Rated Supply Voltage24 V DC +/- 20 %
Connectivity To DevicesDigital input and output; Pulse output meter
Communication ServiceModbus server for RS485
Web ServerBMS controller compatible
Complementary30
Application Specific I/OPulse totalising counter; Pulse converter
Protection TypeAgainst reverse polarity for auxiliary supply; Against reverse polarity for input; Overvoltage at 33 V DC for digital output
Immunity To Microbreaks10 ms
ResetFactory reset on front face; By booted push-button; By address encoder; By plug in, plug out the power supply
Input/output Type2 inputs + 1 output per digital channel
Input TypeCurrent sink for digital input, 24 V DC +/- 20 % at 2.5 mA
Maximum Permanent Current5 mA for digital input
Electronic Filtering Time2 ms for digital input from state 0 to state 1
Output TypeLogic current source: 24 V - DC - 100 mA
Maximum Voltage Drop<1 V at state 1 digital output
Inrush Current0.5 A for digital output; 7 A for power supply
Local SignallingCommunication: 1 LED (yellow); Status: 1 LED (green, orange and red)
Type Of SettingModbus address 01...99 for address encoders; Reset for address encoders; Reset for plug in, plug out the auxiliary supply
Mounting PositionHorizontal and vertical on DIN rail
ColourWhite (RAL 9003)
Location Of ConnectionFront
Connections - TerminalsSpring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately; Plug-in connector qty: 1 for supply circuit; Plug-in connector qty: 1 for communication bus
Clamping Connection Capacity2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus; 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communi
Wire Stripping LengthControl: 10 mm; Supply circuit: 7 mm; Communication bus: 7 mm
Communication Network TypeRS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
9 Mm Pitches0 useful
Height22.5 mm
Width359 mm
Depth42 mm
Net Weight188 g
Provided EquipmentSet of 1 bus connector; Set of 1 power supply connector; Set of 2 locking clips
Range CompatibilityActi 9 iTL auxiliary; Linergy Linergy FM; Acti 9 iOF+SD 24; Acti 9 iACT24; Acti 9 iATL24; PowerLogic pulse output meter; Acti 9 RCA iC60; Acti 9 Acti9 iCT auxiliary; Acti 9 Acti9 iC60; Acti 9 Acti9 iID; Acti 9 Acti9 iSW-NA; Acti 9 Acti9 iDPN Vigi; Acti 9 Acti9 C40; Multi9 Multi9 C60; Acti 9 Acti9 DT40; Acti 9 Acti9 DT60; Acti 9 Acti9 I-NA; Acti 9 Acti9 ITG40; Acti 9 Acti9 iDPN; Acti 9 Acti9 Reflex
Commissioning InterfaceEcoStruxure Power Commission
Market SegmentBuildings; Small commercial
Compatibility CodeActi 9 Smartlink
Environment14
IP Degree Of ProtectionIP20
IK Degree Of ProtectionIK06 conforming to IEC 62262
Pollution Degree3
Electromagnetic CompatibilityResistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2; Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2; Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3; Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m,
Environmental CharacteristicCorrosive 3C2 conforming to IEC 60721-3-3; Salt mist 2 conforming to IEC 60068-2-52
Vibration Resistance1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6
Shock Resistance15 gn for 11 ms conforming to IEC 60068-2-27
Fire ResistanceOther parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10; On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10
Tropicalisation2
Relative Humidity0…93 % at 40 °C
Operating Altitude0...2000 m
Ambient Air Temperature For Operation-25…60 °C
Ambient Air Temperature For Storage-40…85 °C
StandardsIEC 61010-2-201; IEC 61010-1
Packing Units12
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height3.300 cm
Package 1 Width6.500 cm
Package 1 Length37.000 cm
Package 1 Weight242.000 g
Unit Type Of Package 2S03
Number Of Units In Package 232
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.200 kg
Logistical informations1
Country Of OriginFR
Contractual warranty1
Warranty (in Months)18

Documents and Downloads

Documents are published by the manufacturer and open in a new tab.

Other Documents2

Tags

See products with the same tag in the catalogue.

WhatsApp Direct Support